Background: This in vitro study compares a self-etch primer (SEP) to an etch-and-rinse (EaR) for bonding sapphire brackets by evaluation of the enamel etch-pattern, shear bond strength, amount of remnant adhesive and enamel surface damage following thermal and fatigue cyclic loading. Material and Methods: Ceramic (sapphire) brackets were bonded to 80 extracted human premolars using two enamel etching protocols: conventional EaR using 37% phosphoric acid (PA) gel (control), and a SEP (Transbond Plus). Each group was subdivided into two subgroups (n=20 teeth) according to the time of bracket debonding: after 24 h water storage or following 5000 thermo-cycles plus 5000 cycles fatigue loading, to determine the shear bond strength (SBS), adhesive remnant index (ARI score), with scanning electron microscopy (SEM) evaluation of enamel condition. Results: The control subgroups consistently exhibited significantly higher (p ˂ 0.05) SBS mean values (23.4-29.8 MPa) than the SEP subgroups (15.1-22.4 MPa) at both bracket debonding time points. However, the SEP subgroups yielded milder etch-patterns and attained SBS values above the minimum requirement range for clinical performance. In addition, the higher SBS of control subgroups was accompanied with higher ARI scores and enamel damage grades than SEP subgroups as confirmed by SEM. Thermocycling and fatigue significantly reduced the SBS of all subgroups, with a non-significant drop in the amount of adhesive residue or enamel damage. Conclusions: The use of SEP can be a suitable alternative to the conventional PA gel for sapphire bracket bonding as it maintains suitable bond strength and has the potential to produce both less remnant adhesive and enamel damage
This paper addresses the substrate temperature effect on the structure, morphological and optical properties of copper oxide (CuO) thin films deposited by pulsed laser deposition (PLD) method on sapphire substrate of 150nm thickness. The films deposited at two different substrate temperatures (473 and 673)K. The atomic force microscopy (AFM), Fourier transform infrared spectroscopy (FTIR) and UV-VIS transmission spectroscopy were employed to characterize the size, morphology, crystalline structure and optical properties of the prepared thin films. The surface characteristics were studied by using AFM. It is found that as the substrate temperature increases, the grain size increased but the surface roughness decreased. The FTIR spec
... Show MoreBackground: Aflatoxin B1 (AFB1) is a widely distributed mycotoxin in nature. Several investigations have shown its biological effects on different organs and in different animal species. However, the effects of AFB1 on the rat kidney have not been much elucidated histologically.
Objective: This study aims to demonstrate the effects of AFB1 contaminated diet on the rat kidney from
the histological and morphometric aspects.
Method: Twelve mature albino rats were divided equally into a control group fed with usual diet and a treated group which was daily fed with diet contaminated with 20 mg AFB1/kg of body weight for 30 days. Semithin sections from renal cortex were stained with methylene blue and examined by l
The objective of the investigation was to analyze the structure and administration of the political system in Iraq (post-ISIS). After 2003, the Iraqi political system suffered the fundamental problem of its failure to achieve the political and social inclusion that characterizes democratic systems, to guarantee the establishment of a "state for all", while respecting differences. Political representation has moved from the system of sectarian ethnic components, under the title of consensual democracy, to the representation of leaders and the realization of their interests and the interests of their parties at the expense of the groups that claim to represent them, which complicates the problem. In this sense, the new political syste
... Show MoreFatigue cracking is the most common distress in road pavement. It is mainly due to the increase in the number of load repetition of vehicles, particularly those with high axle loads, and to the environmental conditions. In this study, four-point bending beam fatigue testing has been used for control and modified mixture under various micro strain levels of (250 μƐ, 400 μƐ, and 750 μƐ) and 5HZ. The main objective of the study is to provide a comparative evaluation of pavement resistance to the phenomenon of fatigue cracking between modified asphalt concrete and conventional asphalt concrete mixes (under the influence of three percentage of Silica fumes 1%, 2%, 3% by the weight of asphalt content), and (chan
... Show MoreTo determine the evaluation of education program on women's knowledge regarding managing BSE. The present quasi- experimental study, Non-probability (purposive), sample consisting of (260) women who are employee, and students in both colleges (Nursing college, Medical and Health Techniques College). The sample consist of two groups, study group (130) including those in (Nursing college), and control group (130) in (Medical and Health Techniques College). A questionnaire was constructed which included, Demographic information, Reproductive information, Family history, Previous medical history, and information about women's knowledge toward management of breast self examination (BSE). Instrument validity and reliability was determined. Data w
... Show MoreBackground: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), the effect of post types ( Manually Milled Zirconia post, Prefabricated Fiber post, prefabricated Zirconia post) and the type of cement used (GIC, self-adhesive resin cement) on the bond strength between the posts and root dentin by using push-out test. Material and methods: Forty eight mandibular premolars extracted for orthodontic reasons (single rooted) were instrumented with ProTaper system (hand use) and obturated with gutta percha for ProTaper using AH26® root canal sealer following the manufacturer instructions. After 24 hours, post space was prepared using Zirix and Glassix drills no.3 creating 8 mm dept
... Show MoreBackground: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl
... Show MoreBackground: The aims of the study were to evaluate the unclean/clean root canal surface areas with a histopathological cross section view of the root canal and the isthmus and to evaluate the efficiency of instrumentation to the isthmus using different rotary instrumentation techniques. Materials and Methods:The mesial roots of thirty human mandibular molars were divided into six groups, each group was composed of five roots (10 root canals)which prepared and irrigated as: Group one A: Protaper system to size F2 and hypodermic syringe, Group one B: Protaper system to size F2 and endoactivator system, Group two A:Wave One small then primary file and hypodermic syringe, Group two B:Wave One small then primary file and endoactivator system, Gr
... Show MoreBilastine (BL) is a novel non-sedating second-generation antihistamine, and its bioavailability is about 60%. Objective: To compare the bioavailability of prepared oral self-nanoemulsions of BL (BL-SNE) with that of pure BL and marketed tablets. Methods: Four groups of Wistar rats were used in this study, each with six rats weighing between 200 and 250 g. They were treated orally using a a gavage tube. The groups were fed either with conventional tablets ("Alerbix®") after being ground and dispersed with deionized water (DIW), treated with BL-SNE or fed with pure BL powder suspension. The fourth group did not receive any medication. The concentration of BL in the rat’s plasma was measured using HPLC. We used Trandolapril as an an interna
... Show MoreThe current research aims to identify "the impact of the round table strategies and the question of self-achievement and self-efficacy among students of the Faculty of Education in research methodology course.” The research sample consisted of (75) male and female-third stage students in the department of Life Sciences / College of Education for Pure Sciences / University of Dhi Qar for the academic year (2018-2019. The researcher adopted the experimental approach to achieving the study objectives. The researcher prepared two tools: the achievement test and the self-efficacy scale were applied to the collected sample to obtain the needed data. The result showed that there was a statistically significant difference at the level (0.05) b
... Show More