Objectives: Semen analysis is the cornerstone for the valuation of the male partner in the infertile couples. This test has been standardized throughout the world through the World Health Organization (WHO) since the1970s by producing, editing, updating, and disseminating a semen analysis manual and guidelines. A retrospective study to give an insight about male infertility. Methods: This retrospective study assessed the semen findings of 1000 men evaluated at the Department of Urology, Al-Kindy Teaching Hospital in Baghdad-Iraq between January 2016 and May 2019. Semen analysis were done for them. Results: According to WHO standard for semen normality, 1000 samples that were analyzed, normospermia was shown in 835 (83.5%)males (95% CI=0.811-0.857) and 12% had oligospermia and the rest 4.5% was azospermia. The normospermic samples had significantly higher levels regarding the following parameters: count per ml (51.30±1.24) (P= 0.001), volume(3.34±2.31)(P=0.0001), pus cell (8.04±1.02)(P=0.0001), motility (22.81±5.8)(P=0.0001), abnormal motility (22.81±5.8)(P=0.0001) and normal (V)(P=0.0001)or abnormal morphology (25.86 ±12.4)(P=0.0002) when compared with oligospermia. Conclusions: Semen analysis is the keystone of infertile couple. Semen parameters like sperm concentration, motility and morphology, are indicators for male reproductive function. Sperm concentration is declining and there is a significant association between sperm concentration and sperm parameters.
Ficus (FIC) leaf extract used as corrosion inhibitor for carbon steel alloy (C.S) in two corrosive environments (saline and acidic) with four concentrations (1, 2, 3 and 4 ppm) at varied temperature range between (298-328 K) using electrochemical polarization measurements. The importance of this work focused on the use the green chemistry that is far from the chemical materials effect. The results of polarization presented the FIC inhibitor consider a mixed type (anodic and cathodic) inhibitor. Tafel curve used to evaluate the corrosion inhibition activity. In a saline medium, the best inhibitor efficiency reaches to (87%) in 2 ppm and IE% reach to (99%) for HCl medium inhibited by 1ppm. Langmuir isotherm obeys the study by thermodynamic pa
... Show MoreThe provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were
... Show MoreThe provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were
... Show MoreIn this study, ultraviolet (UV), ozone techniques with hydrogen peroxide oxidant were used to treat the wastewater which is produced from South Baghdad Power Station using lab-scale system. From UV-H2O2 experiments, it was shown that the optimum exposure time was 80 min. At this time, the highest removal percentages of oil, COD, and TOC were 84.69 %, 56.33 % and 50 % respectively. Effect of pH on the contaminants removing was studied in the range of (2-12). The best oil, COD, and TOC removal percentages (69.38 %, 70 % and 52 %) using H2O2/UV were at pH=12. H2O2/ozone experiments exhibited better performance compared to
... Show MoreIn this study; a three-dimensional model was created to simulate groundwater in Al-Haydariyah area of the governorate of Al-Najaf. A solid model was created to utilize the cross sections of 25 boreholes in the research region, and it was made out of two layers: sand and clay. The steady-state calibration was employed in six observation wells to calibrate the model and establish the hydraulic conductivity, which was 17.49 m/d for sand and 1.042 m/d for clay, with a recharge rate of 0.00007 m/day. The wells in the research region were reallocated with a distance of 1500 m between each well, resulting in 140 wells evenly distributed throughout the study area and with a discharge of 5 l/s, and the scenarios were run for 1000
... Show More