In the rapidly evolving telecommunications industry, accurate valuation of tangible assets remains a critical challenge that requires adherence to universally recognized standards. This study addresses the pressing need for transparent and precise asset valuation methodologies that are pivotal for informed investment decisions and financial reporting. It aims to bridge the theoretical and practical divide in asset valuation by applying International Valuation Standards (IVS) 300 and 400 to Asiacell Communications PJSC, a leading entity in the sector. Focusing on five key tangible assets from 2018 to 2022 – lands, buildings, plant and equipment, means of transport and transfer, and furniture and office equipment – the study employs the income approach, augmented by a random walk model for future cash flow forecasting and the weighted average cost of capital for discounting. This innovative methodology offers a comprehensive valuation framework, revealing that despite Asiacell’s consistent growth rate of 4.63%, all asset categories experienced a depreciation upon revaluation. The study’s findings underscore the significance of implementing IVS in elucidating the asset valuation process, demonstrating the potential discrepancies between book values and standards-based valuations. The application of IVS 300 and IVS 400 not only enhances the transparency and accuracy of asset valuation but also provides valuable insights into the contributions of tangible assets to future income within the prevailing market conditions. By offering a replicable model for asset valuation in dynamic industries, this study contributes to the broader discourse on financial reporting and investment analysis, setting a foundation for future exploration in the field.
Background: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant
... Show MoreSevere periodontitis is ranked as the sixth most prevalent disease affecting humankind, with an estimated 740 million people affected worldwide. The diagnosis of periodontal diseases mainly relies upon assessment of conventional clinical parameters. However, these parameters reflect past, rather than current, clinical status or future disease progression and, likely, outcome of periodontal treatment. Specific and sensitive biomarkers for periodontal diseases have been examined widely to address these issues and some biomarkers have been translated as point-of-care (PoC) tests. The aim of this review was to provide an update on PoC tests for use in the diagnosis and management of periodontal diseases. Among the PoC tests developed so
... Show MoreAround 65 million individuals suffer from epilepsy worldwide, and when it is not properly treated, it is linked to higher rates of physical harm and mortality. Due to the requirement for long‐term therapy and the side effects of many medications, medication compliance is a significant issue. The purpose of this review was to summarize the findings of previous studies examining the quality of life (QOL), adherence, patient education, and medication knowledge, as well as the impact of a pharmacist‐led educational intervention. Additionally, to find out if these studies benefit epileptic patients, to find the appropriate method used to help them in all aspects of their lives, and to use these in future studies. A systematic and comprehensi
... Show MorePurpose: This study aimed to compare the stability and marginal bone loss of implants inserted with flapped and flapless approaches 8 weeks after surgery and 3 months after loading. Material and Methods: Thirty SLActive implants were inserted in 11 patients and early loaded with final restoration 8 weeks after healing period. The stability values determined by Osstell and the marginal bone loss measured by CBCT at the initial time (1st) and 8 weeks of the healing period (2nd) and 3 months after loading (3rd). Results: The overall survival rate was 100%. A significant increase in the 3rd implant stability value in the age of ˂ 40. A significant decrease in the 2nd implant stability value in both gender and traumatic zone with a flapless app
... Show MoreThe impact of a Schiff base namely 2-((thiophen-2-ylmethylene)amino)benzenethiol to corrode mild steel in 1 M HCl resolved was evaluated using different weight loss technique and scanning electron microscopy (SEM).different weight measurements to expand that the 2-((thiophen-2-ylmethylene) amino) benzenethiol inhibits the corrosion of mild steel through adsorbing of top for mild steel and block the active locality. The inhibitive impacts of 2-((thiophen-2-ylmethylene)amino)benzenethiol increase with increasing concentration and decrease with increasing temperature. SEM to checking revealed that the alloy surface was quite unaffected and formed protective film on its surface. The investigated
... Show MoreThe addition of new reactive sites on the surface area of the inert sand, which are represented by layered double hydroxide nanoparticles, is the primary goal of this work, which aims to transform the sand into a reactive material. Cetyltrimethylammonium bromide (CTAB) surfactant is used in the reaction of calcium extracted from solid waste-chicken eggshells with aluminum prepared from the cheapest coagulant-alum. By separating amoxicillin from wastewater, the performance of coated sand named as "sand coated with (Ca/Al-CTAB)-LDH" was evaluated. Measurements demonstrated that pH of 12 from 8, 9, 10, 11, and 12, CTAB dosage of 0.05 g from 0, 0.03, 0.05, and 0.1 g, ratio of Ca/Al of 2 from 1, 2, 3, and 4, and mass of sand of 1 g/50 mL from
... Show MoreThis research aims at identifying the system of applying the QRcode system for acquisition of chemistry by first class female students studying at intermediate schools knowledge and its effect on creative thinking. The research sample consisted of (63) female students in one of the intermediate schools in Baghdad/Iraq using two equivalents experimental and control groups. The scientific context used was based on the chemistry text book related to the periodic table, (Metals) for the first group of students and Alkaline metals,Nonmetals, Metalloides) for the second group. The research methodology employed consisted of the followings :Measuring students acquisition using (35) issues. The results were verified for their face validity and obtai
... Show MoreThe business process re-engineering is one of the popular concepts at this time because its provide a radical solution for the problems that companies faces. This method appeared because the changes of competition and costumers 'desires at the two last decades. The markets become wider because of the globalization so the companies must change its way to stay a life.
The research aim is to concentrate on the BPR because it's a philosophy aims to re-organize the company's business process to achieve the competitive advantage, the research also aims to a plicate the BPR using cost management technique in the State Company of Vegetable Oils Industry.
&nb
... Show MoreABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of
... Show More