In the present study, an attempt has been to develop a new water quality index (WQI) method that depends on the Iraqi specifications for drinking water (IQS 417, 2009) to assess the validity of the Euphrates River for drinking by classifying the quality of the river water at different stations along its entire reach inside the Iraqi lands. The proposed classifications by this method are: Excellent, Good, Acceptable, Poor, and Very poor. Eight water quality parameters have been selected to represent the quality of the river water these are: Ion Hydrogen Concentration (pH), Calcium (Ca), Magnesium (Mg), Sodium (Na), Chloride (Cl), Sulphate (SO_4), Nitrate (NO_3), and Total Dissolved Solids (TDS). The variation of the water quality parameters along the river have been represented by graphs using Excel.2013 software. The results revealed that the quality of the Euphrates River ranges from “Good” to “Poor”, it enters the Iraqi borders with “Good” water quality and gradually its quality begins to decrease after it receives pollution from many sources such as domestic sewage and different industrial effluents until its quality becomes “Poor” according to the proposed classification. Finally the proposed WQI can be used as a tool to assess the quality of the river with both place and time.
تم استخدام خرائط ضبط الجودة الإحصائية لتقييم جودة الخدمة التعليمية في جامعة الباحة، ويهدف هذا البحث إلى استخدام خرائط ضبط الجودة الإحصائية لقياس مستوى الجودة وفجوة الجودة بين توقعات الطلبة وإدراكاتهم لمستوى الخدمة الذي تقدمه جامعة الباحة. حيث تم اختيار عينة من 200 طالب وطالبة عشوائيا باستخدام العشوائية العنقودية من 4 كليات خلال الفترة 01 – 30/2015م، وجمعت البيانات من خلال استبيان جودة الخدمة الذي يقيس ت
... Show MoreFor cleaner air and unpolluted continue assessment study air pollution the city of
Baghdad by measuring the concentrations of air pollutants, which included TSP, Pb, where
the adoption of three stations (Andalus Square, Jadiriya, Allawi) are distributed in the city of
Baghdad in order to compare the concentrations of these pollutants with previous studies.
Study pointed out that the city's air contaminant, especially in minutes outstanding after
deducting the amount of atmospheric dust thick mechanism city this year where the highest
concentration of minutes outstanding (9895) micrograms / m 3 at the station Alawi and lower
concentration of 157 micrograms / m 3 at the station Alawi and this was higher than the
det
The present study aimed to use the magnetic field and nanotechnology in the field of water purification, which slots offering high efficiency to the possibility of removing biological contaminants such as viruses and bacteria rather than the use of chemical and physical transactions such as chlorine and bromine, and ultraviolet light and boiling and sedimentation and distillation, ozone and others that have a direct negative impact on human safety and the environment. Where they were investigating the presence in water samples under study Coli phages using Single agar layer method and then treated samples positive for phages to three types of magnetic field fixed as follows (North Pole - South Pole - Bipolar) and compare the re
... Show MoreThis study was concerned with using ozone gas in drinking water treatment plant at Ibn-Sina Company. The main purpose of this research is to find the best contactor for ozone unit proposed. An investigation was conducted to study the absorption of ozone by water in two type of absorber. The effects of the process variables (such as height of water column, contact time, and pH) on the amount of ozone absorbed were investigated. Box-Wilson central composite rotatable design is used to design the experimental work for the mentioned variables. It was found that the optimum value of the variables studied was:
i) Height of water column (90 cm)
ii) Contact time (17-18 min)
iii) PH (7 - 7.5)
In this research, radon concentrations in some types of healthy drinking water samples available in Iraq's market were measured using a technique called Durridge RAD-7-H2O with closed loop. Then the rate of annual effective dose in human taken this water is determined.
It was found that, radon concentrations in studied samples ranged between 1.2 Bq.m-3 to 142 Bq.m-3. The results of the radon concentrations and the rate of annual effective dose for drinking water samples were significantly lower than the USEPA and WHO recommended limits that equal 500 Bq/m3 and 1 mSv/y resp
... Show MoreThis study aimed to identify the role of digital transformation in improving the quality of the internal audit process. The researchers used the descriptive analytical approach, and the questionnaire was relied on as a study tool that was applied to the study population consisting of internal auditors working in banks listed on the Palestine Stock Exchange, and their number was (85). A checker and a comprehensive inventory method was used due to the small size of the community, where the response data of the questionnaire was analyzed and interpreted using the Statistical Packages Program (SPSS).
The results of the study showed that the use of digital transformation contributes to ensuring the quality of
... Show MoreThis research aims to identify the role of external environment factors on the quality of educational services, from the academic point of view, where the distribution of a questionnaire to a random sample of (100) university professors, and then analyzing a model, and test the validity of this model using structural modeling (SEM) (Structural Equation Modeling).
And then test the relationships between variables using the software of Statistical Package for Social Sciences (SPSS V.18), the research found a number of conclusions, the most important conclusion is: the external environment factors has significant impact on the quality of educational services.
Abstract
The entities responsible for regulating the financial market are seeking to provide high quality accounting information, to provide appropriate protection to investors, and thus encourage them and attract them to increase their investments. the research reached several conclusion, the most prominent of which comes :-
1-The production of high quality accounting information reduces investment costs and costs of processing accounting information.
2- The production of high quality accounting information helps investors identify the best investment opportunities.
3- The results of the statistical analysis showed that there is significant
... Show MoreFood fortification has an important and necessary role in compensating for the shortage of nutritional micronutrients, especially in developing and least developed countries. So, 12 samples of flour available in the local market, whether imported or locally produced flour, were obtained during 2019. The amount of base metal of the necessary iron element in the flour models studied which are available in local markets, measured by spot testing and was compared with the values that should be added according to the specification Iraqi standard. Results revealed the qualitative evaluation of iron in locally produced flour does not conform to the Iraqi standard and is almost free of any reinforcement. While the percentage of imp
... Show MoreThe variety of clean energy sources has risen, involving many resources, although their fundamental principles remain consistent in terms of energy generation and pollution reduction. The using of hydropower system for energy production also has a dynamic impact in which it utilizes to harness the water for the purpose of energy production. As it is important to overcome the problem of accidents in the highway and rural areas in the case of server rainfall and flood by implementation a smart system that used for energy production. This paper aims to develop a controlled hydropower system installed in the drainage sinks allocated in highway roads used for producing. The proposed system consists of storage unit represented by pipes used for t
... Show More