Preferred Language
Articles
/
BRcwVo4BVTCNdQwCZENp
Determination of the suitability period of S-3 diesel oil when used in tractor engines
...Show More Authors

The diesel oil type S-3 specified for diesel engine has limited the suitability for diesel trucks for 8000 km, but didn't clarify its suitability if used in tractor engines.It is known that the work style of farm tractor differs from that of other vehicles where tractors are used for all the activities in sever conditions and under the complete usage of the available power and capability, so there is no sign or indication of the usage period of this oil in tractor's engine. The oil has been used on Cirta C6806 tractors. The manual book of the tractor's engine, Deutz recommends changing the oil every 100 hrs. Therefore the main goal of this research is to give the recommended working hours for S-3 diesel oil when used in farm tractor engines. Five tractors have been used in this research and the engine oil was changed for the interval period of 20 hrs starting from 20, then 40, 60, 80, 100 and 120 hours. At the end of each period the oil of the five tractors was mixed and a sample was taken for testing. This procedure was repeated three times in order to obtain accurate results with statistical analysis. The statistical analysis results showed that the S-3 diesel oil deteriorates after 40 working hours because of the great consumption of the oil after this period and therefore this research recommends that the usage period of S-3 oil should not exceed more than 40 working hours when it is used in tractor's engine.

Scopus
View Publication
Publication Date
Sun Jan 01 2017
Journal Name
Al-mustansiriyah Journal Of Science
Development of Dispersive Liquid-Liquid Microextraction method combined with UV spectrophotometry for the Determination of Malathion Pesticide
...Show More Authors

A simple and novel method was developed by combination of dispersive liquid-liquid microextraction with UV spectrophotometry for the preconcentartion and determination of trace amount of malathion. The presented method is based on using a small volume of ethylenechloride as the extraction solvent was dissolved in ethanol as the dispersive solvent, then the binary solution was rapidly injected by a syringe into the water sample containing malathion. The important parameters, such the type and volume of extraction solvent and disperser solvent, the effect of extraction time and rate, the effect of salt addition and reaction conditions were studied. At the optimum conditions, the calibration graph was linear in the range of 2-100 ng mL-1 of ma

... Show More
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
The universal banking reality of the Industrial Bank through the causal relationship between the deposits of the Industrial Bank and the total loans granted - during the period (2004-2015)
...Show More Authors

Deposits with the Industrial Bank, together with loans received from others, are non-financial financial resources, which are sources of supply to the Industrial Bank of funds that allow the Bank to expand the granting of loans. The increases in this resource indicates that the bank is practicing comprehensive banking, which is consistent with the nature of the transformation of the banking system towards multiple businesses. Therefore, the research comes to highlight the causality of the trend between total deposits and total loans. And if the causality is found, is it one-way or two-way? How long is the impact?

View Publication Preview PDF
Crossref
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
The Determination of Critical-Sampling Scheme of Preprocessing for Multiwavelets Decomposition as 1st and 2nd Orders of Approximations.
...Show More Authors

One of the important differences between multiwavelets and scalar wavelets is that each channel in the filter bank has a vector-valued input and a vector-valued output. A scalar-valued input signal must somehow be converted into a suitable vector-valued signal. This conversion is called preprocessing. Preprocessing is a mapping process which is done by a prefilter. A postfilter just does the opposite.

The most obvious way to get two input rows from a given signal is to repeat the signal. Two rows go into the multifilter bank. This procedure is called “Repeated Row” which introduces oversampling of the data by a factor of 2.

 For data compression, where one is trying to find compact transform representations for a

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
β- catenin Expression and Its Relation to Bryne’s Invasive Grading System in Oral Squamous Cell Carcinoma
...Show More Authors

Background: Invasion in oral cancer involves alterations in cell-cell and cell-matrix interactions that accompanied by loss of cell adhesion. Catenins stabilize cellular adherence junctions by binding to E-cadherin, which further mediates cell-cell adhesion and regulates proliferation and differentiation of epithelial cells. The Wnt/β-catenin pathway is one of the major signaling pathways in cell proliferation, oncogenesis, and epithelial-mesenchymal transition. Aims of the study: to detect immunohistochemical distribution pattern and different subcellular localization of β-catenin in oral squamous cell carcinoma and relate such expression to Bryne’s invasive grading system. Materials and Methods: This study included 30 paraffi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jun 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Bone density determination for the maxilla and the mandible in different age groups by using computerized tomography (Part I)
...Show More Authors

Background: Mini implant stability is primarily related to local bone density; no studies have evaluated bone density related to mini implant placement for orthodontic anchorage between different age groups in the maxilla and the mandible. The present research aims to evaluate side, gender, age, and regional differences in bone density of the alveolar bone at various orthodontic implant sites. Materials and method: Fifty three individuals who were divided into two groups according to their age into: group I (ages 16-20 years) and group II (ages 21-29 years) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 102 points (51 in the maxilla

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Nitrofurantoin Drug in its Pharmaceutical Formulations Using MBTH as a Coupling Reagent
...Show More Authors

A direct, sensitive and efficient spectrophotometric method for the determination of nitrofurantoin
drug (NIT) in pure as well as in dosage form (capsules) was described. The suggested method was
based on reduction NIT drug using Zn/HCl and then coupling with 3-methyl-2-benzothiazolinone
hydrazone hydrochloride (MBTH) in the presence of ammonium ceric sulfate. Spectrophotometric
measurement was established by recording the absorbance of the green colored product at 610 nm.
Using the optimized reaction conditions, beer’s law was obeyed in the range of 0.5-30 μg/mL, with
good correlation coefficient of 0.9998 and limits of detection and quantitation of 0.163 and 0.544
μg/mL, respectively. The accuracy and

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations
...Show More Authors

The present study describes employing zero-, 1st - and 2nd -order derivative spectrophotometric methods have been developed for determination of lorazepam (LORA) and clonazepam (CLON) in commercially available tablets. LORA was determined by means of 1st (D1), 2nd (D2) derivative spectrophotometric techniques using zero cross, peak height, and Peak area. D1 used for the determination of CLON by using zero cross and peak height while D2 (zero cross) was used for the determination of CLON. The method was established to be linear in concentration containing different ratios of LORA and CLON range of (20-200 mg/L) and (5-35 mg/L) at wavelength range (250 -370 nm), (210-370nm) respectively. The proposed techniques are highly sensitive, precise a

... Show More
Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bismuth(III) with Arsenazo(III) Reagent in Water samples and Veterinary Preparation
...Show More Authors

A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Methods And Objects Of Chemical Analysis
Derivative Spectrophotometric Determination For Simultaneous Estimation Of Isoniazid And Ciprofloxacin In Mixture And Pharmaceutical Formulation
...Show More Authors

A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 μg∙mL-1 for Ciprofloxacin and 2 to 22 μg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) wer

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Mar 16 2021
Journal Name
International Journal For Computational Methods In Engineering Science And Mechanics
Determination of time-dependent coefficients in moving boundary problems under nonlocal and heat moment observations
...Show More Authors

View Publication
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref