Fluidization process is widely used by a great assortment of industries worldwide and represents a trillion dollar industry [6]. They are currently used in separation, classification, drying and mixing of particles, chemical reactions and regeneration processes; one of these processes is the mass transfer from an immersed surface to a gas fluidized bed
In the current Airlines Air Traffic Management (ATM), the Air Traffic Control Operators (ATCO), with the Air Traffic Control systems (ATC), operate air traffic paths with a small number of fixed routes. Problems of fixed routes appear such that even when they reduce the chance for conflict, they also produce flight paths plans that do not reduce flight time or fuel usage. In nowadays Airlines are heavily overloaded and anxious to minimize the aircrafts fuel usage costs, increase airplanes, and optimize the paths or the flight routes in order to find the most optimal suitable flight paths. This paper presents a new path planning method that deal with such problem effectively, the idea was to produce flights routes
... Show MoreThe Isolated Combustion and Diluted Expansion (ICADE) internal combustion engine cycle combines the advantages of constant volume combustion of the Otto cycle with the high compression ratio of the Diesel cycle. This work studies the effect of isolated air mass (charge stratification) on the efficiency of the cycle; the analysis shows that the decrease of isolated air mass will increase the efficiency of the cycle and the large dilution air mass will quench all NOx forming reactions and reduce unburned hydrocarbons. Furthermore, the effect of Fuel / Air ratio on the efficiency shows that the increase of Fuel / Air ratio will increase efficiency of the cycle.
This research study experimentally the effect of air flow rate on humidification process
parameters. Experimental data are obtained from air conditioning study unit T110D. Results obtained
from experimental test, calculations and psychometrics software are discussed. The effect of air flow rate
on steam humidification process parameters as a part of air-conditioning processes can be explained
according to obtained results. Results of the steam humidification processes (1,2) with and without
preheating with 5A and 7.5A shows decreasing in dry bulb temperature, humidity ratio, and heat add to
moist air with increasing air flow rate, but humidification load, and total energy of moist air increase with
increasing air flo
In this work, we carried out an experimental study of thedusty
plasma by taking the dust material Fe3O4 with radius of the any grain
0.1μm - 0.5μm. In experiment we use air in the vacuum chamber
system under different low pressure (0.1-1) Torr. The results
illustrated that the present of dust particles in the air plasma did not
effect on Paschen minimum which is 0.5 without dust and with Fe3O4
dusty grains.
The effect of Fe3O4 dust particles on plasma parameters can be
notice in direct current system in glow discharge region. The plasma
parameters which were studied in this work represent plasma
potential, floating potential,electron saturation current, temperatu
The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis
... Show MoreIraq has seen many changes at the social, economic and political levels. This led to cause many shifts in the structure of its society and imposed great challenges reflected in the behavior and awareness of that society in general and youth in particular.
Those changes made the Iraqi society undergoing the transformation of value and culture aspects formed a political awareness that caused cultural and political diversity within the family and society. A greater openness to the outside world caused by the communication revolution, as the world has witnessed during the past two decades, has helped in making that change. Iraq had its share of media and political openness, which were included after the US occupation in 2003. As a re
... Show MoreActual and effective organizational dynamic capabilities in the work environment contribute to a number of factors that contribute to the organization's ability to manage its human talents. Thus, the study sought to identify the level of contribution of organizational dynamic capabilities to human talent management based on their dimensions in the investigated organization by determining the level of relationship and impact between these variables. The presidency of Mosul University was chosen as a field for the current study, and data were collected by adopting the questionnaire form as the main tool for the study. The study used a deliberate sample of (42) administrative leaders in the investigated organization and adopte
... Show MoreThe recognition of the dynamic organizational capabilities in their actual and influential extent in the work environment achieves a set of positive data that can fall under the addition axes, particularly with regard to the organization's ability to manage human talents in them, so the researchers sought to identify the level of contribution of dynamic organizational capabilities in the management of human talents in terms of Keep them away in the research organization by indicating the level of relationship and impact between them. The presidency of Mosul University was chosen as a field for the current study, and data were collected by adopting the questionnaire form as the main tool for the study. The study used a deliberate
... Show MoreThis work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation ra
... Show More