Preferred Language
Articles
/
A4ZSsoYBIXToZYAL6rFD
Dynamic monitoring of saturated stiff clay soil foundation structure by falling weight deflectometer system under impact loads sensors effect
...Show More Authors

Experiments research is done to determine how saturated stiff clayey soil responds to a single impulsive load. Models made of saturated, stiff clay were investigated. To supply the single pulse energy, various falling weights from various heights were tested using the falling weight deflectometer (FWD). Dynamic effects can range from the major failure of a sensitive sensor or system to the apparent destruction of structures. This study examines the response of saturated stiff clay soil to a single impulsive load (vertical displacement at the soil surface below and beside the bearing plates). Such reactions consist of displacements, velocities, and accelerations caused by the impact occurring at the surface depth induced by the impact loads and then recorded using the multi-recorder sensors. Using different factors, including soil surface, and the applied energies, the behavior of saturated stiff clay soil was investigated. Under the same impact loads (5 Kg) for both dropping elevations (250.00 mm and 500.00 mm), at soil surface level the average percent of change in the maximum impact forces generated in the contact surface increased by 41%, which resulted in a reduction of 34% in the maximum displacement reaction of the clay soil model.

Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Plasma Medicine
Effect of Cold Atmospheric Plasma on Osteoporosis by FE-DBD System
...Show More Authors

The work demonstrates the effect of cold atmospheric plasma (CAP) on adult female rats suffering from osteoporosis, the used plasma was generated by a floating electrode-dielectric barrier discharge system with an electrode diameter of 3 cm. The output power was from (12-20) watts. The effect of non-thermal plasma was observed on rats with various exposure times of 20, 30, and 40 sec. It was noted that the blood calcium percentage of animals exposed to cold plasma increased, as well as an increase in the level of vitamin D3 at the same time, it is noted that there is no effect on parathyroid hormone level. For the thyroid gland, it is noticed an increase in the level of T3, and T4 hormones in the blood during the period of induction for

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 02 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Identification of microflora associated with dust falling on Karbala province and seasonal distribution
...Show More Authors

Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Proceedings Of The Institution Of Civil Engineers - Structures And Buildings
Effect of soil saturation on load transfer in a pile excited by pure vertical vibration
...Show More Authors

A comparison between the resistance capacity of a single pile excited by two opposite rotary machines embedded in dry and saturated sandy soil was considered experimentally. A small-scale physical model was manufactured to accomplish the experimental work in the laboratory. The physical model consists of: two small motors supplied with eccentric mass 0·012 kg and eccentric distance 20 mm representing the two opposite rotary machines, an aluminum shaft with 20 mm in diameter as the pile, and a steel plate with dimensions of (160 × 160 × 20 mm) as a pile cap. The experimental work was achieved taking the following parameters into consideration, pile embedment depth ratio (L/d; length to diameter) and operating freq

... Show More
View Publication
Scopus (14)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
E3s Web Of Conferences
Experimental Investigation of Bearing Capacity of Screw Piles and Excess Porewater Pressure in Soft Clay under Static Axial Loading
...Show More Authors

In this study, the behavior of screw piles models with continuous helix was studied by conducting laboratory experimental tests on a single screw pile that has several aspect ratios (L/D) under the influence of static axial compression loads. The screw piles were inserted in a soft soil that has a unit weight of 18.72 kN/m3 and moisture content of 30.19%. Also, the soil has a liquid limit of 55% and a plasticity index of 32%. A physical laboratory model was designed to investigate the ultimate compression capacity of the screw pile and measure the generated porewater pressure during the loading process. The bedding soil was prepared according to the field unit weight and moisture content and the failure load was assumed correspondin

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (6)
Scopus Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of Flaring Angle of Transition Structure On the Scouring of outlet structure
...Show More Authors

The transition structure is considered as the most important hydraulic structure controlling the w/s transtion, morever it decrease the scouring of outlet structure.

seven experiment samples for transition structure was used in this research at different angles ( 10° - 90° ).

