Preferred Language
Articles
/
ABeNWpMBVTCNdQwCjNKL
Assessment the Complications of Caesarean Section among Women’s attending AL -Diwaniyah Maternity and Pediatric Hospital/Iraq
...Show More Authors

Aims: This study aimed to assess complications of caesarean section among pregnant women attending AL Diwaniyah Maternity and Pediatric Hospital; and find out relationship between complications of caesarean section and socio-demographic data of women. Methods: A descriptive cross-sectional study design is conducted for the period of December 26th 2020 to June 1st 2021. The validity of the questionnaire is determine through a panel of experts and reliability was achieved through a pilot study. By a purposive sample is selected among pregnant women who undergo caesarean section, data was collected through the use of questionnaire and interview techniques; and analyzed through the descriptive and inferential statistic. Results: Findings indicate participants age, the mean age was 29±7.723, the age 20-29 years old (n=217; 43.4%), a not read and write (n=149; 29.8%), more than half of studied participants were housewife (n=339; 67.8%), most of study participants were overweight (n=248; 49.6%). Findings showed that the factors associated with caesarean section were post-partum hemorrhage, prolonged operation wound infection and postpartum infection among studied sample. Regarding fetal complication ,Low Apgar score(n=348;69.6%),respiratory distress syndrome (n=352;70.4%), and perinatal asphyxia(n=468;93.6%), among studied sample. The education and BMI have been significant relationship with their associated factors of caesarean section at p-value <0.05.

Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 19 2020
Journal Name
Indonesian Journal Of Chemistry
Determination of Eugenol in Personal-Care Products by Dispersive Liquid-Liquid Microextraction Followed by Spectrophotometry Using &lt;i&gt;p&lt;/i&gt;-Amino-&lt;i&gt;N,N&lt;/i&gt;-dimethylaniline as a Derivatizing Agent
...Show More Authors

Two simple methods for the determination of eugenol were developed. The first depends on the oxidative coupling of eugenol with p-amino-N,N-dimethylaniline (PADA) in the presence of K3[Fe(CN)6]. A linear regression calibration plot for eugenol was constructed at 600 nm, within a concentration range of 0.25-2.50 μg.mL–1 and a correlation coefficient (r) value of 0.9988. The limits of detection (LOD) and quantitation (LOQ) were 0.086 and 0.284 μg.mL–1, respectively. The second method is based on the dispersive liquid-liquid microextraction of the derivatized oxidative coupling product of eugenol with PADA. Under the optimized extraction procedure, the extracted colored product was determined spectrophotometrically at 618 nm. A l

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (6)