In this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. In order to investigate the response of soil and footing to steady state dynamic loading, a physical model was manufactured. The manufactured physical model could be used to simulate steady state harmonic load at different operating frequencies. Total of (84) physical models were performed. The parameters that were taken into considerations include loading frequency, size of footing and different soil conditions. The footing parameters were related to the size of the rectangular footing and depth of embedment. Two sizes of rectangular steel model footing were used (100 200 12.5 mm) and (200 400 5.0 mm). The footing was tested in all parameters at the surface and at 50 mm depth below model surface. Meanwhile the investigated parameters of the soil condition included dry and saturated sand for two relative densities 30% and 80%. The response of the soil to dynamic loading includes measuring the stresses inside the soil using piezoelectric sensors as well as measuring the excess pore water pressure by using pore water pressure transducers. It was found that the rate of increase in excess pore water pressure ratio decreased remarkably at a depth of 0.5 B–1.5 B (B is the footing width) for medium and loose dense sand, respectively. Moreover, excess pore water pressure ratio increases with increasing the eccentricity of dynamic load. The generated pore water pressure is always greater under the point of load application. Its value reduces with a certain percentages at any point away from the point of load application. In addition, the rate of variation of pore water pressure with eccentricity for loose sand is less than that for medium dense sand. The dynamic stress increments resulting from the dynamic load on the foundation reduce with depth. In addition, the dynamic stresses under the corner are slightly greater than the stresses at the center by a percentage of about 10.0%. The excess pore water pressure increases with increasing the relative density of the sand, the amplitude of dynamic loading and the operating frequency. In contrast, the rate of dissipation of the excess pore water pressure during dynamic loading is more in the case of loose sand.
The vacancy of natural resources is undoubtedly limited by time. The sustainable development principle recommends modern technology for its protection and renewal. This project conducted analyses on two underground water sources in the north of Algeria (Mechroha Province). Besides, the use of the hardness factor and the adoption of the titration method, which is the determining the concentration of an unknown solution using a known solution concentration, have permitted the characterization of the examples taken and to verify their conformity to the standard required, the results found showed HT=6.66 French degrees (oF) ) for Ain Guilloume water spring in comparison to Ain Messai water spring H
Furfural is one of the one of pollutants in refinery industrial wastewaters. In this study advanced oxidation process using UV/H2O2 was investigated for furfural degradation in synthetic wastewater. The results from the experimental work showed that the degradation of furfural decreases as its concentration increases, reaching 100% at 50mg/l furfural concentration and increasing the concentration of H2O2 from 250 to 500 mg/l increased furfural removal from 40 to 60%.The degradation of furfural reached 100% after 90 min exposure time using two UV lamps, where it reached 60% using one lamp after 240 min exposure time. The rate of furfural degradation k increased at the pH and initial concentratio
... Show MoreThe current research involves psychological pressure (educational,environment andemotionly) for secondary level to 2013-2014.This research includes comparison among students who are trained and not trained in physical education .The sample is(126) students from each gender from first education.Al-Karkh and the research found out that physical education has an effect in lessing emotional and educational in a big degree in student in secondary which affect them positively in their study. &n
... Show MoreFlavonoids are known to play a vital role in the management of various liver disorders.They are a large family of compounds synthesized by plants; they belong to a group of natural substances with variable phenolic structures. In this study we aim to scan the types of flavonoids in a newly studied, wild Iraqi plant named Echinops tenuisectus of Compositae family. The medicinal importance of flavonoids on one hand, and the absence of any phytochemical investigation on tenuisectus species of Echinops genus on the other hand, acquired this study itÛ¥s importance. Three flavonoids were identified in the seed,s extract of this plant (Silymarin, Rutin, Quercetin ) by two chromatographic methods, first Thin laye
... Show MoreAsthma is a chronic respiratory disorder in which immunological and structural cells play a role. The limits of conventional medicines necessitate the development of innovative therapeutic techniques for asthma. In the present study, we investigated the possible protective effect of cinnamic acid (CA) on ovalbumin-induced asthma in a mouse model. Sixty albino male mice BALB/c type weighing (20-30) grams were chosen at random and divided into five groups each one contains 12 animal: Group I: PBS/liquid paraffin control. Group II: asthma model group. Group III: cinnamic acid control group; mice received cinnamic acid (50 mg/kg) in liquid paraffin orally by gavage. Group IV: asthma model / group of (25 mg / kg) cinnamic acid; mice received
... Show MoreThis study aimed to investigate the effect of water treated with a magnetic field with different induction on the histological structure of the kidney and testicular tissue of albino rats. For this purpose, fifty albino rats were divided into five equal groups, the first of which was used as a control group, drank clean tap water for four weeks, the other groups were given daily water treated with a magnetic field with an induction of 500, 1000, 1500 and 2000 gauss. Then the animals were sacrificed and histological changes in the kidneys and testicles were examined. Histopathological examination of the kidneys of animals that were given water treated with a magnetic field with an induction of 500, 1000 and 1500 gauss revealed n
... Show MoreThe corrosion behavior of mild sleet in saturated aerated and de-aerated Ca(OH)2 solution was investigated using electrochemical measurements. The work was carried out with small coupons immersed in solutions containing different quantities of NaCl in presence of various NaN02 concentrations as corrosion inhibitors. It has been found thal:(1 ) In presence of NaCl, the time required to reach O2 evolution potential in de-aerated Ca(OH)2 polarized at 10μA/cm 2 is function of inhibitor concentration and it becomes lass as NaN02 increases compared with zero presence indicating the effectiveness of N
... Show MoreThe effluent quality improvement being discharged from wastewater treatment plants is essential to maintain an environment and healthy water resources. This study was carried out to evaluate the possibility of intermittent slow sand filtration as a promising tertiary treatment method for the sequencing batch reactor (SBR) effluent. Laboratory scale slow sand filter (SSF) of 1.5 UC and 0.1 m/h filtration rate, was used to study the process performance. It was found that SSF IS very efficient in oxidizing organic matter with COD removal efficiency up to 95%, also it is capable of removing considerable amounts of phosphate with 76% and turbidity with 87% removal efficiencies. Slow sand filter efficiently reduced the mass of suspended
... Show MoreA field-pilot scale slow sand filter (SSF) was constructed at Al-Rustamiya Sewage Treatment Plant (STP) in Baghdad city to investigate the removal efficiency in terms of Biochemical Oxygen Demand (BOD5), Chemical oxygen demand (COD), Total Suspended Solids (TSS) and Chloride concentrations for achieving better secondary effluent quality from this treatment plant. The SSF was designed at a 0.2 m/h filtration rate with filter area 1 m2 and total filter depth of 2.3 m. A filter sand media 0.35 mm in size and 1 m depth was supported by 0.2 m layer of gravel of size 5 mm. The secondary effluent from Al-Rustamiya STP was used as the influent to the slow sand filter. The results showed that the removal of BOD5, COD, TSS, and Chloride were
... Show More