Preferred Language
Articles
/
CRacDIcBVTCNdQwC5jM9
Performance evaluation of asphalt concrete mixes under varying replacement percentages of natural sand
...Show More Authors

Frequently, load associated mode of failure, rutting and fatigue, are the main failure types found in some newly constructed roads within Baghdad, the capital of Iraq, and some suburban areas. The use of excessive amount of natural sand in asphalt concrete mixes which is attractive to local contractors could be one of the possible causes to the lack of strength properties of the mixes resulting in frustration in the pavement performance. In this study, the performance properties of asphalt concrete mixes with two natural sand types, desert and river sands, were evaluated. Moreover, five replacement rates of 0, 25, 50, 75, and 100% by weight of the fine aggregate finer than 4.75 were used. The performance properties including moisture susceptibility, resilient modulus, permanent deformation, and fatigue characteristics were evaluated using indirect tensile strength, uniaxial repeated loading and repeated flexural beam tests. Also, as a part of the research objective, the laboratory tests result were used to predict the performance using VESYS computer software. Results showed that mixes with high natural sand content (NSC) are more susceptible to moisture damage and rutting, lower resilient modulus and some improvement in fatigue resistance. Based on the obtained results, the necessity has rise to revise the current local specification for asphalt concrete which specifies the limits of natural sand content in the mixes of wearing and binder courses with 25% whereas for base course mixes no limit exist yet.

Crossref
View Publication
Publication Date
Sat Oct 31 2020
Journal Name
International Journal Of Integrated Engineering
Behavior of High Strength Hybrid Reinforcement Concrete Beams
...Show More Authors

Six proposed simply supported high strength-steel fiber reinforced concrete (HS-SFRC) beams reinforced with FRP (fiber reinforced polymer) rebars were numerically tested by finite element method using ABAQUS software to investigate their behavior under the flexural failure. The beams were divided into two groups depending on their cross sectional shape. Group A consisted of four trapezoidal beams with dimensions of (height 200 mm, top width 250 mm, and bottom width 125 mm), while group B consisted of two rectangular beams with dimensions of (125 ×200) mm. All specimens have same total length of 1500 mm, and they were also considered to be made of same high strength concrete designed material with 1% volume fraction of steel fiber.

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Jan 10 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Influence of Accelerated Curing on Fiber Reinforced Concrete
...Show More Authors

The adopted accelerated curing methods in the experimental work are 55ºC and 82ºC according to British standard methods. The concrete mix with the characteristics compressive strength of 35MPa is design according to the ACI 211.1, the mix proportion is (1:2.65:3.82) for cement, fine and coarse aggregate, respectively. The concrete reinforced with different volume fraction (0.25, 0.5 and 0.75)% of glass, carbon and polypropylene fibers. The experimental results showed that the accelerated curing method using 82ºC gives a compressive strength higher than 55ºC method for all concrete mixes. In addition, the fiber reinforced concrete with 0.75% gives the maximum compressive strength, flexural and splitting tensile strength for all types of

... Show More
View Publication
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Strength of Reinforced Concrete Columns with Transverse Openings
...Show More Authors

The present work is concerned with the investigation of the behavior and ultimate capacity of axially loaded reinforced concrete columns in presence of transverse openings under axial load plus uniaxial bending. The experimental program includes testing of twenty reinforced concrete columns (150 × 150 × 700 mm) under concentric and eccentric load. Parameters considered include opening size, load eccentricity and influence of the direction of load eccentricity with respect to the longitudinal axis of the opening. Experimental results are discussed based on load – lateral mid height deflection curves, load – longitudinal shortening behavior, ultimate load and failure modes. It is found that when the direction of load

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 03 2025
Journal Name
Engineering, Technology & Applied Science Research
Behavior of Glass Fiber Reinforced Polymer Concrete Panels
...Show More Authors

Glass Fiber Reinforced Polymer (GFRP) bars have gained popularity as a corrosion-resistant alternative to traditional steel reinforcement in Reinforced Concrete (RC) elements. This study investigates the flexural behavior of PRC panels reinforced with GFRP bars. The study variables included the GFRP reinforcement ratio and the number of embedded steel section distributions. Six concrete panels were fabricated, each measuring 2500 mm in length, with a rectangular cross-section of 750 mm in width and 150 mm in thickness. All panels were reinforced with GFRP bars and divided into two groups based on the reinforcement ratios of 0.532% and 0.266%. For each group, one panel served as the control specimen, while the remaining two were inte

