Preferred Language
Articles
/
AxdowpEBVTCNdQwCCZpj
Determination of the Accuracy of Salivary Biomarkers for Periodontal Diagnosis
...Show More Authors

Background: We aimed to investigate the accuracy of salivary matrix metalloproteinases (MMP)-8 and -9, and tissue inhibitor of metalloproteinase (TIMP)-1 in diagnosing periodontitis and in distinguishing periodontitis stages (S)1 to S3. Methods: This study was a case–control study that included patients with periodontitis S1 to S3 and subjects with healthy periodontia (controls). Saliva was collected, and then, clinical parameters were recorded, including plaque index, bleeding on probing, probing pocket depth, and clinical attachment level. Diagnosis was confirmed by assessing the alveolar bone level using radiography. Salivary biomarkers were assayed using an enzyme-linked immunosorbent assay. Results: A total of 45 patients (15 for each stage) and 18 healthy subjects as controls were included. The levels of all salivary biomarkers and clinical parameters were significantly higher in periodontitis subjects than in the controls. The ROC curve showed that MMP-8, MMP-9, TIMP-1, MMP-8/TIMP-1, and MMP-9/TIMP-1 had statistically significant diagnostic accuracy, with areas under the curve (AUCs) of 0.892, 0.844, 0.920, 0.986, and 1.000, respectively, when distinguishing periodontitis from the controls. Similarly, these biomarkers showed significant diagnostic accuracy in the differentiation of S1 periodontitis from the controls (AUC range from 0.902 to 1.000). Conclusions: This study suggested that salivary biomarkers exhibited high diagnostic accuracy in distinguishing periodontal health from periodontitis in general as well as S1 periodontitis. Furthermore, TIMP-1 could differentiate S1 from S3.

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Aug 30 2020
Journal Name
Turkish Journal Of Agriculture - Food Science And Technology
Determination of Operating Characteristics of 540 and 540E PTO Applications in Disc Type Silage Machines
...Show More Authors

In this study, performance characteristics such as power take off (PTO) power consumption, fuel consumption, fuel consumption for the unit field-unit product were determined at different working speeds with two different PTO applications (540 and 540E) in a single row disc type silage machine. In particular, the 540E PTO application greatly reduces fuel consumption for unit work. The best results in terms of hourly fuel consumption were achieved in 540E PTO application and V1 working speed. When the field - product fuel consumption is evaluated, the best results were obtained with the 540E PTO application at the V3 working speed. When an evaluation is made considering all the parameters, it is concluded that the 540E PTO application will p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Iraqi J Of Agricultural Science
Determination of Beta Lactam Resistance of Klebsiella Pneumoniae Isolated from Clinical Specimens and Water Samples
...Show More Authors

Scopus (3)
Scopus
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Optimization of Voltammetric Determination of Dysprosium (III) Using Plackett-Burman and RSM-CCD Experimental Designs
...Show More Authors

This study was aimed to develop an optimized Dy determination method using differential pulse voltammetry (DPV). The Plackett-Burman (PB) experimental design was used to select significant factors that affect the electrical current response, which were further optimized using the response surface method-central composite design (RSM-CCD). The type of electrolyte solution and amplitude modulation were found as two most significant factors, among the nine factors tested, which enhance the current response based on PB design. Further optimization using RSM-CCD shows that the optimum values for the tw

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Biochemical And Cellular Archives
Determination of Beta Lactam Resistance of Klebsiella pneumoniae isolated from clinical specimens and water samples
...Show More Authors

Preview PDF
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Determination of the Elastic and Viscous Behavior of Polycarbonate Melts at Different Temperatures and Their Relationship to the Steady State Viscosity via the Cox-Merz Rule
...Show More Authors

Rheological instrument is one of the basic analytical measurements for diagnosing the properties of polymers fluids to be used in any industry. In this research polycarbonate was chosen because of its importance in many areas and possesses several distinct properties.
Two kinds of rheometers devices were used at different range of temperatures from 220 ˚C-300 ˚C to characterize the rheological technique of melted polycarbonate (Makrolon 2805) by a combination of different investigating techniques. We compared the results of the linear (oscillatory) method with the non-linear (steady-state) method; the former method provided the storage and the loss modulus of melted polycarbonate, and presented the Cox-Merz model as well. One of the

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Evaluation of the Organic-Pollution Based on the Determination of some Polycyclic Aromatic Hydrocarbons(PAHs) in Tigris River Water in 2012 at Baghdad City , Iraq
...Show More Authors

