he aim of this study is to get a plant extracts to use it as molluscicides to control the snail vector of Schistosomiasis andfinely control the disease. Laboratory study was performed to compare the molluscicidal activity of leaves and stems extractsof Cucumis melo against Bulinus truncatus snail. The snail B. truncatus was exposed to a serial concentrations of leaves andstems extracts (4000ppm, 5000ppm) in this work. Different effects of the extracts to the snail B. truncatus were recorded.These effects includes death, escaping and imbalance of snail behavior. 96hr-LD50 values of leaves extracts were calculatedfor the doses 4000 and 5000ppm as (76 and 37%) respectively while for stems were (105 and 47%) respectively. We found thatthe snail B. truncatus was more susceptible to leaves than stems extracts. The Molluscicidal activity of C. melo extractsdepended on increase of extract concentrations and time of exposure (p>0.05) (2) (PDF) Schistosomiasis vector control using cucumis melo plantextractswithbioassayexperiment. Available from: https://www.researchgate.net/publication/326097198_Schistosomiasis_vector_control_using_cucumis_melo_plantextractswithbioassayexperiment [accessed Apr 08 2023].
Thirty nine hyperlipoproteinemic (HPLic) male subject aged (48-63) year not on any of the lipid lowering drugs, attending out patient clinic at Baghdad Teaching Hospital, were included in the present study, in addition to twenty two normolipidimic male subjects of matched age were included as control throughout this study. The first part of this study was devoted to the classification of the HPLic subjects according to the serum lipid and lipoprotein profile following defined criteria. The lipid parameter including total cholesterol (TC), triglyceride (TG), high density lipoprotein (HDL) and low density lipoprotein (LDL) were investigated in serum of HPLic subjects included in the study. The classification was performed according to Fred
... Show MoreIn every country in the world, there are a number of amputees who have been exposed to some accidents that led to the loss of their upper limbs. The aim of this study is to suggest a system for real-time classification of five classes of shoulder girdle motions for high-level upper limb amputees using a pattern recognition system. In the suggested system, the wavelet transform was utilized for feature extraction, and the extreme learning machine was used as a classifier. The system was tested on four intact-limbed subjects and one amputee, with eight channels involving five electromyography channels and three-axis accelerometer sensor. The study shows that the suggested pattern recognition system has the ability to classify the sho
... Show MoreIn the last few years, there have been a lot of changes in the economy, society, and the environment. This has led to much competition between companies, directly and indirectly affecting production and marketing processes. Most companies are trying to cut production and manufacturing costs by using modern cost techniques such as product life cycle costing and Continuous Improvement (Kaizen) technology, in the method of measuring production costs or service costs, and the need for internal control to keep an eye on how these technologies are being used and how well they work. And to find out the effect of internal control on the implementation of costing techniques in Iraqi companies, 64 questionnaires were given to people who work in the i
... Show MoreAerial manipulation of objects has a number of advantages as it is not limited by the morphology of the terrain. One of the main problems of the aerial payload process is the lack of real-time prediction of the interaction between the gripper of the aerial robot and the payload. This paper introduces a digital twin (DT) approach based on impedance control of the aerial payload transmission process. The impedance control technique is implemented to develop the target impedance based on emerging the mass of the payload and the model of the gripper fingers. Tracking the position of the interactional point between the fingers of gripper and payload, inside the impedance control, is achieved using model predictive control (MPD) approach.
... Show MoreIntroduction: Infection control or hospital-acquired infections are the major concern of the health care system and agencies. Critical care nurses are on the first-line contact with the patients, so on, they are most vulnerable to acquired infections. It is really important to regularly check their knowledge and practices concerning infection control. Objectives: The study aims to identify the impact of years’ experience on nurses’ knowledge and practices concerning infection control in three hospitals and center (Baghdad teaching hospital, Ibn Al-Nafees hospital, and Ibn al-Bitar center) Methodology: Cross-sectional study was conducted, the study starting from 4th of July 2020 to 13th of November 2020. Non-probability (purposive) sampl
... Show MoreObjectives: This study explored knowledge, attitude, and practice of infection control by dental students at College of Dentistry/ University of Baghdad, Iraq. Material and Methods: Three hundred dental students participated in this study. A self administrated questionnaire with 21 close ended questions related to use of personal protective equipments, infection control awareness, vaccination status, percutaneous exposures, and attitude towards treatment of patients with hepatitis B (HBV)/ or human immunodeficiency virus (HIV) was distributed to dental students. Data were analyzed using Statistical Package for Social Sciences (SPSS) version 21. Fisher exact and Chi-square test were used with significance level set to 0.05. Results: The
... Show MoreThe
Abstract. This work presents a detailed design of a three-jointed tendon-driven robot finger with a cam/pulleys transmission and joint Variable Stiffness Actuator (VSA). The finger motion configuration is obtained by deriving the cam/pulleys transmission profile as a mathematical solution that is then implemented to achieve contact force isotropy on the phalanges. A VSA is proposed, in which three VSAs are designed to act as a muscle in joint space to provide firm grasping. As a mechatronic approach, a suitable type and number of force sensors and actuators are designed to sense the touch, actuate the finger, and tune the VSAs. The torque of the VSAs is controlled utilizing a designed Multi Input Multi Output (MIMO) fuzzy controll
... Show More