Background: Although methotrexate (MTX) is a frequently used chemotherapy drug, its effectiveness is sometimes hampered by the drug's toxic consequences. Omega 7 is a monounsaturated fatty acid, with different anti-inflammatory, anti-diabetic anti-obesity applications, and its possible protective effects against MTX-induced blood toxicity were investigated in this study. Objective: Evaluation of possible protective effects of omega7 against MTX-induced blood toxicity. Methods: 30 mice were divided into five groups, the First group take liquid paraffin orallyfor 7 days for served as negative control and the second group take methotrexate (20mg/kg) intraperitoneallyto serve as a positive control,the third group takes omega 7 (100mg/kg)orally for 7 days, forth groupreceived (50mg/kg ) omega 7orally for 7 days as well as give It methotrexate (20mg/kg) on day 8, the fifth groupreceived (100mg/kg ) omega 7orally for 7 days as well as give It methotrexate (20mg/kg) on day 8. After that, the animals were killed and took blood samples for measuring blood parameters, such as PCV, Hb, MCV, MCH, platelet, WBC count and Differential WBC. Results: the results showed the presence of a decrease in both the RBC from which MCV and MCH count showed a significant decrease at a dose of 20mg/kg concentration of methotrexate, omega7 at a dose of 50 and 100 mg/kg work to increase the variables above, Concerning the WBC was significantlydecreased in the totals and increased in monocytes count for the study when giving methotrexate while reversed when giving omega7 with this drug. Conclusion: omega7 has a significant protective role in Methotrexate-induce Blood Toxicity in Mice.
This article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while
... Show MoreProtection of the oil pipelineswhich extracted from the wells was found to shut the well and prevent the leakage of oil when broken using safety valve. This valve is automatically activated by loss of pressure between the well and pipelines, which take the pressure, signal from hydraulic pressure sensor through pressure control valve which has constant or variable value but it is regulated manually. The manual regulatory process requires the presence of monitoring workers continuously near the wells which are always found in remote areas. In this paper, a smart system has been proposed that work with proportional pressure control valve and also electronic pressure sensor through Arduino controller, which is programmed in a way that satisfie
... Show MoreImproving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application
Fiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and
This research analyzes the level of the short circuit effect of the Iraqi super network and decides the suitable location for the High Voltage Direct Current (HVDC) connections in order to obtain the best short circuit reduction of the total currents of the buses in the network. The proposed method depends on choosing the transmission lines for Alternating current (AC) system that suffers from high Short Circuit Levels (SCLs) in order to reduce its impact on the transmission system and on the lines adjacent to it and this after replacing the alternating current (AC) line by direct current (DC) line. In this paper, Power System Simulator for Engineering (PSS/E) is used to model two types of HVDC lines in an effective regi
... Show More