Shade in house gardens is one of the problems that hinder the growth of lawn and its distribution in the soil, where the types of lawns differ in their durability and adaptation to shade. The research aims to know the resistance of some species of lawn plants to shade and to know the appropriate fertilization procedures that can be followed to reduce the negative effects. The study was conducted in the Amiriya district of Baghdad in a house garden. Three varieties of lawn plants Bermuda, Gazon, and Trifoglio were planted. Five fertilization treatments (contained N and P elements) and the control were used. The sunlight density with the temperature of the study field locations were estimated using the AMT-300 and the vegetation coverage percentage was measured by the Conape program. The results showed a significant difference in the coverage percentage and its area of Bermuda compared with Gazon and Trifoglio, where the average coverage percentage at the end of period of 97.4%, due to the appropriate temperature and its ability to extending rhizomes. The treatment (Dap + Urea + Humic DUH) had a higher coverage rate with a significant difference from other treatments. The results showed a significant increase in the available P in the soil (101 - 146%) and the higher increase rate was in the DU treatment with a slight decrease in available N in the control and DUH treatment. According to the results, humic acid had a role in maintaining the availability of the nutrient and improving its absorption by the plant. The sunlight density level in the house garden is more suitable for Trifoglio and Gazon, thus the two classes could be inserted into mixtures cultivated after the growth of Bermuda in periods of cold weather.
Abstract Background: The hip joint and lumbar spine are both anatomically and functionally closely related as had shown by many authors. So the abnormality in one area can affect the other e.g. hip joint osteoarthritis can cause lumbar sagittal malalignment and backache. Objectives: is to see if there is significant improvement in backache after total hip replacement? And which degree of backache improvement is associated with significant changes in lumbar lordosis? Methods and patients: a prospective open trial study was performed on 30 patients who had severe hip osteoarthritis and chronic low back pain. Total hip replacement was performed to all patients. Backache and lumbar lordosis were measured by visual analogue scale and Cobb’s a
... Show MoreA filed experiment was carried out at one of the private farms at Al-Suwaira District, Wasit Governorate during the spring season 2021, in order to evaluate the effect of adding Fulyzme plus (biofertilizer) and the foliar application of green tea extract (organic nutrient) on growth and yield of pepper plant cv. California wonder. A factorial experiment (43) was carried out using RCBD Design with three replicates. The Fulyzme plus treatment was applied with four concentrations (0, 10, 20. and 30 g. L-1). The foliar application of green tea extract was applied with three concentrations which were 0, 2 and 4 ml. L-1. Results revealed significant effects of Fulyzme plus at 30 g. L-1 and the foliar application of green tea extract at
... Show MoreIntroduction: COVID-19 vaccine have been indicated to successfully decrease the hazard for symptomatic severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection furthermore associated hospitalisations. Objective: To study the immune response among different types of SARS-CoV-2 vaccines. Methods: This study includes 100 vaccinated individuals (43 Sinopharm, 30 AstraZeneca and 27 Pfizer) with one or two doses from different health centres in Baghdad. During the period from April 2021 to the end of May 2021, SARS-CoV-2 IgG and SARS-CoV-2 IgM levels were detected using AFIAS-6 device depending on FIA (Fluorescence Immunoassay) technique. Results: 93% of the cases were positive for IgG levels, and negative in 7% case
... Show MoreEncasing glass fiber reinforced polymer (GFRP) beam with reinforced concrete (RC) improves stability, prevents buckling of the web, and enhances the fire resistance efficiency. This paper provides experimental and numerical investigations on the flexural performance of RC specimens composite with encased pultruded GFRP I-sections. The effect of using shear studs to improve the composite interaction between the GFRP beam and concrete was explored. Three specimens were tested under three-point loading. The deformations, strains in the GFRP beams, and slippages between the GFRP beams and concrete were recorded. The embedded GFRP beam enhanced the peak loads by 65% and 51% for the composite specimens with and without shear connectors,
... Show MoreThe effective insulation design of the stress grading (SG) system in form-wound stator coils is essential for preventing partial discharges and excessive heat generation under pulse-width modulation excitation. This paper proposes a method to find the optimal insulation design of the SG system aimed at reducing the dielectric and thermal stresses in the machine coil. The non-uniform transmission line model is used to predict the voltage propagation along the overhang, SG, and slot regions considering the variation in the physical properties of the insulation layers. The machine coil parameters for different insulation materials are calculated by using the finite element method. Two optimization algorithms, fmincon and particle swarm optimiz
... Show MoreConcrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show More
