Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show MoreThe Non-thermal plasma has a wide range of applications in different areas. In this study, the oxidation of a model fuel containing organo-sulfur compounds (benzothiophene and dibenzothiophene) was investigated using plasma. The process involved ozone generation through dielectric barrier discharge, followed by extraction using acetonitrile. The results demonstrated the efficient oxidation and removal of dibenzothiophene and benzothiophene by non-thermal plasma. The desulfurization efficiency reached 93.78% under the optimum conditions, including a voltage of 11Kv, temperature of 50ºC, duration of 4 hours, and a flow rate of 75 ml/min.
The current research aims to identify the effect of the study hand-on strategy on the achievement of the chemistry subject at the first grade students in the government day schools. The Umm al-Mu 'mineen school was chosen by appointment the intentional, so that its student is the research sample of the second Rusafa Directorate for the academic year (2021-2022). Then, two divisions were randomly selected for the first average out of 6 divisions to represent the experimental group that is studying according to the strategy of the thinker hand and the other the control group that is studying according to the usual method. The equivalence of the two research groups was verified by a set of variables represented by (chronological age, previous
... Show MoreThe current research aims to identify the effect of the hands_on strategy on the life effectiveness skills of the first grade students in the government's daytime middle schools. The Umm al-Mu 'minin school was intentionally chosen to be the research sample of the second Rusafa Directorate for the academic year 2021-2022. Then, two divisions were randomly chosen for the first of the six divisions to represent the experimental group that is studying according to the strategy of the hands_on and the other the control group that is studying according to the usual method. The equivalence of the two research groups was verified by a set of variables. The two groups were found to be equivalent. As for the research tool, the life effectiveness sca
... Show MoreBackground: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.
Electrochemical Grinding (ECG) process is a mechanically assisted electrochemical process for material processing. The process is able to successfully machine electrically conducting harder materials at faster rate with improved surface finish and dimensional control. This research studies the effect of applied current, electrolyte concentration, spindle speed and the gap between workpiece and tool on hardness and material removal rate during electrochemical grinding for stainless steel 316. The characteristic features of the electrochemical grinding process are explored through Taguchi-design-based experimental studies. The better hardness can be obtained at 10 A of the current, 150 g/l of the electrolyte concentration, 0.3 mm of gap an
... Show MoreNanocrystalline TiO 2 and CuO doped TiO 2 thin films were successfully deposited on suitably cleaned glass substrate at constant room temperature and different concentrations of CuO (0.05,0.1,0.15,0.2) wt% using pulse laser deposition(PLD) technique at a constant deposition parameter such as : (pulse Nd:YAG laser with λ=1064 nm, constant energy 800 mJ, with repetition rate 6 Hz and No. of pulse (500). The films were annealed at different annealing temperatures 423K and 523 K. The effect of annealing on the morphological and electrical properties was studied. Surface morphology of the thin films has been studied by using atomic force microscopes which showed that the films have good crystalline and homogeneous surface. The Root M
... Show MoreThe present study discusses the problem based learning in Iraqi classroom. This method aims to involve all learners in collaborative activities and it is learner-centered method. To fulfill the aims and verify the hypothesis which reads as follow” It is hypothesized that there is no statistically significant differences between the achievements of Experimental group and control group”. Thirty learners are selected to be the sample of present study.Mann-Whitney Test for two independent samples is used to analysis the results. The analysis shows that experimental group’s members who are taught according to problem based learning gets higher scores than the control group’s members who are taught according to traditional method. This