Objectives: Semen analysis is the cornerstone for the valuation of the male partner in the infertile couples. This test has been standardized throughout the world through the World Health Organization (WHO) since the1970s by producing, editing, updating, and disseminating a semen analysis manual and guidelines. A retrospective study to give an insight about male infertility. Methods: This retrospective study assessed the semen findings of 1000 men evaluated at the Department of Urology, Al-Kindy Teaching Hospital in Baghdad-Iraq between January 2016 and May 2019. Semen analysis were done for them. Results: According to WHO standard for semen normality, 1000 samples that were analyzed, normospermia was shown in 835 (83.5%)males (95% CI=0.811-0.857) and 12% had oligospermia and the rest 4.5% was azospermia. The normospermic samples had significantly higher levels regarding the following parameters: count per ml (51.30±1.24) (P= 0.001), volume(3.34±2.31)(P=0.0001), pus cell (8.04±1.02)(P=0.0001), motility (22.81±5.8)(P=0.0001), abnormal motility (22.81±5.8)(P=0.0001) and normal (V)(P=0.0001)or abnormal morphology (25.86 ±12.4)(P=0.0002) when compared with oligospermia. Conclusions: Semen analysis is the keystone of infertile couple. Semen parameters like sperm concentration, motility and morphology, are indicators for male reproductive function. Sperm concentration is declining and there is a significant association between sperm concentration and sperm parameters.
Psoriasis is a long-lasting autoimmune disease that is characterized by swollen skin patches. Normally, these skin patches are dark, swollen, itchy and scaly. The single application of the innate TLR7/8 ligand Imiquimod (IMQ) in mice easily induces a dermatitis that closely resembles human psoriasis, critically dependent on the axis of IL-23/IL-17. Artemisia dracunculus prepared as an ointment and has been used topically to mice before imiquimod application. The results of the current study showed that A. dracunculus ointment can significantly reduce psoriasis area and severity index in (A. dracunculus ointment + imiquimod group as compared with both control group and (vehicle ointment + imiquimod) group.
In this paper, the Monte Carlo N-Particle extended computer code (MCNP) were used to design a model of the European Sodium-cooled Fast Reactor. The multiplication factor, conversion factor, delayed neutrons fraction, doppler constant, control rod worth, sodium void worth, masses for major heavy nuclei, radial and axial power distribution at high burnup are studied. The results show that the reactor breeds fissile isotopes with a conversion ratio of 0.994 at fuel burnup 70 (GWd/T), and minor actinides are buildup inside the reactor core. The study aims to check the efficiency of the model on the calculation of the neutronic parameters of the core at high burnup.
New series of metal ions complexes have been prepared from the new ligand 1,5- Dimethyl-4- (5-oxohexan-2- ylideneamino) -2-phenyl- 1H-pyrazol-3 (2H)-one derived from 2,5-hexandione and 4-aminophenazone. Then, its V(IV), Ni(II), Cu(II), Pd(II), Re(V) and Pt(IV) complexes prepared. The compounds have been characterized by FT-IR, UV-Vis, mass and 1H and 13C-NMR spectra, TGA curve, magnetic moment, elemental microanalyses (C.H.N.O.), chloride containing, Atomic absorption and molar conductance. Hyper Chem-8 program has been used to predict structural geometries of compounds in gas phase, the heat of formation, (binding, total and electronic energy) and dipole moment at 298 K.
Fuzzy logic is used to solve the load flow and contingency analysis problems, so decreasing computing time and its the best selection instead of the traditional methods. The proposed method is very accurate with outstanding computation time, which made the fuzzy load flow (FLF) suitable for real time application for small- as well as large-scale power systems. In addition that, the FLF efficiently able to solve load flow problem of ill-conditioned power systems and contingency analysis. The FLF method using Gaussian membership function requires less number of iterations and less computing time than that required in the FLF method using triangular membership function. Using sparsity technique for the input Ybus sparse matrix data gi
... Show MoreFind the impediments Activity vital and important, but focuses a bancassurance activity, diagnosis and its impact on the financial ratios indicators for insurance companies. The researcher has adopted in his research on several financial ratios used to analyze the financial performance of a (relative profitability, liquidity ratio and the ratio of solvency) of the company Iraqi insurance for a period of one year (2009) to a year (2015), based on the annual reports and financial statements (balance sheet revealed income), financial statements for insurance premiums for banks research sample of this research has addressed several topics of theoretical and practical body through which the researcher obstacles to banking and insurance experi
... Show MoreThis paper presents a numerical simulation for the combined effect of surface roughness and non-Newtonian behavior of the lubricant on the performance of misaligned journal bearing. The modified Reynolds equation to include the effect of non-Newtonian lubricant and bearing surface roughness has been formulated. The model accounts for the lubricant viscosity dependence on temperature and shear rate. In order to make a complete thermo-hydrodynamic analysis (THD) of rough surface misaligned journal bearing lubricated with non-Newtonian lubricant, the modified Reynolds equation coupled with the energy, heat conduction equations, the equation related the viscosity and temperature with appropriate boundary conditions have been solved simultane
... Show MoreIn this study, the electro-hydraulic servo system for speed control of fixed displacement hydraulic motor using proportional valve and (PID) controller is investigated theoretically ,experimentally and simulation . The theoretical part includes the derivation of the nonlinear mathematical model equation of (valve – motor ) combination system and the derivation of the transfer function for the complete hydraulic system , the stability test of the system during the operation through the transfer function using MATLAB package
V7.1 have been done. An experimental part includes design and built hydraulic test rig and simple PID controller .The best PID gains have been calculated experimentally and simulation, speed control performance te