In this work, an efficient energy management (EEM) approach is proposed to merge IoT technology to enhance electric smart meters by working together to satisfy the best result of the electricity customer's consumption. This proposed system is called an integrated Internet of things for electrical smart meter (2IOT-ESM) architecture. The electric smart meter (ESM) is the first and most important technique used to measure the active power, current, and energy consumption for the house’s loads. At the same time, the effectiveness of this work includes equipping ESM with an additional storage capacity that ensures that the measurements are not lost in the event of a failure or sudden outage in WiFi network. Then then these measurements are sent using the internet of thing (IoT) technology to Google Firebase cloud, where the electric consumer's service center is located to store, analyze the measured data, and detect cases of energy penetration when it exceeds 53 and the cases of the electrical energy theft if any below 20 and then take the appropriate decision about it. Finally, an electric smart metering application (ESM-app) is designed and implemented to read and pull data information from the Google firebase cloud and then send the electric bill to the end consumer, and sending alert messages to the thieves and electrical power hackers to prohibit them if something wrong has detected. In this work, an efficient energy management (EEM) approach is proposed to merge IoT technology to enhance electric smart meters by working together to satisfy the best result of the electricity customer's consumption. This proposed system is called an integrated Internet of things for electrical smart meter (2IOT-ESM) architecture. The electric smart meter (ESM) is the first and most important technique used to measure the active power, current, and energy consumption for the house’s loads. At the same time, the effectiveness of this work includes equipping ESM with an additional storage capacity that ensures that the measurements are not lost in the event of a failure or sudden outage in WiFi network. Then then these measurements are sent using the internet of thing (IoT) technology to Google Firebase cloud, where the electric consumer's service center is located to store, analyze the measured data, and detect cases of energy penetration when it exceeds 53 and the cases of the electrical energy theft if any below 20 and then take the appropriate decision about it. Finally, an electric smart metering application (ESM-app) is designed and implemented to read and pull data information from the Google firebase cloud and then send the electric bill to the end consumer, and sending alert messages to the thieves and electrical power hackers to prohibit them if something wrong has detected.
The research aims to statement the main obstacles that prevent the application of total quality management (TQM) in a number of Iraqi service organizations, and by one organization in each of the sectors (health, finance, education, higher education, tourism), which are, (Al-Yarmouk Teaching Hospital, Rafidain Bank/ Branch of Hay Al-Arabi Al-Jadid, Al-Karkh/1 Directorate of Education, College of administration and Economics/ Baghdad University, International Palestine Hotel). The research also, tries to classify the priority of the obstacles depending on the type of service organization surveyed. And diagnoses the extent to which or the difference of the research sample members views on the order of obstacles of TQM, and also proposes a
... Show MoreThe intelligent buildings provided various incentives to get highly inefficient energy-saving caused by the non-stationary building environments. In the presence of such dynamic excitation with higher levels of nonlinearity and coupling effect of temperature and humidity, the HVAC system transitions from underdamped to overdamped indoor conditions. This led to the promotion of highly inefficient energy use and fluctuating indoor thermal comfort. To address these concerns, this study develops a novel framework based on deep clustering of lagrangian trajectories for multi-task learning (DCLTML) and adding a pre-cooling coil in the air handling unit (AHU) to alleviate a coupling issue. The proposed DCLTML exhibits great overall control and is
... Show MoreIn this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the D
... Show MoreThis research aims at calculating the optimum cutting condition for various types of machining methods, assisted by computers, (the computer program in this research is designed to solve linear programs; the program is written in v. basic language). The program obtains the results automatically, this occur through entering the preliminary information about the work piece and the operating condition, the program makes the calculation actually by solving a group of experimental relations, depending on the type of machining method (turning, milling, drilling). The program was transferred to package and group of windows to facilitate the use; it will automatically print the initial input and optimal solution, and thus reduce the effort and t
... Show MoreAbstract A descriptive study was carried out on nurses who were working at burn. Units in Baghdad city hospitals, Al-Kindy , Al-Yarmook, Al-Qadisiya, Al-karkh, and Al-Karama hospital, in the period from 20th july 2003 to 20th November 2003. The study aimed to identify the nurses performance about pain management for burned patients at burn units and find out the relationship between the demographic characteristics and performance . A purposive (non-probability) sample of (40) nurses, (24) male nurses and (16) female. The data were collected through the use of observational checklist, which comprised (
The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decr
... Show MoreConsider the (p,q) simple connected graph . The sum absolute values of the spectrum of quotient matrix of a graph make up the graph's quotient energy. The objective of this study is to examine the quotient energy of identity graphs and zero-divisor graphs of commutative rings using group theory, graph theory, and applications. In this study, the identity graphs derived from the group and a few classes of zero-divisor graphs of the commutative ring R are examined.