This article investigates how an appropriate chaotic map (Logistic, Tent, Henon, Sine...) should be selected taking into consideration its advantages and disadvantages in regard to a picture encipherment. Does the selection of an appropriate map depend on the image properties? The proposed system shows relevant properties of the image influence in the evaluation process of the selected chaotic map. The first chapter discusses the main principles of chaos theory, its applicability to image encryption including various sorts of chaotic maps and their math. Also this research explores the factors that determine security and efficiency of such a map. Hence the approach presents practical standpoint to the extent that certain chaos maps will become relevant toward implementing image encryption system. This helps them select the best chaotic map for image encryption to ensure secure digital data. © 2024 Little Lion Scientific. All rights reserved.
Checkpoint inhibitors are a type of immune therapy used to treat different types of cancers. These drugs block different checkpoint proteins, for example, CTLA-4, PD-1, and PD-L1 inhibitors.
They block proteins that stop the immune system from attacking the cancer cells. Checkpoints are also described as a type of monoclonal antibody that antagonizes binding between B7 to CTLA-4 and PD-L1 to PD-1.
Immune checkpoint inhibitors are used to treat BARCA mutated triple-negative breast cancer (TNBCS) in patients who do not respond to chemotherapy, and also in the treatment of highly mutated and solid tumors such as brain tumors, liver, and pancreatic cancers.
Immune checkpoint inhibitors exhibit an effect on solid tumo
... Show MoreThe research aims to develop a proposed mechanism for financial reporting on sustainable investment that takes the specificity of these investments.
To achieve this goal, the researcher used (what if scenario) where the future financial statements were prepared for the year 2026, after completion of the sustainable project and operation, as the project requires four years to be completed.
The researcher relied on the results of the researchers collected from various modern sources relevant to the research topic and published on the internet, and the financial data and information obtained to assess the reality of the company's activity and its environmental, social, and economic i
... Show MoreA mathematical model constructed to study the combined effects of the concentration and the thermodiffusion on the nanoparticles of a Jeffrey fluid with a magnetic field effect the process of containing waves in a three-dimensional rectangular porous medium canal. Using the HPM to solve the nonlinear and coupled partial differential equations. Numerical results were obtained for temperature distribution, nanoparticles concentration, velocity, pressure rise, pressure gradient, friction force and stream function. Through the graphs, it was found that the velocity of fluid rises with the increase of a mean rate of volume flow and a magnetic parameter, while the velocity goes down with the increasing a Darcy number and lateral walls. Also, t
... Show MoreThe current study introduces a novel technique to handle electrochemical localized corrosion in certain limited regions rather than applying comprehensive cathodic protection (CP) treatment. An impressed current cathodic protection cell (ICCPC) was fabricated and firmly installed on the middle of a steel structure surface to deter localized corrosion in fixed or mobile steel structures. The designed ICCPC comprises three essential parts: an anode, a cathode, and an artificial electrolyte. The latter was developed to mimic the function of the natural electrolyte in CP. A proportional-integrated-derivative (PID) controller was designed to stabilize this potential below the ICCPC at a cathodic potential of −850 mV, which is crucial for prote
... Show MoreAbstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).
In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular
... Show MoreA reliable and environmental analytical method was developed for the direct determination of tetracycline using flow injection analysis (FIA) and batch procedures with spectrophotometric detection. The developed method is based on the reaction between a chromogenic reagent (vanadium (III) solution) and tetracycline at room temperature and in a neutral medium, resulting in the formation of an intense brown product that shows maximum absorption at 395 nm. The analytical conditions were improved by the application of experimental design. The proposed method was successfully used to analyze samples of commercial medications and verified throughout the concentration ranges of 25–250 and 3–25 µg/mL for both FIA and batch procedures, respecti
... Show MoreDBNRAHA Hameed, IJRSSH PUBLICATION, 2018