Preferred Language
Articles
/
Axb4xYkBVTCNdQwCBo2C
Simple RP-HPLC Method for Estimation of Furosemide, Carbamazepine, Diazepam and Carvedilol in Bulk and Pharmaceutical Dosage Forms
...Show More Authors

A simple reverse-phase high performance liquid chromatographic method for the simultaneous analysis (separation and quantification) of furosemide (FURO), carbamazepine (CARB), diazepam (DIAZ) and carvedilol (CARV) has been developed and validated. The method was carried out on a NUCLEODUR® 100-5 C18ec column (250 x 4.6 mm, i. d.5μm), with a mobile phase comprising of acetonitrile: deionized water (50: 50 v/v, pH adjusted to 3.6 ±0.05 with acetic acid) at a flow rate 1.5 mL.min-1 and the quantification was achieved at 226 nm. The retention times of FURO, CARB, DIAZ and CARV were found to be 1.90 min, 2.79 min, 5.39 min and 9.56 min respectively. The method was validated in terms of linearity, accuracy, precision, limit of detection and limit of quantitation. The developed method was successfully applied for the estimation of furosemide, carbamazepine, diazepam and carvedilol in bulk and in pharmaceutical dosage forms.

Publication Date
Tue Oct 01 2019
Journal Name
International Journal Of Drug Delivery Technology
Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the

... Show More
Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
Aesthetic references for reductive forms in contemporary Iraqi sculpture
...Show More Authors

Reduction has been linked visually in art since man began making functional and aesthetic forms, and this beginning can be identified with cave paintings. Reduction is one of the clearest indications of intellectual presence in aesthetic experience. Modernism was greatly supported by the great transformations that the intellectual movement witnessed in the world in general and in Europe in particular. There, and their transfer of European artistic experiences, and the reflection of this influence in their aesthetic sculptures, and for this reason the researchers find that the study of the aesthetic references of the reductive forms in the Iraqi sculptural experience represents a great importance in the study of the history of contemporar

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
Aesthetic references for reductive forms in contemporary Iraqi sculpture
...Show More Authors

Reduction has been linked visually in art since man began making functional and aesthetic forms, and this beginning can be identified with cave paintings. Reduction is one of the clearest indications of intellectual presence in aesthetic experience. Modernism was greatly supported by the great transformations that the intellectual movement witnessed in the world in general and in Europe in particular. There, and their transfer of European artistic experiences, and the reflection of this influence in their aesthetic sculptures, and for this reason the researchers find that the study of the aesthetic references of the reductive forms in the Iraqi sculptural experience represents a great importance in the study of the history of contem

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More
Publication Date
Thu Dec 09 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and In vitro Characterization of Aceclofenac Nanosuspension (ACNS) for Enhancement of Percutaneous Absorption using Hydrogel Dosage Form
...Show More Authors

         Aceclofenac (AC) is an orally active phenyl acetic acid derivative, non-steroidal anti-inflammatory drug with exceptional anti-inflammatory, analgesic and antipyretic properties. It has low aqueous solubility, leading to slow dissolution, low permeability and inadequate bioavailability. The aim of the current study was to prepare and characterize AC-NS-based gel to enhance the dissolution rate and then percutaneous permeability. NS.s were prepared using solvent/antisovent precipitation method at different drug to polymer ratios (1:1, 1:2, and 1:3) using different polymers such as poly vinyl pyrrolidone (PVP-K25), hydroxy propyl methyl cellulose (HPMC-E5) and poloxamer® (388) as stabilizer

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (3)
Scopus Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
Azo Coupling Reaction for indirect Spectrophotometric Determination of Furosemide using Resorcinol as a Reagent
...Show More Authors
Abstract<p>A simple and accurate method to determinate furosemide (FUR) based on converting the secondary amine to primary amine with acidic hydrolysis then azotization by nitrous acid and coupled with resorcinol as a coupling agent in aqueous medium at pH 13. The optical characteristic like beers law limit found to be (0.25-2.5) μg.ml<sup>−1</sup>, detection and quantification limits (0.0196) (0.0654) μg.ml<sup>−1</sup>respectivly and Sandel sensitivity was 0.006738 μg.cm<sup>−2</sup>. The least-square method was used to evaluate the regression equation and the correlation coefficient. The resulted azo dye has a maximum absorbance at 430 nm with light oran</p> ... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ULATRAVIOLET ABSORBANCE SEPECTRA FOR ANTIBIOTIC DERIVATIVES (AMINO GLYCOSIDES) USED IN MEDICAL AND PHARMACEUTICAL INDUSTRY: ULATRAVIOLET ABSORBANCE SEPECTRA FOR ANTIBIOTIC DERIVATIVES (AMINO GLYCOSIDES) USED IN MEDICAL AND PHARMACEUTICAL INDUSTRY
...Show More Authors

Ultraviolet spectrophotometric studies for antibiotic (amino glycoside) derivatives including, Neomycin, Streptomycin, Gentamycin and Kanamycin with special reagents, which are benzoyl chloride; benzene sulfonyl chloride, toluenesulfonyl chloride and phthalic anhydride were made. Amino glycosides derivatives were followed through measurements of the ultraviolet absorbance (A) from which the absorptivity (ε) of the complexes was deduced and molar absorbances using Ultraviolet for products and calculate the number of reagents molecule that combine to amino glycosides.

View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations
...Show More Authors

The present study describes employing zero-, 1st - and 2nd -order derivative spectrophotometric methods have been developed for determination of lorazepam (LORA) and clonazepam (CLON) in commercially available tablets. LORA was determined by means of 1st (D1), 2nd (D2) derivative spectrophotometric techniques using zero cross, peak height, and Peak area. D1 used for the determination of CLON by using zero cross and peak height while D2 (zero cross) was used for the determination of CLON. The method was established to be linear in concentration containing different ratios of LORA and CLON range of (20-200 mg/L) and (5-35 mg/L) at wavelength range (250 -370 nm), (210-370nm) respectively. The proposed techniques are highly sensitive, precise a

... Show More
Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations.
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Batch and flow injection spectrophotometric methods for determination of Ceftazidime in pharmaceutical formulations
...Show More Authors

It is generally accepted that there are two spectrophotometric techniques for quantifying ceftazidime (CFT) in bulk medications and pharmaceutical formulations.  The methods  are described as simple, sensitive, selective, accurate and efficient techniques. The first method used an alkaline medium to convert ceftazidime to its diazonium salt, which is then combined with the 1-Naphthol (1-NPT) and 2-Naphthol (2-NPT) reagents. The azo dye that was produced brown  and red in color with absorption intensities of ƛmax 585 and 545nm respectively. Beer's law was followed in terms of concentration ranging from  (3-40) µg .ml-1 For (CFT-1-NPT) and (CFT-2-NPT), the detection limits were 1.0096 and 0.8017 µg.ml-1, respec

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref