Preferred Language
Articles
/
ABh_qZYBVTCNdQwCGob-
The possibility of Using the Low-Cost External Antenna with Smartphone for Accurate Surveying Applications by RTX Technology
...Show More Authors
Abstract<p>Real Time Extended (RTX) technology works to take advantage of real-time data comes from the global network of tracking stations together with inventor locating and compression algorithms to calculate and relaying the orbit of satellite, satellite atomic clock, and any other systems corrections to the receivers, which lead to real-time correction with high accuracy. These corrections will be transferred to the receiver antenna by satellite (where coverage is available) and by IP (Internet Protocol) for the rest of world to provide the accurate location on the screen of smartphone or tablet by using specific software. The purpose of this study was to assess the accuracy of Global Navigation Satellite System (GNSS) low-cost external antenna and possibility for using it with a smartphone to measure the points in Real Time Kinematic (RTK) and (RTX) modes, obtaining the same accuracy by using high-cost (GNSS) receiver with same modes. The assessment has applied through comparing the control points measured in static mode (3 to 5 hours) and corrected by Online Positioning User Service (OPUS) web-based processing software with same control points measured in RTX mode by GNSS low-cost external antenna (5 minutes). The results of an assessment were obtained horizontal and vertical location error in real time, by receiver getting the RTX correction data over the satellite link were RMS (east 41cm, north 35 cm, elevation 94 cm), that means it’s more suitable for automotive, agriculture, and forestry application, As for the RTK mode, the comparison of the differences in RTK mode between the two antennas were RMS (north 5 cm, east 6 cm, elevation 10). This result indicates that the GNSS low-cost external antenna might be very useful in accurate surveying application.</p>
Scopus Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Practical Study for the Properties of Hueckel Edge Detection Operator
...Show More Authors

View Publication
Crossref (4)
Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
The role of prophylactic antibiotics in nasal packing for epistaxis
...Show More Authors

Background: This study is to evaluate the necessity of prescribing prophylactic antibiotics for nasal packing in spontaneous epistaxis. There are few published papers of infective complications in such patients.

Methods: This prospective study analysed 149 consecutive patients admitted to AL-Kindy teaching hospital with spontaneous, epistaxis, who underwent nasal packing  over 2 years period . in the first  year, 78 patients received prophylactic antibiotics , In the second  year 71 patients were not given prophylatic antibiotics.  Exclusion criteria included antibiotics prescribed for unrelated  pathology and post-operative epistaxis. Signs and symptoms of acute otitis m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Travel Medicine And Infectious Disease
Incidence of the COVID-19 in Iraq – Implications for travellers
...Show More Authors

View Publication
Scopus (19)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Electronic diagnostics system for the analysis of laser beam profile
...Show More Authors

In this work the analysis of laser beam profile system ,using a two dimensional CCD (Charge Coupled Device) arrays, is established. The system is capable of producing video graphics that give a two dimensional image of laser beam. The video graphics system creates color distribution that represent the intensity distribution of the laser beam or the energy profile of the beam. The software used is capable of analyzing and displaying the profile in four different methods that is , color code intensity contouring , intensity shareholding, intensity cross section along two dimension x-y, and three dimensional plot of the beam intensity given in the same display.

View Publication Preview PDF
Publication Date
Sun Jun 11 2017
Journal Name
Al-academy
Ceramic Art and Urban Planning for the city of Baghdad
...Show More Authors

Ceramic art associated with urban growth in the cities, it overlapped with architectural construction, the increasing of population, urban growth, knowledge, and civilization was considered ceramic arts as an important aesthetically architecturally complement in the cities, including those in the squares and architectural institutions in the city of Baghdad .the title (Ceramic Art and Urban Planning in the City of Baghdad) the problem was its wonders : 1- Does ceramic monuments suited their locations in the city of Baghdad with the architectural planning urban of the city.2- Does the recipient interacted with these monuments and the reasons of their existence. Then the aim: knowing the relationship of the ceramic monuments with the urban

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Lecture Notes Of The Institute For Computer Sciences, Social Informatics And Telecommunications Engineering
Sensor Data Classification for the Indication of Lameness in Sheep
...Show More Authors

View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Spectrofluorimetric method for the determination of glibenclamide in pharmaceutical formulations
...Show More Authors

A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 03 2016
Journal Name
Technology Reports Of Kansai University
Some statistical results for solution type of the Inequalities system
...Show More Authors

Publication Date
Mon Dec 24 2018
Journal Name
Civil Engineering Journal
Artificial Neural Network Model for the Prediction of Groundwater Quality
...Show More Authors

The present article delves into the examination of groundwater quality, based on WQI, for drinking purposes in Baghdad City. Further, for carrying out the investigation, the data was collected from the Ministry of Water Resources of Baghdad, which represents water samples drawn from 114 wells in Al-Karkh and Al-Rusafa sides of Baghdad city. With the aim of further determining WQI, four water parameters such as (i) pH, (ii) Chloride (Cl), (iii) Sulfate (SO4), and (iv) Total dissolved solids (TDS), were taken into consideration. According to the computed WQI, the distribution of the groundwater samples, with respect to their quality classes such as excellent, good, poor, very poor and unfit for human drinking purpose, was found to be

... Show More
View Publication
Crossref (30)
Clarivate Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Applied Spectroscopy
SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF METOCLOPRAMIDE IN PHARMACEUTICAL FORMS
...Show More Authors

A UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b

... Show More
Scopus (11)
Scopus