Preferred Language
Articles
/
BYbYsoYBIXToZYALkLIS
Developing Water Quality Index to Assess the Quality of the Drinling Water
...Show More Authors

In the present study, an attempt has been to develop a new water quality index (WQI) method that depends on the Iraqi specifications for drinking water (IQS 417, 2009) to assess the validity of the Euphrates River for drinking by classifying the quality of the river water at different stations along its entire reach inside the Iraqi lands. The proposed classifications by this method are: Excellent, Good, Acceptable, Poor, and Very poor. Eight water quality parameters have been selected to represent the quality of the river water these are: Ion Hydrogen Concentration (pH), Calcium (Ca), Magnesium (Mg), Sodium (Na), Chloride (Cl), Sulphate (SO_4), Nitrate (NO_3), and Total Dissolved Solids (TDS). The variation of the water quality parameters along the river have been represented by graphs using Excel.2013 software. The results revealed that the quality of the Euphrates River ranges from “Good” to “Poor”, it enters the Iraqi borders with “Good” water quality and gradually its quality begins to decrease after it receives pollution from many sources such as domestic sewage and different industrial effluents until its quality becomes “Poor” according to the proposed classification. Finally the proposed WQI can be used as a tool to assess the quality of the river with both place and time.

Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
The application of quality requirements in the Ministry of Labour and Social Affairs using the international standard (ISO 9001: 2015) Korean case study of the Iraqi Center
...Show More Authors

This research aims to study the mechanism of application of international specification requirements (ISO 9001: 2015) at the Iraqi Center- Korean Vocational Training return to vocational training department at the Ministry of Labour and Social Affairs for the purpose of preparing and creating the center to get a certificate of conformity with the requirements of the standard (ISO 9001: 2015) that would elevate the level of performance and services provided in the respondent Center after it is identified and the study of the reality of the quality management system by identifying strengths and weaknesses in the system to diagnose the gap and find ways to address that gap, and adopted the researchers the case study method to conduc

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Emulsified Kerosene from Water by Flotation
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Iraqi Journal Of Applied Physics
Fabrication of PAN:Cellulose Membrane for Oil/Water Separation
...Show More Authors

In this study, we fabricated nanofiltration membranes using the electrospinning technique, employing pure PAN and a mixed matrix of PAN/HPMC. The PAN nanofibrous membranes with a concentration of 13wt% were prepared and blended with different concentrations of HPMC in the solvent N, N-Dimethylformamide (DMF). We conducted a comprehensive analysis of these membranes' surface morphology, chemical composition, wettability, and porosity and compared the results. The findings indicated that the inclusion of HPMC in the PAN membranes led to a reduction in surface porosity and fiber size. The contact angle decreased, indicating increased surface hydrophilicity, which can enhance flux and reduce fouling tendencies. Subsequently, we evaluated the e

... Show More
Scopus
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Environmental Engineering And Science
Soybean peroxidase-catalysed removal of benzidines from water
...Show More Authors

Crude soybean peroxidase (SBP), isolated from soybean seed coats (hulls) at unusually low concentrations, catalyses the oxidative polymerisation of hazardous aqueous benzidine and its 3,3′-dichloro, 3,3′-dimethyl and 3,3′-dimethoxy derivatives in the presence of hydrogen peroxide. The optimum operating conditions for oxidation of 0·10 mM benzidine were investigated. At pH 5, the hydrogen peroxide-to-substrate concentration ratio was 1·5 and the minimum SBP concentration required to achieve at least 95% conversion of the benzidine in synthetic wastewater was 0·43 mU/ml. Progress curves were established for the conversion of the four substrates, and apparent first-order rate constants were derived. Enzyme-catalysed polym

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Crossref
Publication Date
Mon Jan 07 2019
Journal Name
Drinking Water Engineering And Science Discussions
De-chlorination of drinking water by forced aeration
...Show More Authors

