Preferred Language
Articles
/
CEJVZZoBMeyNPGM3zsHp
The effect of thermocycling on fracture resistance of zirconia crowns cemented with polylysine modified resin cements (Comparative in vitro study)
...Show More Authors

ABSTRACT Background: resin cement type and intraoral temperature fluctuations may affect the fracture performance of successful zirconia restorations. To fill this gap, the purpose of this study is to evaluate and compare the influence of thermocycling on fracture resistance and mode of failure of monolithic zirconia crowns luted with Rely X™ U200 and BreezeTMself-adhesive resin cements as well as imply the effect of adding 2 % of polylysine (PLS) to these cements. Materials: 64 maxillary premolars were milled out of zirconia blocks using CAD/CAM milling system. They were divided into four groups (n = 16) according to the cement type. Four different resin cements were used (RelyXTMU200, Breeze™, RelyX™ U200 with 2 % PLS and Breeze™ with 2%PLS). Each group was further subdivided into experimental and control groups (n = 8). The experimental specimens were exposed to thermocycling protocol of 10,000 cycles in water bath at 5 ◦C and 55 ◦C.Each specimen was subjected to axial load until fracture using universal testing machine. Fracture modes were analyzed using digital microscope. Data were statistically analyzed using paired t-test at a level of significance of 0.05. Results: there was a statistical significant difference in fracture load among groups (p < 0.05) with the highest mean in Rely X cement. Although the fracture loads statistically decreased after thermocycling (p < 0.05) there was no significant effect on the addition of 2 % PLS (p > 0.05). Microscopical analysis demonstrated a majority of catastrophic mode of fracture. Conclusion: both cement type and thermocycling exert significant effects on fracture resistance of premolars crowns restored with monolithic zirconia, while the addition of 2 % PLS exerted negligible effec

Crossref
View Publication
Publication Date
Sun Nov 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different polishing systems on the surface roughness of full-contour zirconia
...Show More Authors

Background: Adjustment of any premature occlusal contact of any zirconia restoration requires its polishing or glazing in order to restore the smoothness of the restoration. The objective of this in vitro study was to evaluate the effects of different polishing systems and glazing on the surface roughness of full-contour zirconia. Material and methods: Forty disks (diameter: 8 mm, thickness: 6.4 mm) were prepared from pre-sintered full-contoured zirconia block; they were colored and sintered in a high-temperature furnace at 1500ËšC for 8 hours. The specimens were then leveled and finished using grinding and polishing machine and adjusted using diamond disk. The specimens were then randomly divided into four groups (n=10), group I involves

... Show More
View Publication Preview PDF
Publication Date
Mon May 29 2023
Journal Name
Rawal Medical Journal
Comparative prospective study of knee pain in medial pararpatellar and transpatellar entry for interlocking nail fixation of tibia fracture
...Show More Authors

Objective: To compare two insertion techniques of intramedullary interlocking nails (medial parapatellar versus intrapatellar insertion) in patients with tibial fractures. Methodology: This study was performed at Al-Kindy Teaching Hospital from August 2020 until March 2022. All 32 patients with tibial fractures (29 males and 3 females) were included for tibial closed nail fixation and then followed up for 6 months. We categorized these patients into two groups; Group A (16 patients), those treated by medial parapatellar insertion of an interlocking nail, and Group B (16 patients) with transpatellar tibial nail insertion. All patients were treated by the same surgical team. Results: The range of movement in two weeks (from extension

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Jul 01 2025
Journal Name
Minerva Dental And Oral Science
Evaluation of the microleakage of new bioactive restorative materials: a comparative in-vitro study
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Nov 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of ER: YAG laser on apical microleakage (in vitro study)
...Show More Authors