This study aims to predict the organic pollution produced from the presence of some polycyclic aromatic hydrocarbons (PAHs) and determination it's concentrations (µg/L , ppb) in Tigris river water by a collection twenty-seven water samples from a selected three stations with nine sampling sites and three depths of water (5 cm , 2 m and 4 m) each site for 4.6 km distance of a geographic studied area which is located between the ( Al-Senak and AL-Sarrafiah bridges ) at Baghdad city – Iraq on May, 2012. The geographic location was determined with a Global Positioning System (GPS) and Geographic Information System (GIS) software program. The concentrations of fourteen components (PAHs) were performed using the reverse phase

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Determination of Some Volatile Organic Compounds in the water produced at Al-Ahdab oilfield in the Governorate of Wasit, Iraq using Headspace SPE-GC-FID
...Show More Authors

The study was conducted over the period of Oct 2018 to Apr 2019 and is aimed for the detection and estimation of four hazardous Volatile Organic Compounds VOC (benzene, toluene, ethylbenzene, and xylene) so-called (BTEX) in samples collected from the produced water in the Al-Ahdab oil field in Iraq also to track their availability in the important natural water sources around the field. These compounds pose a risk to human health as well as environment. To avoid the laborious and tiresome conventional extraction methods, water samples were collected and concentrated using solid-phase extraction technique (SPE) which is a robust and cost-effective method of sample extraction with minimal exposure and handling of solvents and then to be analy

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Mon Dec 20 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY THE PHYSICAL AND CHEMICAL PROPERTIES AND DETERMINATION THE CYTOTOXICITY OF KOJIC ACID PRODUCED FROM THE LOCAL ISOLATE ASPERGILLUS FLAVUS WJF81 AND THEIR EFFECTS ON CONSUMER HEALTH.: STUDY THE PHYSICAL AND CHEMICAL PROPERTIES AND DETERMINATION THE CYTOTOXICITY OF KOJIC ACID PRODUCED FROM THE LOCAL ISOLATE ASPERGILLUS FLAVUS WJF81 AND THEIR EFFECTS ON CONSUMER HEALTH.
...Show More Authors

Steps were taken to obtain the Kojic acid crystals from local fungal isolation A. flavus WJF81 by separating the fermentation products from the fungus mycelium from the production plant at the centrifuge at a speed of 5000 cycles for 10 minutes. The extraction was followed by ethyl acetate then supernatant concentrate by using rotary evaporator, and dried with heat oven 37ºC. Long, yellowish, pristine acid crystals were obtained that examined the optical microscope with a magnification force of 10x and 40x. The melting point of kojic acid was determined between 152.9-153.5 °C Results of the diagnosis of Kojic acid by applying High pressure liquid chromatography HPLC technique showed that the acid was at one peak, which was close to the

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 12 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of the Impact of Electronic Health Information Systems upon Medical, Medical Backing and Administrative Business Fields in Al-Kindy Teaching Hospital
...Show More Authors

Objective(s): To determine the impact of the Electronic Health Information Systems upon medical, medical backing and administrative business fields in Al-Kindy Teaching Hospital and to identify the relationship between such impact and their demographic characteristics of years of employment, place of work, and education. Methodology: A descriptive analytical design is employed through the period of April 25th 2016 to May 28th 2016. A purposive "non- probability" sample of (50) subject is selected. The sample is comprised of (25) medical and medical backing staff and (25) administrative staff who are all

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Extraction and Determination of Amygdaline in Iraqi Plant Seeds Using the Combined Simple Extraction Procedure and High-Performance Liquid Chromatography
...Show More Authors

Abstract :In this study, amygdaline in Iraqi plant seeds was extracted and isolated from their seeds matrix using reflux procedure and subsequently identified and determined by high performance liquid chromatography (HPLC) on reversed phase column of LC-18 (150mm x 4.6mm, 5?m )with actonitrile :water ( 50 : 50 ) as mobile phase at flow rate of ( 0.5 mL/min ) and detection at wavelength of 215 nm.The experimental results indicated that the linearity of calibration is in the range of 1.0-30.0 mg L-1amygdaline with the correlation coefficient of 0.9949. The limit of detection (LOD) and limit of quantitation (LOQ) for amygdaline were of 0.88 and 2.93 mg L-1 in standard pure sample. The mean recovery percent is 97.34±0.58 at 95% confidence inte

... Show More
View Publication Preview PDF
Crossref (2)
Crossref