Preferred Language
Articles
/
BhfabZIBVTCNdQwCC7Bt
An enemy hides in the ceiling; pediatric traumatic brain injury caused by metallic ceiling fan: Case series and literature review
...Show More Authors

Purpose: We report a series of 29 pediatric patients who sustained head injuries due to metallic ceiling fans. They all were admitted to the Emergency Department of Neurosurgery Teaching Hospital in Baghdad, Iraq, during January 2015 to January 2017. Results: Pediatric ceiling fan head injuries are characterized by four traits which distinguish them from other types of head injuries; 1- Most of them were because of climbing on or jumping from furniture between the ages of two and five. 2- Most of them sustained compound depressed skull fracture which associated with intracranial lesions and pneumocephalus. 3- The most common indication for surgical intervention was because of dirty wound which mixed with hairs. 4- These variables were statistically significantly correlated with the outcome: Level of consciousness, neurologic deficit, fracture site (occipital fracture had worse outcome), intracranial hemorrhage and surgery. Conclusion: Pediatric metallic ceiling fan head injury should be seen as a distinct type of head injury because it has special presentations, managements, and outcomes. In addition, we should start applying preventive methods to minimize its occurrence.

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION
...Show More Authors

Several industrial wastewater streams may contain heavy metal ions, which must be effectively removal
before the discharge or reuse of treated waters could take place. In this paper, the removal of copper( II)
by foam flotation from dilute aqueous solutions was investigated at laboratory scale. The effects of
various parameters such as pH, collector and frother concentrations, initial copper concentration, air flow
rate, hole diameter of the gas distributor, and NaCl addition were tested in a bubble column of 6 cm inside
diameter and 120 cm height. Sodium dodecylsulfate (SDS) and Hexadecyl trimethyl ammonium bromide
(HTAB) were used as anionic and cationic surfactant, respectively. Ethanol was used as frothers and the

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Proximal schemes by family of szl –widering mappings
...Show More Authors
Abstract<p>in this paper, we give a concept of <italic>szl</italic> –widering mapping which is independent of nonspreading mappings, <italic>k</italic> – strictly pseudo nonspring mappings and nonexpansive mappings. Also we introduce a new proximal point schemes of resolvent and <italic>szl</italic> –widering mappings. On the other hand, we discuss that the weak and strong convergence for these proximal point schemes in real Hilbert space under different conditions to asymptotic common fixed point of <italic>szl</italic> –widering mappings.</p>
View Publication
Scopus (5)
Scopus Crossref
Publication Date
Wed Feb 01 2017
Journal Name
Journal Of Multidisciplinary Engineering Science Studies
Investigation of p-Ps Produced by Electrochemical Etching
...Show More Authors

The nanocrystalline porous silicon (PS) films are prepared by electrochemical etching ECE of p -type silicon wafer with current density (10mA/cm ) and etching times on the formation nano -sized pore array with a dimension of around different etching time (10 and 20) min. The films were characterized by the measurement of XRD, atomic force microscopy properties (AFM). We have estimated crystallites size from X -Ray diffraction about nanoscale for PS and AFM confirms the nanometric size Chemical fictionalization during the electrochemical etching show on the surface chemical composition of PS. The atomic force microscopy investigation shows the rough silicon surface, with increasing etching process (current density and etching time) porous st

... Show More
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Diagnosing Pilgrimage Common Diseases by Interactive Multimedia Courseware
...Show More Authors

In this study, we attempt to provide healthcare service to the pilgrims. This study describes how a multimedia courseware can be used in making the pilgrims aware of the common diseases that are present in Saudi Arabia during the pilgrimage. The multimedia courseware will also be used in providing some information about the symptoms of these diseases, and how each of them can be treated. The multimedia courseware contains a virtual representation of a hospital, some videos of actual cases of patients, and authentic learning activities intended to enhance health competencies during the pilgrimage. An examination of the courseware was conducted so as to study the manner in which the elements of the courseware are applied in real-time learn

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Kinetic of Disinfection reaction by Sodium Hypochlorite Solution
...Show More Authors

The present studier aims to study the kinetic of reaction at different experimental conditions depending on coliform bacteria concentration and hypochlorite ion. The effects that had been investigated were different of sodium hypochlorite doses, contact time, pH and temperature (20, 29, 37) o C. The water samples were taken from Al-Wathba water treatment plant in Risafa side of Tigris River in Baghdad. The biological tests included the most probable number (M.P.N) for indicating the concentration of coliform bacteria with different contact times and the total plate count (T.P.C) for indicating the amount of colonies for general bacteria. The iodimetry method (chemical test) was used for indicating the concentration of hypochlo

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 31 2024
Journal Name
Journal Of Optics
Novel characteristics of CQDs synthesized by electrochemical method
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
International Journal Of Agricultural And Statistical Sciences
ESTIMATING NONPARAMETRIC AUTOREGRESSIVE CURVE BY SMOOTHING SPLINES METHOD
...Show More Authors

Preview PDF
Scopus
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Reducing Lost Circulation Problem by Using Rice Material
...Show More Authors

Drilling fluid loss during drilling operation is undesirable, expensive and potentially hazardous problem.

    Nasiriyah oil field is one of the Iraqi oil field that suffer from lost circulation problem. It is known that Dammam, um-Radoma, Tayarat, Shiranish and Hartha are the detecting layers of loss circulation problem. Different type of loss circulation materials (LCMs) ranging from granular, flakes and fibrous were used previously to treat this problem.  

    This study presents the application of rice as a lost circulation material that used to mitigate and stop the loss problem when partial or total losses occurred.

     The experim

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Emulsified Kerosene from Water by Flotation
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
LEAD Removal from Industrial Wastewater by Electrocoagulation process
...Show More Authors

This investigation was carried out to study the treatment and recycling of wastewater in the Battery industry for an effluent containing lead ion. The reuse of such effluent can only be made possible by appropriate treatment method such as electro coagulation.
The electrochemical process, which uses a cell comprised aluminum electrode as anode and stainless steel electrode as cathode was applied to simulated wastewater containing lead ion in concentration 30 – 120 mg/l, at different operational conditions such as current density 0.4-1.2 mA/cm2, pH 6 -10 , and time 10 - 180 minute.
The results showed that the best operating conditions for complete lead removal (100%) at maximum concentration 120 mg/l was found to be 1.2 mA/cm2 cur

... Show More
View Publication Preview PDF