Preferred Language
Articles
/
AYZMsoYBIXToZYALRrEe
Drinking Water Assessment Using Statistical Analyses of AL-Muthana Water Treatment Plant
...Show More Authors

ENGLISH

Crossref
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Using Ultrasonic Pulse Velocity Test to Assess the Effect of Water-Cement Ratio on the Compressive Strength of Concrete
...Show More Authors

This study aims to find the effect of water-cement ratio on the compressive strength of concrete by using ultrasonic pulse velocity test (UPVT). Over 230 standard cube specimens were used in this study, with dimensions of 150mm, and concrete cubes were cured in water at 20 °C. Also, the specimens used in the study were made of concrete with varied water-cement ratio contents from 0.48 to 0.59. The specimens were taken from Diyarbakir-Turkey concrete centers and tested at the structure and material science lab, civil engineering, faculty of engineering from Dicle University.  The UPV measurement and compressive strength tests were carried out at the concrete age of 28 days. Their UPV and compressive strength ranged

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Engineering
Methods for Removing Dyes from Polluted Water; A Review
...Show More Authors

Most of the water pollutants with dyes are leftovers from industries, including textiles, wool and others. There are many ways to remove dyes such as sorption, oxidation, coagulation, filtration, and biodegradation, Chlorination, ozonation, chemical precipitation, adsorption, electrochemical processes, membrane approaches, and biological treatment are among the most widely used technologies for removing colors from wastewater. Dyes are divided into two types: natural dyes and synthetic dyes.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 02 2017
Journal Name
Kufa Journal Of Engineering
COMPRESSIVE STRENGTH OF CONCRETE CONTAINING WATER ABSORPTION POLYMER BALLS (WAPB)
...Show More Authors

Water absorbent polymers (WAP) are new component in producing building materials. They provide internal curing which reduces autogenous cracking, eliminates autogenous shrinkage, mortar strength increased, enhance early age strength to withstand strain, improve the durability, introduce higher early age compressive strength, have higher performance and reduce the effect of insufficient external curing. This research used different percent of polymer balls to choose the percent that provides good development in compressive strength with time for both water and air curing. The water absorption polymer balls in this research have the ability to absorb water and after usage in concrete they spill out the water (internal curing) and shri

... Show More
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
EFFECT OF SALINE WATER AND POTASH FERTILIZER ON PROLINE CONTENT AND WATER POTENTAL IN PISUM SATIVUM L. (VAR.SENADOR CAMBADOS)
...Show More Authors

Filed experiment was conducted to test the effect of saline water and potassium fertilizers rate on proline and water potential of Pisum sativum L. (Var.Senador Cambados ) leaves . Treatments of the experiment included two levels of water salinity( 2, 7 dSm-1) as a main plot and fertilizer rates as a sub plot. Results indicated that irrigation of plant with saline water 7 dSm-1 and fertilization 150 kg/donum increased proline accumulation and water potential 0.31 mmol/g,-17.00 bar at 9 AM morning and 0.62 mmol/g , -21.00 bar at 3 PM afternoon ,Irrigating plant with a 2 dSm-1 and fertilization 300 kg/donum decreased proline accumulation and water potential of leaves 0.22 mmol/g, -16.00 bar at 9 A

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Pollution threatens water quality in the Central Marshes of Southern Iraq
...Show More Authors

Water pollution is an issue that can be exacerbated by drought as increased concentrations of unwanted substances are a consequence of lower water levels. Polluted water that flows into natural marshlands leads to the deposition of pollutants in the interior of the marsh. Here we present evidence that the interior of the Central Marsh (CM) in southern Iraq suffers from higher levels of pollution than areas closer to the source of water entering the marsh (the Euphrates River). A 1.7m embankment that halts the flow of the Euphrates is only infrequently breached and so the CM is effectively the terminal destination of the waters (and their associated pollutants and agricultural waste) flowing from the West of Iraq.

A range of water

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Oct 01 2008
Journal Name
Journal Of Engineering
WATER QUALITY INDICES FOR TIGRIS RIVER IN BAGHDAD CITY
...Show More Authors

Due to the deterioration of water quality within the last few years because of the increase of water consumption and the waste water production and disposal into the river The water quality in both surface and ground water resources was negatively affected .The concept of water quality index is used as a tool for water quality classification in Tigris River within Baghdad City .Twenty two parameters of pollution were selected to measure the water quality indices of Tigris river within Baghdad city .Those parameters were measured during (2000-2004)as average monthly values ,three water treatment plants were selected out of the eight water treatment plants that exist along the river.Al Kharkh water treatment plant to reflect the water quality

... Show More
View Publication
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Treatment of Al-Muthanna Petroleum Refinery Wastewater by Electrocoagulation Using a Tubular batch Electrochemical Reactor
...Show More Authors
Abstract<p>An electrocoagulation process has been used to eliminate the chemical oxygen demand (COD) from wastewaters discharged from the Al-Muthanna petroleum refinery plant. In this process, a circular aluminum bar was used as a sacrificial anode, and hallow cylinder made from stainless steel was used as a cathode in a tubular batch electrochemical Reactor. Impacts of the operating factors like current density (5-25mAcm<sup>-2</sup>), NaCl addition at concentrations (0-2g/l), and pH at values (3-11) on the COD removal efficiency were studied.</p><p>Results revealed that the increase in current density increases the COD removal efficiency, whereas an increase</p> ... Show More
View Publication
Scopus (10)
Crossref (4)
Scopus Crossref
Publication Date
Wed Jul 10 2019
Journal Name
Journal Of Basic Education
Viscometric and Activation energy study of PEG 6000 in water , and solution of DMSO with water at 298.15K, 308.15, 318
...Show More Authors

Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY THE CONTAMINATION OF WATER BOTTLES WITH SOME CHEMICALS DUE TO HEAT EXPOSURE: STUDY THE CONTAMINATION OF WATER BOTTLES WITH SOME CHEMICALS DUE TO HEAT EXPOSURE
...Show More Authors

The transfer of chemical pollutants from bottled water into water due to heat, sunlight and poor storage is one of the most serious threats to human health around the world, the objective of this study was to estimate the pH value and the transport of heavy metals from plastic bottles to water, for this purpose, 30 bottles of water for 10 local brands were collected and divided into three groups, the first was left at room temperature 25°C, The second was placed in a heat oven at 25°C and the third in another oven at 50°C for two weeks. The results showed significant differences at (P<0.05) between water samples, pH value and concentrations of heavy metals (Sb, Pb, Ni, Cu, Cr, Cd and Fe) we

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Design Criteria of an Activated Carbon Bed for Dechlorination of Water
...Show More Authors

Granular carbon can be used after conventional filtration of suspended matter or, as a combination of filtration - adsorption medium. The choice of equipment depends on the severity of the organic removal problem, the availability of existing equipment, and the desired improvement of adsorption condition.
Design calculations on dechlorination by granular - carbon filters considering the effects of flow rate, pH , contact time, head loss and bed expansion in backwashing , particle size, and physical characteristics were considered assuming the absence of bacteria or any organic interface .

View Publication Preview PDF