The existing study aimed to assess four soil moisture sensors’ capacitive (WH51 and SKU: S EN0193) and resistive (Yl69 and IC Station) abilities, which are affordable and medium-priced for their accuracy in six common soil types in the central region of Iraq. The readings’ calibration for the soil moisture sensor devices continued through two gravimetric methods. The first depended on the protocols’ database, while the second was the traditional calibration method. The second method recorded the lowest analysis error compared with the first. The moderate-cost sensor WH51 showed the lowest standard error (SE), MAD , and RMSE and the highest R² in both methods. The performance accuracy of WH51 was close to readings shown by the manufacturing company (1%), as the MAD amounted to 1.62%. Through both methods, the average MAD for sensors ranged from 4.76% to 7.36%, with this result considered acceptable, especially for low-cost sensors with insufficient available information for accuracy. In general, the average mean absolute percentage (MAPE) for all sensors was 25.54%, which means that the validity of the measurement for the l ow-cost sensors reached 7 5%. It encourages their use by plant breeders in irrigation, as the error rate was less than the specified depletion of 50% for available water in irrigation, where all study textures showed that the sensor reading reached the limits of 72 (±2), adopting 3% MAD for all sensors. The study affirms that, except for the IC station sensor recommended for irrigation use only in sandy-sandy loam soils, low-cost sensors have suitable accuracy for irrigation management.
Key-frame selection plays an important role in facial expression recognition systems. It helps in selecting the most representative frames that capture the different poses of the face. The effect of the number of selected keyframes has been studied in this paper to find its impact on the final accuracy of the emotion recognition system. Dynamic and static information is employed to select the most effective key-frames of the facial video with a short response time. Firstly, the absolute difference between the successive frames is used to reduce the number of frames and select the candidate ones which then contribute to the clustering process. The static-based information of the reduced sets of frames is then given to the fuzzy C-Means algor
... Show MoreThe primary aim of the study was to find out the values of some biomechanical variables for the long serve skill in badminton and to identify the effect of biomechanical feedback on the performance of long serve. The present study had a single group, pre-post experimental study design. The research community was determined by the intentional method of one group with a pre-and post-test. The players of the Assyrian badminton club constituted the research community. A total of 12 players were present in the research community. The badminton players falling within the age group of 15-17 years for the season 2020-2021 were recruited as the participants for the study. A total of five players were selected as the participant
... Show MoreAbstract
The use of electronic valves is commonly available. yet, the most
common is the techniques of communications as prod casting transmitter that
are used by these valves in addition to their use in communication tools as far
distance telephone, electronic measuring techniques , and others.
In this study, an attempt is endeavored for improving the efficiency of the
vacuum micro- valves(GI-19b) through activating their internal surfaces by the
use of ionic pumping which is used for treating valves which are out of order
(because of sedimentation some materials and oxide on its poles). The
existence of these materials and oxide increase the sum of current leakage
moving in between. The use of ionic pumpin
The coronavirus-19 (COVID-19) pandemic, triggered by the severe acute respiratory syndrome coronavirus 2, has affected over 100 million people and killed around 2 million individuals. One of the most common chronic illnesses in the world is diabetes, which greatly raises the risk of hospitalization and death for COVID-19 patients.
This study aims to analyze the novel coronavirus's general characteristics and shed light on COVID-19 and its management in diabetic individuals by measuring some metabolic and inflammatory factors in type 2 diabetic pa
Abstract:
The research aimed to know favoured mass media for children and
modifying their behaviour ,the child became aquires the information from
mass media that he exposure them without any guidance , where upon the
quidance proqrammes becomes real danger whereas qet out their civil
style and converting to deadly poisons,and because of little study for this
supject the two researchers opined to perform astudy to know the favoured
mass media to the children and what are the mass media that modify their
behavior according to ther parent points of view ,after propring the research
measurement and the suilable statical methods it has shown that there are
mass media affect in children behavior ,they are st
A survey of entomopathogenic and other opportunistic fungi isolated from soil samples collected from insect hibernation sites in different habitats in Kurdistan region of Iraq was carried out during October to December 2009. By using dilution plate method, two entomopathogenic species (Beauveria bassiana (Bals.) Vuill.and Isaria javanica (Friedrichs & Bally) Samson & Hywel-Jones) were detected with isolation percentage (38.46%) each. Other opportunistic fungi such as Alternaria alternata, Aspergillus flavus, A.niger, Penicillium glabrum, P. digitatum, Rhizopus stolonifer and Syncephalastratum racemosum
This study's objective is to assess how well UV spectrophotometry can be used in conjunction with multivariate calibration based on partial least squares (PLS) regression for concurrent quantitative analysis of antibacterial mixture (Levofloxacin (LIV), Metronidazole (MET), Rifampicin (RIF) and Sulfamethoxazole (SUL)) in their artificial mixtures and pharmaceutical formulations. The experimental calibration and validation matrixes were created using 42 and 39 samples, respectively. The concentration range taken into account was 0-17 μg/mL for all components. The calibration standards' absorbance measurements were made between 210 and 350 nm, with intervals of 0.2 nm. The associated parameters were examined in order to develop the optimal c
... Show More