This study introduces a highly sensitive trapezium-shaped PCF based on an SPR refractometric sensor with unique design features. The structure of a sensor was designed and analyzed using COMSOL Multiphysics v5.6 based on Finite Element Method (FEM) with a focus on investigating the influence of various geometric parameters on its performance. The two channels were coated with a metallic gold layer to provide chemical stability, and a thin layer of TiO₂ improved the gold's adhesion to the fiber. The findings indicate that the proposed sensor achieves maximum amplitude and wavelength sensitivities of 1,779 RIU⁻¹ and 30,500 nm/RIU, respectively, with corresponding resolutions of 3.28×10⁻⁶ RIU for analyte RI sensing ranging from 1.30 to 1.42, operating in the visible to near-infrared region with a wavelength range (500 nm-1400 nm). The highly sensitive sensor provides wide potential for RI detection in chemical and biological sensing.
Mouth ulcers are common oral lesions. Although several topical treatments are commercially available, their limited residence time requires frequent application, which remains a significant drawback. This study aimed to develop a novel mucoadhesive, thermosensitive, in situ gel-forming spray for local delivery of betamethasone sodium phosphate, thereby reducing systemic exposure. Formulations were optimized using the design of experiment approach to investigate the effects of thermosensitive polymers (Poloxamer 407 and Poloxamer 188), mucoadhesive polymer (hyaluronic acid), and drug incorporation on gelation temperature and time. The optimized formulation gelled at 33.3 ± 0.7 °C within 14.79 ± 1.87 s and showed a spray angle of 4
... Show MoreZinc oxide (ZnO) nanostructures were synthesized through the hydrothermal method at various conditions growth times (6,7 and 8 hrs.) and a growth temperature (70, 90, and 100 ºC). The prepared ZnO nanostructure samples were described using scanning electron microscopy (SEM) and X-ray diffractometer to distinguish their surface morphologies and crystal structures. The ZnO samples were confirmed to have the same crystal type, with different densities and dimensions (diameter and length). The obtained ZnO nanostructures were used to manufacture gas sensors for NO2 gas detection. Sensing characteristics for the fabricated sensor to NO2 gas were examined at different operating temperatures (180, 200, 220, and 240) ºC with a low gas concentrati
... Show MoreThis study attempts to provide an approach analysis for the news, depending on the bases and principles which conceptuality semiotic researchers of this field first of them «A. J. Gremas» for the theory of «narrative discourse analysis», to more clarify we tried to apply it on a published press- news, to concludes the most important steps and methods that are necessary to follows gain more understanding of the press- news.
Thin films ZrO2: MgO nanostructure have been synthesized by a radio frequency magnetron plasma sputtering technique at different ratios of MgO (0,6, 8 and 10)% percentage to be used as the gas sensor for nitrogen dioxide NO2. The samples were investigated by X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) and sensing properties were also investigated. The average particle size of all prepared samples was found lower than 33.22nm and the structure was a monoclinic phase. The distribution of grain size was found lower than36.3 nm and uninformed particles on the surface. Finally, the data of sensing properties have been discussed, where the
... Show MoreIn this research, a sensor for chemical solutions was designed and formed using optical fiber-based on a surface Plasmon resonance technology. A single-mode optical fiber with three different diameters (25, 45 and 65) µm was used, respectively. The second layer of the low refractive fiber was replaced by gold, which was electrically deposited at 40 µm thickness. For each of the three types of optical fiber, different saline concentrations (different index of refraction) were used to evaluate the performance of the refractive index sensor (chemical sensor) by measuring its sensitivity and resolutions. The highest values we could get for these two parameters were 240mm/RIU, and 6*10-5 RIU respectively, when the diameter of a
... Show MoreBackground: A worldwide health epidemic, type 2 diabetes mellitus was significantly influenced by chronic inflammation, which led to increased insulin resistance (IR). The most widely practiced form of therapy used to control musculoskeletal pain in people with diabetes is non-steroidal anti-inflammatory drugs (NSAIDs), which provide their action by inhibiting cyclooxygenase enzyme (COX). COX1, COX2, and COX3 are distinct isoforms of the cyclooxygenase enzyme. The potential anti-inflammatory benefits of cyclooxygenase-2 (COX-2) inhibitors, both selective and non-selective, have been investigated concerning the management of type 2 diabetes patients. Objective: the purpose of this research is to explore the impact of highly selective
... Show MoreDirectional control valves are designed to control direction of flow, while actuators maintain required speeds and precise positions. Magnetorheological (MR) fluid is a controllable fluid. Utilizing the MR fluid properties, direct interface between magnetic fields and fluid power is possible, without the need for mechanical moving parts like spools. This study proposes a design of a four-way three-position MR directional control valve, presents a method of building, and explains the working principle of the valve. An analysis of the design and finite elements using finite element method of magnetism (FEMM) software was performed on each valve. The magnetic circuit of the MR valve was analyzed and the performance was simulated. The
... Show MoreThe current study is unique in its emphasis on investigating design operation and concept from multiple scientific perspectives: including invention, technique, and design components. This research tends to study the methodology and creation of design process in a holistic manner so that the readers may grasp their characteristics and properties down to its minute epistemological detail. The investigation of the design concept is where the real groundwork and pressing need for the study begin. Creation and methodology are two primary concepts in relation to design these relationships can be formed in any design because of the various forces that act upon it. The primordial objective of this study is to evaluate the relationship betw
... Show MoreThis study focuses on synthesizing Niobium pentoxide (Nb2O5) thin films on silicon wafers and quartz substrates using DC reactive magnetron sputtering for NO2 gas sensors. The films undergo annealing in ambient air at 800 °C for 1 hr. Various characterization techniques, including X-ray diffraction (XRD), atomic force microscopy (AFM), energy-dispersive X-ray spectroscopy (EDS), Hall effect measurements, and sensitivity measurements, are employed to evaluate the structural, morphological, electrical, and sensing properties of the Nb2O5 thin films. XRD analysis confirms the polycrystalline nature and hexagonal crystal structure of Nb2O5. The optical band gap values of the Nb2O5 thin films demonstrate a decrease from 4.74 to 3.73 eV
... Show More