Preferred Language
Articles
/
9RZceIsBVTCNdQwCa8vw
Robust speaker verification by combining MFCC and entrocy in noisy conditions
...Show More Authors

Automatic speaker recognition may achieve remarkable performance in matched training and test conditions. Conversely, results drop significantly in incompatible noisy conditions. Furthermore, feature extraction significantly affects performance. Mel-frequency cepstral coefficients MFCCs are most commonly used in this field of study. The literature has reported that the conditions for training and testing are highly correlated. Taken together, these facts support strong recommendations for using MFCC features in similar environmental conditions (train/test) for speaker recognition. However, with noise and reverberation present, MFCC performance is not reliable. To address this, we propose a new feature 'entrocy' for accurate and robust speaker recognition, which we mainly employ to support MFCC coefficients in noisy environments. Entrocy is the fourier transform of the entropy, a measure of the fluctuation of the information in sound segments over time. Entrocy features are combined with MFCCs to generate a composite feature set which is tested using the gaussian mixture model (GMM) speaker recognition method. The proposed method shows improved recognition accuracy over a range of signal-to-noise ratios.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today: Proceedings
Solving high sulfate content of sand used in concrete by magnetic water process
...Show More Authors

View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
A study of Irrigation Water Pollution By Some Heavy Metals in Baghdad Governorate
...Show More Authors
Abstract<p>A study of irrigation water was conducted Baghdad city to find out extent of its pollution by some heavy metals (Pb, Cd, Ni, Co, CU, Cr, Zn and Fe). Water samples were collected randomly from different sources (river, well and stream). Results showed that the concentration of studied heavy metals were as follows: Lead between 0.43-11.75 mg L<sup>-1</sup>, Cadmium between 0.01-0.95 mg L<sup>-1</sup>, Nickel between 0.008-0.46 mg L<sup>-1</sup>, Cobalt between Nil - 0.185 mg L<sup>-1</sup>, Copper is between 0.326 - 1.58 mg L<sup>-1</sup>, Chromium is between Nil-0.068 mg L<sup>-1</sup>, Zinc 0.398-1.182 mg L<sup>-1</sup>, as for Iro</p> ... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Engineering
Controlling the Salt Wedge Intrusion in Shatt Al-Arab River by a Barrage
...Show More Authors

Shatt Al-Arab River in Al Basrah, Iraq, has recently recorded massive levels of TDS values (Total Dissolved Solids) in the water as a result of reduced fresh water discharge from sources, causing the river to become salinized due to salt wedge intrusion. Therefore, a block dam in the south reach is required to salt intrusion prevention. The main objective of this research is to simulate the hydraulic impact of a suggested barrage in Ras Al Besha on the Shatt Al-Arab River. The HEC-RAS (5.0.7) model was used to develop a one-dimensional unsteady model to gaining an understanding of the proposed barrage's influence on river behaviour. The daily discharges of the Tigris River provided as the upstream boundary conditions, wh

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Kinetic of Alkaloids Extraction from Plant by Batch Pertraction in Rotating Discs Contactor
...Show More Authors

A liquid membrane process of Alkaloids extraction from Datura Innoxia solution was studied applying pertraction process in rotating discs contactor (RDC). Decane as a liquid membrane and dilute sulphuric acid as stripping solution were used. The effect of the fundamental parameters influencing the transport process, eg type of solvent used, effect of disks speed, amount of liquid membrane and effect of pH for feed and strip solution. The transport of alkaloids was analysed on the basis of kinetic laws of two consecutive irreversible first order reactions. Thus, the kinetic parameters (k1, k1,, tmax, and) for the transport of alkaloids were determined. The effect of organic membrane type on percentage of Alkaloids transport was found to be i

... Show More
Publication Date
Sat Mar 13 2021
Journal Name
Al-nahrain Journal Of Science
Hiding Multi Short Audio Signals in Color Image by using Fast Fourier Transform
...Show More Authors

Many purposes require communicating audio files between the users using different applications of social media. The security level of these applications is limited; at the same time many audio files are secured and must be accessed by authorized persons only, while, most present works attempt to hide single audio file in certain cover media. In this paper, a new approach of hiding three audio signals with unequal sizes in single color digital image has been proposed using the frequencies transform of this image. In the proposed approach, the Fast Fourier Transform was adopted where each audio signal is embedded in specific region with high frequencies in the frequency spectrum of the cover image to sa

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sat Dec 15 2018
Journal Name
Revista De Chimie
Determination of Ethanol in Fermented Broth by Headspace Gas Chromatography using Capillary Column
...Show More Authors

The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which

... Show More
Crossref (4)
Crossref
Publication Date
Mon Apr 09 2018
Journal Name
Al-khwarizmi Engineering Journal
Creating Through Points in Linear Function with Parabolic Blends Path by Optimization Method
...Show More Authors

The linear segment with parabolic blend (LSPB) trajectory deviates from the specified waypoints. It is restricted to that the acceleration must be sufficiently high. In this work, it is proposed to engage modified LSPB trajectory with particle swarm optimization (PSO) so as to create through points on the trajectory. The assumption of normal LSPB method that parabolic part is centered in time around waypoints is replaced by proposed coefficients for calculating the time duration of the linear part. These coefficients are functions of velocities between through points. The velocities are obtained by PSO so as to force the LSPB trajectory passing exactly through the specified path points. Also, relations for velocity correction and exact v

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Feb 01 2010
Journal Name
Food Chemistry
Determination of aflatoxins in animal feeds by HPLC with multifunctional column clean-up
...Show More Authors

A reversed-phase HPLC method with fluorescence detection for the determination of the aflatoxins B1, B2, G1 and G2 in 42 animal feeds, comprising corn (16), soya bean meal (8), mixed meal (13), sunflower, wheat, canola, palm kernel, copra meals (1 each) was carried out. The samples were first extracted using acetonitrile:water (9:1), and was further cleaned-up using a multifunctional column. Optimum conditions for the extraction and chromatographic separation were investigated. By adopting an isocratic chromatographic system using a mobile phase comprising acetonitrile:methanol:water (8:27:65, v/v/v), the separation of the four aflatoxins was possible within 30 min. Recoveries for aflatoxins B1, B2, G1 and G2 were 98 ± 0.7%, 95 ± 1.0%, 94

... Show More
View Publication
Scopus (122)
Crossref (108)
Scopus Clarivate Crossref
Publication Date
Sat Sep 01 2018
Journal Name
Food Chemistry
Rapid determination of thiabendazole in juice by SERS coupled with novel gold nanosubstrates
...Show More Authors

View Publication
Scopus (130)
Crossref (129)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Analysis of wake effects induced by heavy ion tracks in titanium nitride ceramic
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref