Preferred Language
Articles
/
C4YoroYBIXToZYAL5aR3
Assessment of Water Quality in Tigris River of AL-Kut City, Iraq by Using GIS
...Show More Authors

The concerns about water contaminants affect most developing countries bypassing rivers over them. The issue is challenging to introduce water quality within the allowed limits for drinking, industrial and agricultural purposes. In the present study, physical-chemical parameters measurements of water samples taken from eleven stations were collected during six months in 2020 through flow path along the whole length of Tigris River inside AL Kut city (center of Wassit government) were investigated for six parameters are total hardness TH, hydrogen ion pH, biological oxygen demand BOD5, total dissolved solids TDS, nitrate NO3, and sulfate SO4. The water quality analysis results were compared with the maximum allowable limit concentration recommended by World Health Organization WHO and Iraqi limitation spastically; TH, BOD5, TDS, and SO4 had an average value of 421, 62, 813, and 376 mg/l, respectively. The spatial distribution of six water quality parameters within the studied area was carried out by implementing the Quantum Geography Information System QGIS technique established on the Inverse Distance Weighted IDW method to produce the interpolation predicted maps of stations along the river in Al Kut city. The results showed water quality degraded and an increase in the concentrations observed for all parameters along the river path, especially at the last two stations due to attributed to human activities, land use and industrialization, and outfall of sewerage flow to the river directly without treatment. Spatial distribution is essential to give a thorough understanding of the river's contamination reality. This makes it easier to understand, analyze and find the appropriate treatments and solutions to the problem of water quality.

Scopus Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
The Leaching Behavior of Zinc Oxide in Medical Waste of Dental Clinics
...Show More Authors

Zinc Oxide is an indispensable substance in the field of dental treatment. It is used daily and intensively in all governmental and private dental clinics, leading to the disposal of very high concentrations of zinc with waste and eventually in landfill sites as a final destination for solid waste removal. This indicates the urgent need to investigate its behavior upon disposal due to the surrounding conditions. Approximately 4195 g of mixed dental waste samples were collected from (17) healthcare centers in Baghdad Al-Karkh. The leaching behavior of ZnO powder was investigated through batch reactors using makeup dental solid waste samples. The ZnO leaching was tested with 3 conditions; acidic, alkaline, and Ionic Streng

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Sep 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Problems of Heavy Oil Transportation in Pipelines And Reduction of High Viscosity
...Show More Authors

Drag has long been identified as the main reason for the loss of energy in fluid transmission like pipelines and other similar transportation channels. The main contributor to this drag is the viscosity as well as friction against the pipe walls, which will results in more pumping power consumption.

   The aim in this study was first to understand the role of additives in the viscosity reduction and secondly to evaluate the drag reduction efficiency when blending with different solvents.

   This research investigated flow increase (%FI) in heavy oil at different flow rates (2 to 10 m3/hr) in two pipes (0.0381 m & 0.0508 m) ID By using different additives (toluene and naphtha) with different concent

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of operation conditions on Catalytic Oxidation of Phenol in Aqueous Solution
...Show More Authors

This work was conducted to study the oxidation of phenol in aqueous solution using copper based catalyst with zinc as promoter and different carrier, i.e. γ-Alumina and silica. These catalysts were prepared by impregnation method.
The effect of catalyst composition, pH (5.6-9), phenol to catalyst concentration ratio (2-0.5), air feed rate (30-50) ml/s, stirring speed (400-800) rpm, and temperature (80-100) °C were examined in order to find the best conditions for phenol conversion.
The best operating conditions which lead to maximum phenol conversion (73.1%) are : 7.5 pH, 4/6 phenol to catalyst concentration, 40 ml/s air feed rate, 600 rpm stirring speed, and 100 °C reaction temperature. The reaction involved an induction period

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 30 2026
Journal Name
Ishraqat Tanmawia
Formation Engineering and Pedagogy of E-Learning in Light of Corona Pandemic
...Show More Authors

View Publication
Publication Date
Wed Mar 16 2016
Journal Name
World Journal Of Pharmaceutical Research
Identification of some species of wireworm Agriotes spp.(Coleoptera: Elateridae) in Baghdad
...Show More Authors

Publication Date
Sat Jan 02 2021
Journal Name
International Journal Of Pharmaceutical Research
Detection of Kaposi’s Associated Herpesvirus in Saliva of Drug Related Immunosupressed Patient
...Show More Authors

View Publication
Crossref
Publication Date
Thu May 03 2001
Journal Name
Master's Thesis
The image of the United States of America in the Iraqi press
...Show More Authors

Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Effect of pesticide Glyphosate Aqua in liver enzymes activity of Barbus sharpeyi
...Show More Authors

The present study was designed in the aquaculture and fish nutrition research aquarium in the College of Veterinary Medicine/Baghdad University from a period 1/3 to 1/6/2013 to investigate the toxicity of the herbicide glyphosate aqua on Barbus sharpeyi fish. Fish fingerlings were used with average weight between 10 – 15 gm to measure the (LC50), and 200 fingerlings were used to know the acute and chronic toxic effect for the herbicide. The fingerlings were randomly distributed as 10 fish for each aquarium. Fish were divided into four treatments and control group (without addition of herbicide). The first processing with a concentration of 0.415 mg/L for a duration of exposure 90 days, the second processing group with a concentration 0.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Bioequivalence and Pharmacokinetics of Two Formulations of Amlodipine Tablets in Healthy Subjects
...Show More Authors

The bioequivalence of a single dose tablet containing 5 mg amlodipine as a test product in comparison to Norvasc® 5 mg tablet (Pfizer USA) as the reference product was studied. Both products were administered to twenty eight healthy male adult subjects applying  a fasting, single-dose, two-treatment, two-period, two-sequence, randomized crossover design with two weeks washout period between dosing. Twenty blood samples were withdrawn from each subject over 144 hours period. Amlodipine concentrations were determined in plasma by a validated HPLC-MS/MS method. From the plasma concentration-time data of each individual, the pharmacokinetic parameters; Cmax, Tmax, AUC0-t, AUC0-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
The Efficacy of (810 Nm) Diode Laser in Treatment of Idiopathic Epistaxis
...Show More Authors

There are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one

... Show More
View Publication Preview PDF