Preferred Language
Articles
/
BRcwVo4BVTCNdQwCZENp
Determination of the suitability period of S-3 diesel oil when used in tractor engines
...Show More Authors

The diesel oil type S-3 specified for diesel engine has limited the suitability for diesel trucks for 8000 km, but didn't clarify its suitability if used in tractor engines.It is known that the work style of farm tractor differs from that of other vehicles where tractors are used for all the activities in sever conditions and under the complete usage of the available power and capability, so there is no sign or indication of the usage period of this oil in tractor's engine. The oil has been used on Cirta C6806 tractors. The manual book of the tractor's engine, Deutz recommends changing the oil every 100 hrs. Therefore the main goal of this research is to give the recommended working hours for S-3 diesel oil when used in farm tractor engines. Five tractors have been used in this research and the engine oil was changed for the interval period of 20 hrs starting from 20, then 40, 60, 80, 100 and 120 hours. At the end of each period the oil of the five tractors was mixed and a sample was taken for testing. This procedure was repeated three times in order to obtain accurate results with statistical analysis. The statistical analysis results showed that the S-3 diesel oil deteriorates after 40 working hours because of the great consumption of the oil after this period and therefore this research recommends that the usage period of S-3 oil should not exceed more than 40 working hours when it is used in tractor's engine.

Scopus
View Publication
Publication Date
Thu Mar 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Chromium Using Promethazine Hydrochloride - Application in Various Sample
...Show More Authors

       A rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium (VI) was studied. The method is based on the reaction of chromium (VI) with promethazine forming a red colored species by chromium in hydrochloric acid  medium  and exhibits  a maximum absorbance at 518 nm. A plot of absorbance with chromium (VI) gives a straight line indicating that  Beer’s law has been obeyed over the range concentration of 0.05-4.0 µg/ml with a molar absorptivity of chromium(VI) 2.04 ï‚´ 104       l.mol-1.cm-1 , Sandell’s sensitivity index of 0.0025 µg.cm-2  while the limit of detection (LOD) was found to be 0.0924 µg.ml

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 30 2021
Journal Name
Baghdad Science Journal
Spectrophotometric and Spectrofluorimetric Determination of Terazosin in Tablets by Eosin Y
...Show More Authors

Simple, sensitive and accurate two methods were described for the determination of terazosin. The spectrophotometric method (A) is based on measuring the spectral absorption of the ion-pair complex formed between terazosin with eosin Y in the acetate buffer medium pH 3 at 545 nm. Method (B) is based on the quantitative quenching effect of terazosin on the native fluorescence of Eosin Y at the pH 3. The quenching of the fluorescence of Eosin Y was measured at 556 nm after excitation at 345 nm. The two methods obeyed Beer’s law over the concentration ranges of 0.1-8 and 0.05-7 µg/mL for method A and B respectively. Both methods succeeded in the determination of terazosin in its tablets

View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Jan 18 2019
Journal Name
Asian Journal Of Chemistry
Determination of Chemicals and its Isotopic Composition in Tigris River,Iraq
...Show More Authors

Stable isotope (?18O, ?D) values were determined along with the chemical compositions at 10 different locations along the Tigris river between Baghdad-Ammara cities of Iraq. The physico-chemical parameters and isotopic data were measured. The sampling site represents 34 % of total Tigris river in the republic of Iraq. The systematically increased in values of stable isotope as move from the downstream of the river and the most significantly appears at Kut lake. This increase occurs as a result of several factors, viz. (a) evaporation occurs low water level in the river and its tributaries, and (b) return flow water to the river from irrigation water in groundwater systems. The change in ion distribution and in the isotopic values related di

... Show More
Publication Date
Tue Mar 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Amoxicillin Trihydrate in Pure and Pharmaceutical Dosage Forms
...Show More Authors

A rapid and sensitive method for the determination of amoxicillin trihydrate (AMXT) based on the diazo-coupling reaction was studied. Sulphanilic acid diazotizes with nitrite ion in acidic medium to produce a water soluble, colorless diazonium ion, which subsequently coupled with AMXT to form a colored azo dye in the alkaline medium, having maximum absorption at 455 nm. The calibration graph showed that Beer's law is obeyed over the concentration range of 0.3 – 30.0 μg/mL of AMXT, with the detection limit of 0.15 μg/mL and molar absorptivity was 2.3 × 104 L/mol.cm. The accuracy and the precision were acceptable depending upon the values of error percentage and relative standard deviation. The influence of common interfer

