Coffee is the most essential drink today, aside from water, the high consumption of coffee and the byproducts of its soluble industries such as spent coffee grounds can have a negative effect on the environment as a source of toxic organic compounds. Therefore, caffeine removal from the spent coffee ground can be applied as a method to limit the effect of its production on the environment. The aim of this study is to determine the kinetics and thermodynamics parameters and develop models for both processes based on the process parameters by using traditional solid-liquid extraction and Ultrasound-assisted extraction methods. The processes were performed at a temperature range of 25 to 55 °C for traditional and ultrasound baths, and experimental time ranged from 5- 60 min. The results demonstrated that under the above conditions, the extraction process applies to the pseudo-first-order reaction, where the rate constant K value increases with temperature. The transition state parameters were also discussed where these parameters indicated that the system of the process exhibited an activated complex formation state resulting in a thermodynamically unfavorable process, and the thermodynamic parameters at the equilibrium state were also evaluated in terms of the obtained yield percentage. The results also showed that the ultrasound-assisted bath process showed a spontaneous behavior at temperatures of 45 °C and 55 °C with D°G of -1192.9703 and - 2725.25 J/mole. On the other hand, for the traditional method, the extraction process was approaching a spontaneous behavior with the temperature increasing where at 25 °C the D°G value was 10379.944 J and at a temperature of 55 °C it reached 8004.26 J/mole.
Liquid – liquid interface reaction is the method for
preparation nanoparticles (NP'S) which depend on the super
saturation of ions that provide by using the system that consist from
toluene and water, the first one is above the second to obtain
nanoparticles (NP's) CdS at the interface separated between these
two immiscible liquid. The structure properties were characterized by
XRD-diffraction and transmission electron microscopy.
The crystalline size estimate from X-ray diffraction pattern
using Scherer equation to be about 7nm,and by TEM analysis give us
that ananosize is about 5 nm which give a strong comparable with
Bohr radius. Photoluminescence analysis give two emission peak,
the first one around
Etoricoxib (EXB) is a highly selective cox-2 inhibitor which belongs to the non-steroidal anti-inflammatory drug (NSAID). EXB is a class II drug according to the biopharmaceutical classification system (BCS), which possess a very low aqueous solubility in water. In the present study, many trials were made to improve the aqueous solubility and dissolution rate of EXB by solid dispersion technique.
Eighteenth EXB formulas were formulated as a solid dispersion using a variety of hydrophilic polymers (as carriers) including poloxamer 407 (PXM 407), poloxamer 188 (PXM 188) and polyethylene glycol 4000 (PEG 4000) at different drug: polymer ratios (1:1, 1:3 and 1:5). These formulas were prepared by two methods; solvent
... Show MoreA method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav
... Show MoreBackground: The excess mortality associated with
rheumatoid arthritis is largely due to
cardiovascular disease. Rheumatoid arthritis is of
primary importance in atherogenesis. The intimamedia thickness of extracranial carotid arteries is a
measurable index of the presence of
atherosclerosis.
Objective: To assess carotid intima-media
thickness in rheumatoid arthritis by Doppler
ultrasound.
Methods: Fifty two Iraqi patients with rheumatoid
arthritis were studied and compared with another
fifty two, healthy individuals matched for age and
sex as a control group. Full history was taken and
complete clinical examination was done for all
individuals in both groups. Rheumatoid arthritis
diagnosis was
The aim of this research work is to evaluate the use of 980 nm diode laser in clotting the blood
in the bone socket after tooth extraction. The objective is to prevent possible clot dislodgement which is
a defect that may lead to possible infection. A number of rabbits were irradiated using 980nm CW mode
diode laser, 0.86W power output for 9s and 15s exposure time. The irradiated groups were studied
histopathologically in comparison with a control group. Results showed that laser photothermal
coagulation was of benefit in minimizing the possibility of the incidence of postoperative complications.
The formation of the clot reduces the possibility of bleeding and infection.