Background: Apicoectomy and retrograde filling is indicated when conventional endodontic treatment is impossible or failed to achieve apical seal. The aim of this study was to evaluate the effect of ER: YAG laser on apical microleakage. Materials and Methods: Sixty extracted single-rooted teeth were used in this study. The roots were divided into six groups. Group 1: apicoectomy by fissure bur, and apical cavities prepared by round bur, then cavities were filled with MTA. Group 2: the roots preparations and fillings were the same as group 1, then the apical areas were treated by Er:YAG Laser. Group 3: apicoectomy by fissure bur, and apical cavities prepared by ultrasound retrotip and cavities were filled with MTA. Group 4: the roots prepara

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative Assessment of In Vitro Effect of Three Fluoride Releasing Agents on Enamel Demineralization around Orthodontic Brackets
...Show More Authors

Background: White spot lesion considered as irreversible tooth demineralization presenting challenge to orthodontists during treatment schedules, fluoride was the most successfully used measure to overcome this challenge. Materials and method: A total of forty sound human permanent premolars were used in the present study and categorized into four groups, in one group the teeth were bonded with stainless steel brackets using Resin-modified glass ionomer cement (RMGIC) and the other three groups the teeth were bonded with light cured composite Resilience® (Ortho technology Co., USA). Group A; Acidulated phosphate fluoride (APF) topical gel (Mfg by DEEPAK PRODUCTS, INC, USA), fluoride ion 1.23% applied on examine area for four minute. Gro

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative Assessment of in Vitro Effect of Three Fluoride Releasing Agents on Enamel Demineralization around Orthodontic Brackets
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
The effect of additives metal on the D.C conductivity of epoxy resin
...Show More Authors

The present studies are focused on the modification of the properties of epoxy resin with different additives namely aluminum, copper by preparing of composites systems with percentage (20%, 40% and 50%) of the above additives. The experimental results show that the D.C of conductivity on wt% filler content at ( 293-413 ) K electrical conductivity of all above composites increased with temperature for composites with filler contact and find the excellent electrical conductivity of copper and lie between (2.6*10-10 - 2.1*10-10)?.cm . The activation energy of the electrical conductivity is determined and found to decrease with increasing the filler concentration.

View Publication Preview PDF
Crossref
Publication Date
Sun Nov 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effects of various beverages on the shear bond strength of light-cured orthodontic composite (An in vitro comparative study)
...Show More Authors

Background: This study was conducted to assess the effects of various beverages on the shear bond strength of light-cured orthodontic composite used to bond stainless steel orthodontic brackets on human teeth and to determine the site of bonding failure of this material. Materials and Methods: Fifty extracted human premolars were selected and randomly divided into five equal groups each with 10 teeth according to the beverage type (Control, One Tiger, Milk, Green tea and Coffee). After bonding, the teeth were immersed in specific beverages for 5 minutes twice daily with equal intervening intervals then washed and stored in distilled water at 37º C for the reminder of the day. The process was carried out for 30 days. The samples were then

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Effect of Thermocycling on Surface Roughness and Shear Bond Strength of Acrylic Soft Liner to the Surface of Thermoplastic Acrylic Treated with Ethyl Acetate
...Show More Authors

Objective: To enhance bonding strength between thermoplastic denture base and acrylic soft liner through ethyl acetate surface treatment. Materials and Methods: Modifications of thermoplastic acrylic denture base surface were investigated with SEM. FTIR was used to detect whether there was a chemical bond between thermoplastic acrylic and the organic solvent. A total of 80 samples were prepared and divided into 20 samples for the surface roughness test and 60 samples for the shear bond strength test. Failure type was assessed visually. Results: Shear bond strength and surface roughness values of un treated samples were lower in comparison to surface treated groups; the greatest post thermocycling bond strength value was recorded for the sam

... Show More
Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Comparative Assessment Of The Effect Of Gutta-Fusion Obturation On The Push Out Bond Strenght Of Three Types Of Sealers
...Show More Authors

Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in

... Show More
View Publication Preview PDF
Crossref (2)
Crossref