       It was shown that froud number has a clear effect on the depth of the scouring, morever the high discharge rates cause an increase of the ratio between the length of the scour and its depth.

       In order to select the best flaring angle it was shown that the angle of 40° has the most discharge rate, least structure length and least angle scour depth, with the firmly of t

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Replacement of Line Loads acting on slabs to equivalent uniformly Distributed Loads
...Show More Authors

This study aims to derive a general relation between line loads that acting on two-way slab system and the equivalent uniformly distributed loads. This relation will be so useful to structural designer that are used to working with a uniformly distributed load and enable them to use the traditional methods for analysis of two-way systems (e.g. Direct Design Method). Two types of slab systems, Slab System with Beams and Flat Slab Systems, have been considered in this study to include the effect of aspect ratio and type of slab on the proposed relation. Five aspect ratios, l2/l1 of 0.5, 0.75, 1.0, 1.5 and 2.0, have been considered for both types of two-way systems.
All necessary finite element analyses have been executed with SAFE Soft

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 28 2024
Journal Name
Iraqi Journal Of Agricultural Sciences
COMPARISON OF TWO TYPES OF SENSORS AND THEIR EFFECT ON SPRAY QUALITY PEAR TREES
...Show More Authors

This study was aimed to reduce the amount of the sprayed solution lost during trees spraying.  At the same time, the concentration of the sprayed solution on the target (tree or bush) must be ensured and to find the best combination of treatments. Two factors controls the spraying process: (i) spraying speed (1.2 km/h, 2.4 km/h, 3.6 km/h), and (ii) the type of sensor. The test results showed a significant loss reduction percentage. It reached (6.05%, 5.39% and 2.05%) at the speed (1.2 km/h, 2.4 km/h, 3.6 km/h), respectively. It was noticed that when the speed becomes higher the loss becomes less accordingly. The interaction between the 3.6 km/h speed and the type of Ultrasonic sensor led to a decrease in the percentage of the spray

... Show More
Scopus Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Improvement of Earth Canals Constructed on Gypseous Soil by Soil Cement Mixture
...Show More Authors

The gypseous soil may be one of the problems that face the engineers especially when it used as a foundation for hydraulic structures, roads, and other structures. Gypseous soil is strong soil and has good properties when it is dry, but the problem arises when building hydraulic installations or heavy buildings on this soil after wetting the water to the soil by raising the water table level from any source or from rainfall which leads to dissolve the gypsum content. Cement-stabilized soil has been successfully used as a facing or lining for earth channel, highway embankments and drainage ditches to reduce the risk of erosion and collapsibility of soil. This study is deliberate the treatment of gypseous soil by using a mixture

... Show More
Crossref (10)
Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Improvement of Earth Canals Constructed on Gypseous Soil by Soil Cement Mixture
...Show More Authors

The gypseous soil may be one of the problems that face the engineers especially when it used as a foundation for hydraulic structures, roads, and other structures. Gypseous soil is strong soil and has good properties when it is dry, but the problem arises when building hydraulic installations or heavy buildings on this soil after wetting the water to the soil by raising the water table level from any source or from rainfall which leads to dissolve the gypsum content.

Cement-stabilized soil has been successfully used as a facing or lining for earth channel, highway embankments and drainage ditches to reduce the risk of erosion and collapsibility of soil. This study is deliberate the treatment of gypseous soil by u

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Variable Structure Control Design for a Magnetic Levitation System
...Show More Authors

In this paper the variable structure control theory is utilized to derive a discontinuous controller to the magnetic levitation system. The magnetic levitation system model is considered uncertain, which subjected to the uncertainty in system parameters, also it is open-loop unstable and strongly nonlinear. The proposed variable structure control to magnetic levitation system is proved, and the area of attraction is determined. Additionally, the chattering, which induced due to the discontinuity in control law, is attenuated by using a non-smooth approximate. With this approximation the resulted controller is a continuous variable structure controller with a determined steady state error according to the selected control

... Show More
View Publication Preview PDF
Crossref (1)
Crossref