A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS), pH (8) and Elution solvent used is methanol. The water samples to be analyzed were taken from six different locations. Three of them inside the station of petroleum refinery waste water treatment unit and the other three were at the Tigris River in Iraq around the station. The results were between (non detected, 246.9) µg/L inside the station and (non detected, 288.7) µg/L at the river.
The research deals with the principle of the prohibition of international waterway diversion in the law of international watercourses. The research reviews individual and collective doctrinal efforts that have touched upon the principle as an internationally wrongful act because of its serious damage and consequences for downstream States. The research addresses the nature of the principle of the prohibition of diversion of international watercourses; its various effects; principles of international law establishing the principle of prohibition of diversion; and its application in State practice and international justice. This principle has been enshrined in most international treaties and judicial decisions. The principle of prohibition
... Show MoreA simple, environmentally benign, cost-effective, and sensitive colorimetric determination for the pharmaceutical drug dexamethasone sodium phosphate (DXP) has been developed by the formation of a colored complex with fluoranil. The process was sensitive and linear over the range 1 to 40 μg/mL, excellent correlation coefficient 0.9989, recovery% 99.80 ± 1.3, limit of detection (LOD) and limit of quantification (LOQ) were 0.23 and 0.9 μg/mL, respectively, and good RSD ~1.63%. The experimental conditions were optimized after an intensive study. The approach was validated statistically for the quantification of the analyte in its pure and/or pharmaceutical form. Despite the proposed approach is selective, it still can be applied for
... Show MoreObjective: The study aimed to determine quality of life domains for adult patients with limbs loss and to identify
the association between quality of life domains and demographic characteristics and medical information.
Methodology: A descriptive study was carried out at Baghdad artificial limb center, Al-Salam medical
rehabilitation center, Al-Ghadeer medical rehabilitation center and the rheumatoid and medical rehabilitation
center for the period from September 2007 to April 2008. A purposive ''non- probability'' sample of (200)
patients with limbs loss. Questionnaire form was constructed for the purpose of the study. Data were collected
through the application of the questionnaire and interview technique. Data were a
The aim of this paper is to determine the feasibility of using fluorometric methods as an indicator for quality and contamination of milk with E.coli bacteria, and selection the suitable wavelength to be used with laser induced auto fluorescence. Three groups of milk samples were used in this study: Fresh pasteurized milk samples, milk samples containing different concentration of E.coli bacteria which were added artificially, and milk samples that were kept in refrigerator for 3-5 days. Thirteen excitation wavelengths were used to get the emission spectra for all milk samples using spectroflourometer .The results showed that the emission spectra at 275nm excitation wavelength gave a good differentiation between these three groups.
... Show MoreModeling the microclimate of a greenhouse located in Baghdad under its weather conditions to calculate the heating and cooling loads by computer simulation. Solar collectors with a V-corrugated absorber plate and an auxiliary heat source were used as a heating system. A rotary silica gel desiccant dehumidifier, a sensible heat exchanger, and an evaporative cooler were added to the collectors to form an open-cycle solar assisted desiccant cooling system. A dynamic model was adopted to predict the inside air and the soil surface temperatures of the greenhouse. These temperatures are used to predict the greenhouse heating and cooling loads through an energy balance method which takes into account the soil heat gain. This is not included in
... Show MoreIn this research, Artificial Neural Networks (ANNs) technique was applied in an attempt to predict the water levels and some of the water quality parameters at Tigris River in Wasit Government for five different sites. These predictions are useful in the planning, management, evaluation of the water resources in the area. Spatial data along a river system or area at different locations in a catchment area usually have missing measurements, hence an accurate prediction. model to fill these missing values is essential.
The selected sites for water quality data prediction were Sewera, Numania , Kut u/s, Kut d/s, Garaf observation sites. In these five sites models were built for prediction of the water level and water quality parameters.
In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended
use as well as indicating pollution, which are useful in water quality management and decision making. The application of Water Quality Index (WQI) with ten physicochemical water quality parameters was performed to evaluate the quality of Euphrates River water for drinking usage. This was done by subjecting the water samples collected from seven stations within Al-Anbar province during the period 2004-2010 to comprehensive physicochemical analysis. The ten physicochemical paramete
During the study the current selection seven stations in the Zab River bottom and the Tigris River took samples a month to study the signs of bacterial contamination study coliform and colon fecal Almsobhaat and Almsobhaat Bazah and the total number of bacteria and bacterial gangrene gas causing Knkeran as well as a study to isolate and diagnose some races and types of bacterial pathogens in water or intensityusing the traditional system and the system of intestinal bacteria
In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, water quality management and decision making. The application of Water Quality Index
(WQI) with sixteen physicochemical water quality parameters was performed to evaluate the quality of Tigris River water for drinking usage. This was done by subjecting the water samples collected from eight stations in Baghdad city during the period 2004-2010 to comprehensive physicochemical analysis. The sixteen physicochemical parameters included: Turbidity, A
In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, which are useful in water quality management and decision making. The application of Water Quality Index (WQI) with ten physicochemical water quality parameters was performed to evaluate the quality of Euphrates River water for drinking usage. This was done by subjecting the water samples collected from seven stations within Al-Anbar province during the period 2004-2010 to comprehensive physicochemical analysis. The ten physicochemical parame
... Show More