To evaluate the effects of the ShotBlocker and vibration device on pain intensity and patient satisfaction during subcutaneous (SC) insulin injections in hospitalized adults with type 2 diabetes mellitus.
In this randomized controlled trial, 102 patients with type II diabetes mellitus were randomly assigned into 3 groups: 35 patients in the ShotBlocker group, 36 patients in the vibration group, and 31 patients in the control group. ShotBlocker was applied immediately before and during the injection, while the vibration was applied fo
: Porous silicon (n-PS) films can be prepared by photoelectochemical etching (PECE) Silicon chips n - types with 15 (mA /cm2), in15 minutes etching time on the fabrication nano-sized pore arrangement. By using X-ray diffraction measurement and atomic power microscopy characteristics (AFM), PS was investigated. It was also evaluated the crystallites size from (XRD) for the PS nanoscale. The atomic force microscopy confirmed the nano-metric size chemical fictionalization through the electrochemical etching that was shown on the PS surface chemical composition. The atomic power microscopy checks showed the roughness of the silicon surface. It is also notified (TiO2) preparation nano-particles that were prepared by pulse laser eradication in e
... Show MoreA modified chemical method was used to prepare titanium dioxide nanoparticles (TiO2 NPs), which were diagnosed by several techniques: X-ray diffraction, Fourier transform infrared, field emission scaning electron microscopy, energy disperse X-ray, and UV-visible spectroscopy, which proved the success of the preparation process at the nanoscale level. Where the titanium oxide particles have an average particle size equal to 6.8 nm, titanium dioxide particles were used in the process of adsorption of Congo red dye from its aqueous solutions using a batch system. The titanium oxide particles gave an adsorption efficiency of Congo red dye up to more than 79 %. The experimental data of the adsorption process were analyzed with kinetic models and
... Show MoreAim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a
... Show MoreBackground: One of the unique prosthesis for tooth or teeth replacement is the dental implant. Our attempt is using a biomaterial system that is easily obtained and applicable and has the ability to provoke osteoinductive growth factor to enhance bone formation at the site of application. One of these natural polymers is hyaluronic acid. Material and methods: Sixty machined surface implants from commercially pure titanium rod inserted in thirty NewZealand rabbits. Two implants placed in both tibia of each rabbit. The animals scarified at 1, 2 and 4 weeks after implantation (10 rabbits for each interval). For all of animals the right tibia’s implant was control (uncoated) and the left one was experimental (coated with 0.1ml Hyaluro
... Show MoreOrthodontic treatment has two major problems: being lengthy and costly procedure. The present study was designed to evaluate the clinical efficacy of locally injected vitamin D3 Keywords: Orthodontic, Calcitriol, Local injection, OTM (calcitriol) in accelerating orthodontic teeth movement (OTM) and reducing treatment time and cost in humans. The study was performed on 15 Iraqi adult orthodontic patients within the age range 17-28 years, they are randomly allocated into three groups, each of five patients and treated with either 15 pg, 25 pg, or 40 pg/0.2ml calcitriol diluted with 10% dimethylsulfoxide (DMSO). The maxillary arch of every patient was divided into control (right) and experimental (left) sides. In addition to force application,
... Show MoreMost dental works require a diagnostic impression; alginate is contemplated as the most popular material used for this purpose. Titanium dioxide nanoparticles show evidence of antimicrobial activity in the recent era, for this purpose, this study aimed to evaluate the effect of adding Titanium dioxide nanoparticles on antimicrobial activity and surface detail reproduction of alginate impression material. Materials and methods: Titanium dioxide nanoparticles (purity = 99%, size= 20nm) was added to alginate at three different concentrations (2%, 3% and 5%). 84 samples were prepared in total. Samples were tested for antimicrobial activity using a disc diffusion test, and surface detail reproduction was done using (ISO 21563:2021). One-way A
... Show MoreBackground: Stroke defined by diminished cerebral blood flow, results in brain damage and neurological impairments. It often leads to considerable difficulties, such as limited mobility and compromised hand function, usually manifesting as a weakening in the ability to open and shut the hand. Objective: The study evaluates the differences between opening and closing hands when utilizing a soft robot. Methods: The study was conducted in the Mosul Specialist Rehabilitation Center which involved 68 participants, all over 20 years old, with visual impairments. The Iranian Clinical Trials Registry and Ministry of Planning approved the study, The Fugl-Meyer Assessment for Upper Extremity Action Research Arm Test, and Arm Motor Ability Test were
... Show More