Aim: The aim of this study is to determine the correlation between levels of certain seminal biochemical parameters and serum reproductive hormones, on the one hand, and sperm function tests, on the other hand, in asthenospermic patients. Patients and Methods: Sixty asthenospermic patients and twenty fertile men as a control group were included in this study. Semen samples were collected to perform seminal fluid analysis. Total protein, cholesterol, calcium, creatine kinase, and fructose were measured in the seminal plasma. Blood samples were collected for hormonal assay of serum reproductive hormones: testosterone, prolactin, luteinizing hormone, and follicle-stimulating hormone. Results: The results revealed a significant positive correlation between the seminal cholesterol level and sperm concentration. A similar correlation was observed between the seminal calcium level and motility characteristics (the percentage of sperm motility and sperm grade activity). A significant negative correlation was found between the seminal fructose level and sperm concentration; in addition, a negative correlation was found between the fructose level and sperm motility characteristics. A significant negative correlation was found between the level of serum prolactin and sperm concentration. Also, a similar negative correlation was found between the level of serum follicle-stimulating hormone and sperm concentration. Conclusions: The evaluation of seminal biochemical parameters and serum reproductive hormones provide useful information for clinical studies in the status of male infertility, especially when these parameters are correlated with sperm function tests.
The issue of penalized regression model has received considerable critical attention to variable selection. It plays an essential role in dealing with high dimensional data. Arctangent denoted by the Atan penalty has been used in both estimation and variable selection as an efficient method recently. However, the Atan penalty is very sensitive to outliers in response to variables or heavy-tailed error distribution. While the least absolute deviation is a good method to get robustness in regression estimation. The specific objective of this research is to propose a robust Atan estimator from combining these two ideas at once. Simulation experiments and real data applications show that the p
... Show MoreThe Sequencing Batch Reactor system (SBR) is a major component of the municipal wastewater biological treatment system and water reclamation that provides high-quality water that could be reused in restricted plants that which require large quantities of water despite the lack of water. The research aims to investigate the performance of a pilot plant SBR unit under real operation conditions that was installed and operated in Al-Rustamiya Wastewater Treatment Plant (WWTP), Baghdad, Iraq. Results showed that the BOD5/COD ratio of the raw wastewater was within the average value at 0.66 emphasizing the organic nature of the influent flow and hence the amenability to biological treatment. The results also ensured that the treatment pro
... Show MoreThe present study focused mainly on the buckling behavior of composite laminated plates subjected to mechanical loads. Mechanical loads are analyzed by experimental analysis, analytical analysis (for laminates without cutouts) and numerical analysis by finite element method (for laminates with and without cutouts) for different type of loads which could be uniform or non-uniform, uniaxial or biaxial. In addition to many design parameters of the laminates such as aspect ratio, thickness ratio, and lamination angle or the parameters of the cutout such as shape, size, position, direction, and radii rounding) which are changed to studytheir effects on the buckling characteristics with various boundary conditions. Levy method of classical lam
... Show MoreOne hundred forty three of Klebsiellapneumoniae isolates had been collected from some hospitals in Baghdad city. The isolates were taken from different clinical specimens.Antimicrobial susceptibility test was carried out towards fifteen antimicrobial agents by using Vitek2 system with Antimicrobial susceptibility test cards. The results of antibiogram showed that the local isolates were possess highly resistance towards most antimicrobial agents under study. The high resistance wastoAmpicillin while the low resistance was to Imipenem.Two methods were used for detection of Extended Spectrum Beta Lactamases (ESBLs) production; first methods by using of Vitek2 system,thesecondmethods by using of polymerase chain reaction (PCR) technique to dis
... Show MoreIn this paper, we calculate and measure the SNR theoretically and experimental for digital full duplex optical communication systems for different ranges in free space, the system consists of transmitter and receiver in each side. The semiconductor laser (pointer) was used as a carrier wave in free space with the specification is 5mW power and 650nm wavelength. The type of optical detector was used a PIN with area 1mm2 and responsively 0.4A/W for this wavelength. The results show a high quality optical communication system for different range from (300-1300)m with different bit rat (60-140)kbit/sec is achieved with best values of the signal to noise ratio (SNR).
The goal of this work is demonstrating, through the gradient observation of a of type linear ( -systems), the possibility for reducing the effect of any disturbances (pollution, radiation, infection, etc.) asymptotically, by a suitable choice of related actuators of these systems. Thus, a class of ( -system) was developed based on finite time ( -system). Furthermore, definitions and some properties of this concept -system and asymptotically gradient controllable system ( -controllable) were stated and studied. More precisely, asymptotically gradient efficient actuators ensuring the weak asymptotically gradient compensation system ( -system) of known or unknown disturbances are examined. Consequently, under convenient hypo
... Show MoreIn this work, the switching nonlinear dynamics of a Fabry-Perot etalon are studied. The method used to complete the solution of the differential equations for the nonlinear medium. The Debye relaxation equations solved numerically to predict the behavior of the cavity for modulated input power. The response of the cavity filled with materials of different response time is depicted. For a material with a response time equal to = 50 ns, the cavity switches after about (100 ns). Notice that there is always a finite time delay before the cavity switches. The switch up time is much longer than the cavity build-up time of the corresponding linear cavity which was found to be of the order of a few round-trip ti
... Show MoreAs one type of heating furnaces, the electric heating furnace (EHF) typically suffers from time delay, non-linearity, time-varying parameters, system uncertainties, and harsh en-vironment of the furnace, which significantly deteriorate the temperature control process of the EHF system. In order to achieve accurate and robust temperature tracking performance, an integration of robust state feedback control (RSFC) and a novel sliding mode-based disturbance observer (SMDO) is proposed in this paper, where modeling errors and external disturbances are lumped as a lumped disturbance. To describe the characteristics of the EHF, by using convection laws, an integrated dynamic model is established and identified as an uncertain nonlinear second ord
... Show More