This paper introduces experimental results of eighteen simply supported reinforced concrete beams of cross sections ( ) and length 3000 mm to study the effect of lacing reinforcement on the performance of such beams under static and fatigue loads. Twelve reinforced concrete beams (two of them are casted with vertical shear reinforcement used as control beams) are tested under four points bending loading with displacement control technique and six laced reinforced concrete beams were exposed to high frequency (10 Hz) by fixing the fatigue load in each cycle. Three parameters are used in the designed beams, which are: lacing bar diameter (4mm, 6mm, and 8mm), lacing bar inclination angle to horizontal , and lacing steel rat
... Show MoreEducation specialists have differed about determining the best ways to detect the
talented. Since the appearance of the mental and psychological measurement movement, some
scholars adopted intelligence ratios as a criterion to identify the talented and others went to
rely on the degree of academic achievement. Each of these two methods has its own flaws and
mistakes and a large number of talented children were victims of these two methods.
Therefore the need to use other scales for the purpose of detection of talented children
appeared because they provide valuable information which may not be obtained easily
through objective tests and these scales are derived from consecutive studies of gifted andtalented children
The fuzzy assignment models (FAMs) have been explored by various literature to access classical values, which are more precise in our real-life accomplishment. The novelty of this paper contributed positively to a unique application of pentagonal fuzzy numbers for the evaluation of FAMs. The new method namely Pascal's triangle graded mean (PT-GM) has presented a new algorithm in accessing the critical path to solve the assignment problems (AP) based on the fuzzy objective function of minimising total cost. The results obtained have been compared to the existing methods such as, the centroid formula (CF) and centroid formula integration (CFI). It has been demonstrated that operational efficiency of this conducted method is exquisitely develo
... Show MoreGenerally fossil based fuels are used in internal combustion engines as an energy source.
Excessive use of fossil based fuels diminishes present reserves and increases the air pollution in
urban areas. This enhances the importance of the effective use of present reserves and/or to develop
new alternative fuels, which are environment friendly. Use of alternative fuel is a way of emission
control. The term “Alternative Gaseous Fuels” relates to a wide range of fuels that are in the
gaseous state at ambient conditions, whether when used on their own or as components of mixtures
with other fuels.
In this study, a single cylinder diesel engine was modified to use LPG in dual fuel mode to study
the performance, emis
This research aims to the possibility of evaluating the strategic performance of the State Board for Antiquities and Heritage (SBAH) using a balanced scorecard of four criteria (Financial, Customers, Internal Processes, and Learning and Growth). The main challenge was that the State Board use traditional evaluation in measuring employee performance, activities, and projects. Case study and field interviews methodology has been adopted in this research with a sample consisting of the Chairman of the State Board, 6 General Managers, and 7 Department Managers who are involved in evaluating the strategic performance and deciding the suitable answers on the checklists to analyze it ac
... Show MoreThis research aims to the possibility of evaluating the strategic performance of the State Board for Antiquities and Heritage (SBAH) using a balanced scorecard of four criteria (Financial, Customers, Internal Processes, and Learning and Growth). The main challenge was that the State Board use traditional evaluation in measuring employee performance, activities, and projects. Case study and field interviews methodology has been adopted in this research with a sample consisting of the Chairman of the State Board, 6 General Managers, and 7 Department Managers who are involved in evaluating the strategic performance and deciding the suitable answers on the checklists to analyze it according to the 7-points Likert scale. Data analysis re
... Show MoreContemporary management is interested in the process of performance assessment because of its significance in the field of planning and controlling the multiactiveties to attain its goals and uncovering digression of virtual performance after comparing it with the plan or equitable performance.
Digression is analyzed to enable management control centers of authority.
Assessment process significance is closely related by setting definite categories to evaluate the economic activity to know the ability to achieves aims.
This study concentrated on the most important categories that used to evaluate company understudy with ather categories suggested to complete assessment process.
This study is in
... Show MoreFor a long time, the intensification of profit represented a major goal for the company management ,but this goal confirmed a series of restrictions such the constriction on short period, the time rather than on long and medium strategic goal, the relationships with customers ,the supplies, employees , This goal is replaced by another one (intensification of the company's value) ,and the fortune of the share holders itself ,for the purpose of creating value, the company must generate great outcomes to cover the operating expense and to insure the a suitable compensation to the invested capital (the market value added) is the indication used to estimate the company ability to create value –added the development
... Show MoreThis paper studied the behaviour of reinforced reactive powder concrete (RPC) two-way slabs under static load. The experimental program included testing three simply supported slabs of 1000 mm length, 1000 mm width, and 70 mm thickness. Tested specimens were of identical properties except their steel fibers volume ratio (0.5 %, 1 %, and 1.5 %). Static test results revealed that, increasing steel fibers volume ratio from 0.5% to 1% and from 1% to 1.5%, led to an increase in: first crack load by (32.2 % and 52.3 %), ultimate load by (36.1 % and 17.0 %), ultimate deflection by (33.6 % and 3.4 %), absorbed energy by (128 % and 20.2 %), and the ultimate strain by (1.1 % and 6.73 %). The stiffness and ductility of the specimens also increased. A
... Show More