Abstract. Shock chlorination is a well-known practice in swimming pools and domestic wells. One of the limitations for using this technique in drinking water purification facilities is the difficulty of quickly removing high chlorine concentrations in water distribution systems or production facilities. In order to use this method in the drinking water industry a shock de-chlorination method should be introduced for producing microorganism and biocide free water. De-chlorination using natural stagnant aeration (leaving the water to lose the chlorine naturally) is the safest known method if compared with chemical and charcoaling methods. Unfortunately, stagnant aeration is a slow process. Therefore, developing a process for accelerat

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Fri Jan 04 2019
Journal Name
Drinking Water Engineering And Science Discussions
Bio-purification of drinking water by froth flotation
...Show More Authors

Abstract. The main technique for removing bacteria from water for various applications is chemical disinfection. However, this method has many disadvantages such as producing disinfectant by-products (DBPs), biofilm formation and either rendering the water unpotable (at high residual disinfection) or leaving a potential for lethal diseases such as Cholera (if the residual disinfection is too low). Recently, a process was developed for continuous removal of bacteria from water using the principle of froth flotation through compressed air only without any chemicals (Hassan, 2015). This work examines the extent to which chemical free froth flotation can purify drinking water. The experiments were carried out using two flotation columns

... Show More
View Publication
Crossref
Publication Date
Sun Jul 12 2020
Journal Name
International Journal Of Research In Social Sciences And Humanities
RISK MANAGEMENT AND ITS REFLECTION ON THE QUALITY OF MUNICIPAL SERVICE, CASE STUDY IN SALAHALDDIN SEWERAGE DIRECTORATE
...Show More Authors

The current research aims to identify the risk management and its impact on the quality of service in the Salahalddin Sewerage Directorate, This is due to the great impact that the service provided by this institution plays in preserving health and the environment in the community, which has faced many administrative challenges, problems and issues as a result of the rapid and continuous environmental changes, and therefore, the adoption of administrative concepts such as risk management and knowledge of their impact on the quality of the municipal service is necessary to reach this service To the required levels. To achieve the research objectives, two main hypotheses have been formulated, the first of which is to find the extent of the li

... Show More
View Publication
Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
The Possibility of Applying Quality Management System ISO9001: 2008 in Station Project Al Rustumiya - A Case Study
...Show More Authors

The research study of the possibility of the application of the quality management system under the international standard ISO ISO9001: 2008 in the station project Rustumiya wastewater treatment of the Department of SEWER BAGHDAD - Baghdad MOREALITY as the first step in the right direction towards the implementation of total quality management (TQM), and the research Find the gap between the international standard and the quality system used in the organization surveyed through the use of checklists to analyze the gap, the checklist have included (191) items distributed on five basic requirements, according to the appearance in the international standard, namely, (quality management system, management responsibility, resource man

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The role of big data analytics in measuring and analyzing the quality costs of economic units : applied research in the Iraqi company for seed production
...Show More Authors

                The research aims to explain the role of huge data analyzes in measuring quality costs in the Iraqi company for the production of seed, and the research problem was diagnosed with the weakness of the approved method to measure quality costs, and the weak traditional systems of data analyzes, the researcher in the theoretical aspect relied on collecting sources and previous studies, as well as Adoption of the applied analytical approach in the practical aspect, as a set of financial analyzes were applied within the measurement of quality costs and a statement of the role of data analyzes in the practical side, the research concluded to a set of conc

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Determination of naturally occurring radionuclides in Disi aquifer water of Jordan
...Show More Authors

The Disi water samples were collected from different Disi aquifer wells in Jordan using a clean polyethylene container of 10-liter size. A hyper-pure germanium (HPGe) detector with high- resolution gamma-ray spectroscopy and a low background counting system was used for the identification of unknown gamma-rays emitting from radionuclides in the environmental samples. The ranges of specific activity concentrations of 226Ra and 228Ra in the Disi aquifer water were found to be from 0.302 ± 0.085 to 0.723 ± 0.207 and from 0.047 ± 0.010 to 0.525 ± 0.138 Bq L−1, with average values of 0.516 ± 0.090 and 0.287 ± 0.091 Bq L−1, respectively. The average combined radium (226Ra + 228Ra) activity and radium activity ratio (228Ra/226Ra) in Disi

... Show More
Scopus (2)
Scopus