Objective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time exposure, and radiologic reduction of the fracture using Chang criteria. Results: The setup, fluoroscopic exposure, and surgical times were shorter in the lateral decubitus group with statistical significance. The collodiaphyseal angles, the tip-to-apex distance, and the radiological fracture reduction were not significantly different between two groups. Conclusions: The lateral decubitus positioning is superior to the supine position in setup, fluoroscopic exposure, and surgical times
Aim: The purpose of this study was to analyze the patterns of facial fractures in children and to compare them between preschool- and school-aged children. Materials and methods: This retrospective observational study included 57 children with facial fractures. The variables analyzed were the age of the patients—divided into a preschool-aged group (0–5 years) and a school-aged group (6–12 years)—gender, cause of trauma, the facial bones involved, the pattern of fracture, the modality of treatment used, the time between injury and treatment, and the postoperative complications. Results: The incidence of facial fractures in children ≤12 years was 30.2%. The patients consisted of 40 (70.2%) males and 17 (29.8%) females, and most pati
... Show MoreObjective: To evaluate the knowledge and practices of nursing staff at the orthopedic wards relative to
nursing care presented to patients with femur fractures.
MethodologyThe sample consisted of (50) staff nurses was selected out of orthopedic wards of five
teaching hospital in Baghdad city for duration 15th Nivember 2001-15th of January 2002.
For the purpose of data collection, two instruments were constructed. First, observational
checklist for the practices measurements and second, knowledge test for the evaluation of the nurse
knowledge. Such construction was employed through literature review and validity expert’s responses.
Data were analyzed through the application of descriptive data analysis (frequency, p
L1 adaptive controller has proven to provide fast adaptation with guaranteed transients in a large variety of systems. It is commonly used for controlling systems with uncertain time-varying unknown parameters. The effectiveness of L1 adaptive controller for position control of single axis has been examined and compared with Model Reference Adaptive Controller (MRAC). The Linear servo motor is one of the main constituting elements of the x-y table which is mostly used in automation application. It is characterized by time-varying friction and disturbance.
The tracking and steady state performances of both controllers have been assessed fo
... Show MoreAbstract
The research addresses the specification table and the extent of its use in developing achievement tests, as well as detects the obstacles to its use through a sample of (120) respondents from the faculty members in some Baghdad schools and colleges. After unpacking and processing the data statistically, the research reached several results: the study sample do not use the test map in the development of their tests, as their percentage reached (82%) and there are no statistically significant differences in the use of the specification table by the sample members according to their place of work or the number of years of experience. The results also revealed the most important reasons that prevent the use
... Show MoreABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear imp
... Show MoreBACKGROUND: The rapidly growing knowledge regarding factors controlling tumour growth, with the new modalities of therapy acting on the biological activity of the tumours draw the attention of most cancer researches nowadays and represent a major focus for clinical oncology practice. For the detection of HER2/neu protein overexpression and gene amplification, immunohistochemistry (IHC) and in-situ hybridisation (ISH) is the recommended techniques, respectively, with high concordance between the two techniques. The current United Kingdom recommendations for HER2/neu testing are either for a two-tier system using IHC with reflex ISH testing in equivocal positive cases, or a one-tier ISH strategy. AIM: To compare the results of HER2/neu gene s
... Show MoreObjectives: To compare early pregnancy outcomes, including miscarriage, ectopic pregnancy, multiple pregnancy, and congenital anomalies, among women who conceived following ovulation induction with letrozole or clomiphene citrate. Methods: A prospective comparative observational study was conducted at Al-Elwiya Maternity Teaching Hospital and a private clinic in Baghdad, Iraq, from March 2023 to December 2024. One hundred infertile women aged 21–35 years who conceived after ovulation induction with either letrozole (5 mg/day) or clomiphene citrate (100 mg/day) for five days (cycle days 3–7) were enrolled. Participants were followed through early pregnancy with serial sonography at 6, 8–11, and 18–20 weeks of gestation. Data
... Show MoreRisks are confronting the foundations of buildings and structures when exposed to earthquakes which leads to high displacements that may cause the failure of the structures. This research elaborates numerically the effect of the earthquake on the vertical and lateral displacement of footing resting on the soil. The thickness of the footing and depth of soil layer below the footing was taken as (0.5, 1.0, and 2.0 m) and (10, 20 and 40m), respectively. The stiffness ratio of soil to footing was also elaborated at 0.68, 0.8, 1.0, and 1.7. The results showed an increase in the verticle displacement of footing as the duration of the earthquake increases. The increase of soil layer thickness below the footing leads to a reduction in the vertical
... Show More