This study aimed to compare the safety and efficacy of laser lithotripsy and pneumatic lithotripsy, the two most commonly used transurethral lithotripsy methods for treating bladder stones in children in Iraq. Between January 2013 and December 2016, 64 children with bladder stones were included in this prospective randomized study, after ethical committee approval and written consent from the children’s parents or caregivers were obtained. Patients were assigned randomly by computer software to two groups treated with either pneumatic cystolithotripsy or laser lithotripsy. A 9 Fr. semirigid ureteroscope was used to pass the lithotripter through and fragment the stone. A catheter of 8–12 Fr. was then introduced and kept in place for 24 h. All children were hospitalized for 24 h, and the catheter was removed the next morning. Outpatient follow-up was maintained for 6–12 months. In terms of operation outcomes and complications, the laser lithotripsy group had a significantly longer duration of operation (74.5 ± 26.6 min vs. 51.5 ± 17.2 min, p = 0.001), whereas the number of patients requiring an extended hospital stay was significantly higher in the pneumatic lithotripsy group (48.5% vs. 16.1%, p = 0.006). Moreover, pneumatic lithotripsy was associated with a significantly greater risk of having at least one adverse effect (64% greater than that in the laser group). Stone clearance rates did not significantly differ between treatment groups. In conclusion, both pneumatic and laser lithotripters can be used to treat children with bladder stones with high efficacy and safety.
The relation between anemia and inflammatory immune response has lately had much attention. This research was conducted from October 2018 until April 2019, including (110) children below 12 years from both gender in some Hospitals, Primary Health care centers, Public Primary Schools and Kindergarten in Baghdad, Iraq. The objective of this study is to determine the possible correlation between iron deficiency anemia and inflammatory immune response among children infected with Entamoeba histolytica or Giardia lamblia. Blood samples were taken from all groups to measure hemoglobin level, serum iron, total iron binding capacity (TIBC), mean corpuscular volume (MCV), and mean corpuscular hemoglobin concentration
... Show MoreSewage sludge samples were collected from Al-rasafa and Al-karkh refinement stations which represent the main stations of Baghdad city. Samples were collected from all treatment stages: before, after, and during refinement processes. The High Purity Germanium Coaxial Detector system with energy resolution 1.8 keV for energy line 1333 keV of Co – 60 radioactive sources was used to measure radioactivity from both natural and artificial sources. GENIE – 2000 analysis the results statistically and qualitatively. The results showed that all sewage sludge samples exhibited natural radioactive level and sometimes less than the international regular standards, but Al–Karkh station showed increment in radioactive levels than Al– Rasa
... Show MoreBackground: Bloody diarrhea plays a major role in
morbidity and mortality especially in developing
countries, it is usually a sign of invasive enteric
infection, there is a thought that amoebic dysentery is
more common than bacillary dysentery in Iraq, and
from 1989 to 1997 amoebic dysentery increase from
20000to 550000 patients.
Objectives: This study aims to:
1. Outline the incidence of various infectious causes of
bloody diarrhea in Erbil district.
2. Assess the effect of multiple factors like age, sex,
source of water supply, etc... On the incidence of
amebic and bacillary dysentery.
3. To provide baseline data for making strategic plan to
reduce the diarrhoeal mortality and morbidity.
Met
In this research, the methods of Kernel estimator (nonparametric density estimator) were relied upon in estimating the two-response logistic regression, where the comparison was used between the method of Nadaraya-Watson and the method of Local Scoring algorithm, and optimal Smoothing parameter λ was estimated by the methods of Cross-validation and generalized Cross-validation, bandwidth optimal λ has a clear effect in the estimation process. It also has a key role in smoothing the curve as it approaches the real curve, and the goal of using the Kernel estimator is to modify the observations so that we can obtain estimators with characteristics close to the properties of real parameters, and based on medical data for patients with chro
... Show MoreThis article aims to explore the importance of estimating the a semiparametric regression function ,where we suggest a new estimator beside the other combined estimators and then we make a comparison among them by using simulation technique . Through the simulation results we find that the suggest estimator is the best with the first and second models ,wherealse for the third model we find Burman and Chaudhuri (B&C) is best.
In this paper was discussed the process of compounding two distributions using new compounding procedure which is connect a number of life time distributions ( continuous distribution ) where is the number of these distributions represent random variable distributed according to one of the discrete random distributions . Based on this procedure have been compounding zero – truncated poisson distribution with weibell distribution to produce new life time distribution having three parameter , Advantage of that failure rate function having many cases ( increasing , dicreasing , unimodal , bathtube) , and study the resulting distribution properties such as : expectation , variance , comulative function , reliability function and fa
... Show MoreA metal mandrel was designed for manufacturing the cathodes of high power electron tube ( Tetrode ) used in broadcasting transmitting tubes type TH558 and CQS200.The cathodes were manufactured in the present work from thoriated tungsten wires ( 2? ThO2- W) with different diameters .These cathodes were carbonized in sequences of processes to determine the carbonization parameters (temperature, pressure, time, current and voltage).Then the carbonized cathodes dimension were accurately measured to determine the deviation due to the high temperature distortion effect at about 1800°C .the distorted cathodes due to the carbonization process was treated when it was subjected inside the vacuum chamber and heat treated again .The carbonized cat
... Show More