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Engineering
Strengthening of GFRP Reinforced Concrete Slabs with Openings
...Show More Authors

Using fiber-reinforced polymer (FRP) could effectively improve the strength and endurance of reinforced concrete (RC) constructions. This study evaluated the flexural behavior of one-way concrete slabs with openings reinforced with glass fiber-reinforced polymers (GFRP) bars. It strengthened using carbon fiber-reinforced polymer (CFRP) sheets around the openings. The experimental program of this study is adopted by casting and testing four one-way concrete slabs with dimensions of (150*750*2650) mm. These slabs are divided into two groups based on whether they were strengthened or un-strengthened. For each group, two different openings (either one rectangular or two square) measured 250*500 mm and 250*250 mm, respective

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
Direct Shear Behavior of Fiber Reinforced Concrete Elements
...Show More Authors

Improving the accuracy of load-deformation behavior, failure mode, and ultimate load capacity for reinforced concrete members subjected to in-plane loadings such as corbels, wall to foundation connections and panels need shear strength behavior to be included. Shear design in reinforced concrete structures depends on crack width, crack slippage and roughness of the surface of cracks.

This paper illustrates results of an experimental investigation conducted to investigate the direct shear strength of fiber normal strength concrete (NSC) and reactive powder concrete (RPC). The tests were performed along a pre-selected shear plane in concrete members named push-off specimens. The effectiveness of concrete compressiv

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
The Bourgeois ascendancy under Fatimids
...Show More Authors

The bourgeoisie groups derived great advantages from the system upon which the Fatimids built up their Regime out the land-tax and other taxes against a fixed sum . The surpulus revenue was the prophet of the farmers . A striking feature of the Fatimid was freedom of enterprise .All sectors of economic life were free-crafts , industry and trade . The government interfered in the trade in victuals only so far to in order to guarantee the supply of wheat to the big towns
The Egyptian Bourgeoisie enjoyed also the great prosperity which was produced among other reasons by the inflationary system of Fatimid economy .
The maintenance of gold dinar being almost pure and of full weight was only possible because Egypt steadily received cons

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2022
Journal Name
Journal Of Economics And Administrative Sciences
An Evaluation of Environmental Performance According to The International Standard (ISO14001: 2015) in a Field East of Baghdad / A Case Study in the Midline Oil Company
...Show More Authors

EMS in accordance with ISO 14001: 2015 is considered an entry point to reduce environmental impacts, especially the effects resulting from the oil industry, which is the main source of environmental pollution and waste of natural resources, since the second revision of the standard took place in September 2015. The problem of the research was manifested in the weakness in understanding the correct guidelines that must be followed in order to obtain and maintain the standard. The purpose of this research was to give a general picture of what is behind ISO14001:2015 and how it is possible to create a comprehensive base for understanding its application by seeking the gap between the actually achieved reality, standards requirements

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2021
Journal Name
Journal Of Engineering
Performance Evaluation of Pole Placement and Linear Quadratic Regulator Strategies Designed for Mass-Spring-Damper System Based on Simulated Annealing and Ant Colony Optimization
...Show More Authors

This paper investigates the performance evaluation of two state feedback controllers, Pole Placement (PP) and Linear Quadratic Regulator (LQR). The two controllers are designed for a Mass-Spring-Damper (MSD) system found in numerous applications to stabilize the MSD system performance and minimize the position tracking error of the system output. The state space model of the MSD system is first developed. Then, two meta-heuristic optimizations, Simulated Annealing (SA) optimization and Ant Colony (AC) optimization are utilized to optimize feedback gains matrix K of the PP and the weighting matrices Q and R of the LQR to make the MSD system reach stabilization and reduce the oscillation of the response. The Matlab softwar

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Feb 26 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Role of Managerial Accounting Information System in Improving the Value Chain and its Impaction Evaluation Performance: دراسة حالة في الشركة العامة لصناعة الزيوت النباتية
...Show More Authors

The performance measures and traditional methods used in management accounting is no longer able to provide convenient to evaluate the performance of economic units in the modern manufacturing environment information، and so this information is more important and feasibility must be Mistohat of all the company's activities and functions، and it is a problem Find the inadequacy of information management accounting that contribute to meet the needs of the upper levels of management to cope with the problems resulting from the increased size and complexity of the business، and lack of management accounting information and methods used in the performance evaluation، which reflected negatively on the value chain activities and then on the

... Show More
View Publication Preview PDF
Crossref