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Chromium Using Indigo Carmine -Application in Various Samples
...Show More Authors

A rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Carbofuran with Diazotized Benzidine in Environmental Water Samples
...Show More Authors

A simple, rapid, accurate and sensitive spectrophotometric method has been developed for the determing carbamate pesticides in both pure and water samples. The method is appropriate for the determination of carbofuran in the presence of other ingredients that are usually available in dosage forms. The effect of organic solvents on the spectrophotometric properties of the azo dye and the structure of the resulting product have also been worked out and it is found to be 1:1 benzidine :carbofuran. The method can be successfully applied to determination of carbofuran in water samples. The method is based on diazotization of Benzidine (4, 4 – diamino biphenyl) with sodium nitrite and hydrochloric acid followed by coupling with carbofuran

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 20 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of Some Polychlorinated Biphenyls in River Tigris within Baghdad City
...Show More Authors

A number of aqueous samples were collected from river Tigris in Baghdad city, enriched ~1000 times using solid phase extraction (SPE), then extracted the trace concentrations of some polychlorinated biphenyls (PCB) using an aqueous two-phase system (ATPS) composed of 1Methylpyridinium chloride [MePy]Cl and KH2PO4 salt. High performance liquid chromatography technique coupled with ultraviolet (HPLC-UV) is used for the quantification. Extraction under the optimized conditions of pH, solvent composition, duration and temperature has given with a yield of PCB about 91%. The limit of detection (LOD) and limit of quantification (LOQ) for analyses are 0.11-0.62 µg.L−1 and 2.67–3.43 µg.L−1 respectively with relative stan

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Salbutamol Sulphate and Isoxsuprine Hydrochloride in Pharmaceutical Formulations
...Show More Authors

A simple, sensitive and accurate spectrophotometric method has been developed for the determination of salbutamol sulphate (SAB) and isoxsuprine hydrochloride (ISX) in pure and pharmaceutical dosage. The method involved oxidation of (SAB) and (ISX) with a known excess of N-bromosuccinamid in acidic medium, and subsequent occupation of unreacted oxidant in decolorization of Evans blue dye (EB). This, in the presence of SAB or ISX was rectilinear over the ranges 1.0-12.0, 1.0-11.0 µg/mL, with molar absorptivity 4.21×104 and 2.58×104 l.mol-1.cm-1 respectively. The developed method had been successfully applied for the determination of the studied drugs in their pharmaceutical dosage resulting i

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Wed Mar 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Testing of a Potentially Used Antiseptic Consists of Povidon Iodine, Hydrogen Peroxide and Aloe Vera
...Show More Authors

In this study a new antiseptic was formulated and tested to match the effectiveness against microorganisms. The formulation consisted of Povidone - Iodine (PVP-I) (10%), H2O2 (3%) and Aloe Vera gel (pure). Different ratios of these materials were prepared within the acceptable range of pH for an antiseptic (3-6). The prepared samples were tested. The In Vitro test was performed by using four bacteria, two were Gram-Positive (Staphylococcus aureus and Bacillus cereus) and two were Gram-Negative (Escherichia coli and Pseudomonas aeruginosa). The new antiseptic showed 100% killing rate for E. coli, Ps. aeruginosa and S. aureus and 96.4667% killing rate for B. cereus. When the new antiseptic was compared with two common

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Jun 03 2017
Journal Name
International Journal Of Science And Research
The Sealing Ability of New Bioceramic Material Used to Repair Furcal Perforation Compared with the Traditional Repair Materials: UV Spectrophotometer Analysis
...Show More Authors

Abstract: Iatrogenic furcal root perforations are serious complications during dental treatment. This study was aimed to compare the sealing ability of new bioceramic root repair material TotalFill® with the other perforation repair materials (GIC, MTA and Biodentine) using a dye- extraction method.Materials and Methods: Forty extracted, human mandibular molars with non-fused well developed root were collected. Artificial perforations were made from the external surface of the teeth. Then the teeth were randomly divided into 4 experimental groups (n= 10) according to the type of repair material used in this study; Medifil glass ionomercement, TotalFill® bioceramic root repair material, BiodentineTM and MTA Plus. The specimens were then im

... Show More
Preview PDF