The aim of this research sought to assess the background radiati on levels of medicinal plant samples in Iraq.The D, AED, and ELCRThe D values are 0.164 ± 0.006 µSv/h.The radiation dose outputs from the afore mentioned research were juxtaposed with the safety threshold of 0.247 µSv/h set by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) in 2008 and the National Council on Radiation Pr otection and Measurements (NCRP) in 2009.The radiation exposure for all samples in this investigation is within the permissible limits.Additionally, t he AED values obtained from microsieverts per hour are (1.31 ±0.0326 mS v/y), indicating variability, with a maximum permissible limit of 2.4 mSv/y ear, as per the 2008 United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) and the 2009 National Council on Radiatio n Protection and Measurements (NCRP).The statistics demonstrate that all detected AED levels during sample testing were below safety thresholds.T he ELCR×103 values exhibited variability, with an average of (4.486 ±0.1 26).The background radiation levels in these facilities are deemed safe, and their use does not provide any substantial danger of radiation exposure.
Abstract: The article aimed to formulate an MLX binary ethosome hydrogel for topical delivery to escalate MLX solubility, facilitate dermal permeation, avoid systemic adverse events, and compare the permeation flux and efficacy with the classical type. MLX ethosomes were prepared using the hot method according to the Box–Behnken experimental design. The formulation was implemented according to 16 design formulas with four center points. Independent variables were (soya lecithin, ethanol, and propylene glycol concentrations) and dependent variables (vesicle size, dispersity index, encapsulation efficiency, and zeta potential). The design suggested the optimized formula (MLX−Ethos−OF) with the highest desirability to perform the
... Show MoreThree different types of nozzles (different wear rate) were used in this study. They are classified depending on the severity of their wear to three groups: new, worn and damaged nozzles. Those nozzles were spraying with the same application rate (303 l/ha) on two-year field trials; this was achieved by changing the spraying pressure for each group of nozzles in order to get the same application rate. This practice is usually done by operators of sprayers, who calibrate the sprayers on the same application rate every year without changing the nozzles, so they tend to reduce the spraying pressure in order to compensate the flow rate increase due to the nozzles yearly wear. Two types of
Coagulation is the most important process in drinking water treatment. Alum coagulant increases the aluminum residuals, which have been linked in many studies to Alzheimer's disease. Therefore, it is very important to use it with the very optimal dose. In this paper, four sets of experiments were done to determine the relationship between raw water characteristics: turbidity, pH, alkalinity, temperature, and optimum doses of alum [ .14 O] to form a mathematical equation that could replace the need for jar test experiments. The experiments were performed under different conditions and under different seasonal circumstances. The optimal dose in every set was determined, and used to build a gene expression model (GEP). The models were co
... Show MoreThe research aims to know the extent of the impact of the risks of foreign exchange centers represented in commitment risks, liquidity risks, and exchange rate risks on the continuity of the economic unit. The research in the light of its presentation of the intellectual, cognitive and applied contributions about the risks of foreign currency centers and the continuity of the economic unit, and represented the research community in the banking sector, and the sample included nine private commercial banks listed in the Iraq Stock Exchange, and they relied on the research on a time series consisting of four years that extended from one year 2017 to 2020. The research problem was the impact of the risks associated with foreign currency cent
... Show MoreA batch and flow injection (FI) spectrophotometric methods are described for the determination of barbituric acid in aqueous and urine samples. The method is based on the oxidative coupling reaction of barbituric acid with 4-aminoantipyrine and potassium iodate to form purple water soluble stable product at λ 510 nm. Good linearity for both methods was obtained ranging from 2 to 60 μg mL−1, 5–100 μg mL−1 for batch and FI techniques, respectively. The limit of detection (signal/noise = 3) of 0.45 μg mL−1 for batch method and 0.48 μg mL−1 for FI analysis was obtained. The proposed methods were applied successfully for the determination of barbituric acid in tap water, river water, and urine samples with good recoveries of 99.92
... Show MoreA simple, rapid, sensitive and inexpensive approach is described in this work based on a combination of solid‐phase extraction of 8‐hydroxyquinoline (8HQ), for speciation and preconcentration of Cr(III) and Cr(VI) in river water, and the direct determination of these species using a flow injection system with chemiluminescence detection (FI–CL) and a 4‐diethylamino phenyl hydrazine (DEAPH)–hydrogen peroxide system. At different pH, the two forms of chromium [Cr(III) and Cr(VI)] have different exchange capacities for 8HQ, therefore two columns were constructed; the pH of column 1 was adjusted to pH 3 for retaining Cr(III) and column 2 was adjusted to pH 1 for retaining of Cr(VI). The sorbe
The objective of this study is to evaluate the level of parathyroid hormone, Co enzyme Q and total antioxidant status in serum’s women with fibromyalgia syndrome firstly, then to demonstrate if these biochemical markers affected by age and obesity.
This study was performed at Rheumatology and Rehabilitation Consultation Unit in Baghdad Teaching Hospital. Venous blood sample were drawn from (59) female with FMS and (30) control (without FMS). The serum was obtained after on standing in order to coagulate then centrifuged. The mean age± SD of FMS group was (42.22±15.34) years and for control was (40.7±18.22) years. Those participants were subdivided into four different groups acc
... Show More