Background: EOS (encoded by the IKZF4 gene) is a member of the zinc finger transcription factor IKaros family, and plays a critical role in Treg suppressor functions, and maintaining Treg stability. IL-6 is a soluble mediator with a pleiotropic effect on inflammation, immune response, and hematopoiesis. Aim: To estimate serum IL-6 level and EOS gene expression in Iraqi patients with psoriasis. Method: Twenty-two patients with psoriasis (8 females, 14 males) with age ranged 18-72 years, were recruited from Baghdad Teaching Hospital, Dermatology Clinic, Baghdad, and 24 healthy donors. The serum levels of IL-6 by ELISA and the gene expression of IKZF4 (EOS gene) by RT-qPCR technique. Results: The results showed a non-significant difference in the level of IL-6 in those treated with topical therapy and others treated with Etanercept compared to control. A non-significant increase in patients treated with topical therapy was reported compared to patients treated with Etanercept. There was a higher significant percentage of IKZF4 gene expression folding in psoriasis patients treated with Etanercept compared to control group, while no significant differences reported between patients treated with topical therapy, Etanercept, and the control group. Conclusion: Activation of Regulatory T cells (Tregs) with Etanercept enhances EOS expression and decreases IL-6 production more than topical treatment in patients with psoriasis.
In this paper, effective slab width for the composite beams is investigated with special emphasis on the effect of web openings. A three dimensional finite element analysis, by using finite element code ANSYS, is employed to investigate shear lag phenomenon and the resulting effective slab width adopted in the classical T-beam approach. According to case studies and comparison with limitations and rules stipulated by different standards and codes of practice it is found that web openings presence and panel proportion are the most critical factors affecting effective slab width, whereas concrete slab thickness and steel beam depth are less significant. The presence of web opening reduces effective slab width by about 21%.
... Show MoreObjective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time expo
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreAbstract
The study of oxygen mass transfer was conducted in a laboratory scale 5 liter stirred bioreactor equipped with one Rushton turbine impeller. The effects of superficial gas velocity, impeller speed, power input and liquid viscosity on the oxygen mass transfer were considered. Air/ water and air/CMC systems were used as a liquid media for this study. The concentration of CMC was ranging from 0.5 to 3 w/v. The experimental results show that volumetric oxygen mass transfer coefficient increases with the increase in the superficial gas velocity and impeller speed and decreases with increasing liquid viscosity. The experimental results of kla were correlated with a mathematical correlation des
... Show MoreNumerical investigation has been carried out on heat transfer and friction factor characteristics of copper-water nanofluid flow in a constant heat-fluxed tube with the existence of new configuration of vortex generator using Computational Fluid Dynamics (CFD) simulation. Two types of swirl flow generator: Classical twisted tape (CTT) and Parabolic-cut twisted tape (PCT) with a different twist ratio (= 2.93, 3.91 and 4.89) and different cut depth (= 0.5, 1.0 and 1.5 cm) with 2% and 4% volume concentration
... Show More
The current study was designed to investigate the alterations in the ultrastructure of orgenelles and cellular activity of exocrine pancreatic acini of experimentally induced-diabetic rats and to assess the usefulness of herbal combination supplementation in improving the ultrastructure and cellular activity of exocrine pancreas. The number of albino male rats used were 24 which divided into equally 4 groups; group I: control group, group II: alloxan-induced diabetes mellitus (single intraperitoneal dose of alloxan 120 mg/kg for 3 days), group III: herbal combination treatment composed from the extracts of fenugreek seeds (Trigonella foenum-graecum), black cumin (Nigella sativa) seeds, rhizomes
... Show MoreThis paper presents an analytical study for the magnetohydrodynamic (MHD) flow of a generalized Burgers’ fluid in an annular pipe. Closed from solutions for velocity is obtained by using finite Hankel transform and discrete Laplace transform of the sequential fractional derivatives. Finally, the figures are plotted to show the effects of different parameters on the velocity profile.
Consequence of thermal and concentration convection on peristaltic pumping of hyperbolic tangent nanofluid in a non‐uniform channel and induced magnetic field is discussed in this article. The brief mathematical modeling, along with induced magnetic field, of hyperbolic tangent nanofluid is given. The governing equations are reduced to dimensionless form by using appropriate transformations. Exact solutions are calculated for temperature, nanoparticle volume fraction, and concentration. Numerical technique is manipulated to solve the highly non‐linear differential equations. The roll of different variables is graphically analyzed in terms of concentration, temperature, volume fraction of nanoparticles, axial induced magnetic fie
... Show More