Preferred Language
Articles
/
9RZ-uIcBVTCNdQwCeV5u
Predicate the Ability of Extracorporeal Shock Wave Lithotripsy (ESWL) to treat the Kidney Stones by used Combined Classifier
...Show More Authors

Extracorporeal Shock Wave Lithotripsy (ESWL) is the most commonplace remedy for kidney stone. Shock waves from outside the body frame are centered at a kidney stone inflicting the stone to fragment. The success of the (ESWL) treatment is based on some variables such as age, sex, stone quantity stone period and so on. Thus, the prediction the success of remedy by this method is so important for professionals to make a decision to continue using (ESWL) or tousing another remedy technique. In this study, a prediction system for (ESWL) treatment by used three techniques of mixing classifiers, which is Product Rule (PR), Neural Network (NN) and the proposed classifier called Nested Combined Classifier (NCC). The samples had been taken from 2850 actual sufferers cases that had been treated at Urology and Nephrology center of Iraq. The results from three cases have been compared to actual treatment results of (ESWL) for trained and non-trained cases and compared the results of three models. The results show that (NCC) approach is the most accurate method in prediction the efficient of uses (ESWL) remedy in treatment the kidney stone.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Nov 01 2025
Journal Name
Russian Journal Of General Chemistry
Synthesis, Antibacterial Activity, and Molecular Docking Study of Some New Azo Derivatives Based on 2(4-Aminophenyl)-5-Substituted 1,3,4-Oxadiazole
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Clarivate Crossref
Publication Date
Sat Oct 03 2026
Journal Name
Journal Of Physical Education
Predicting Grip Angle Using Some Kinematical Variables Of Leaving and Flight In Parallel Bar In Men's Gymnastics (Qatar 2016)
...Show More Authors

View Publication
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Detection a New Antiseptic Resistant Variant of qac Gene in Some Multi Drug Resistant Staphylococcus aureus Isolated from Different Clinical Sources
...Show More Authors

The increasing use of antiseptic compounds creates selective pressure cause emergence of antiseptic resistance among Staphylococcus aureus .Resistance mechanism of antiseptic is driven mainly by multi drug resistant (MDR) efflux protein.Sixty five isolates of S.aureuswere collected from different clinical sources and subjected to 11 antibiotics most of them are recognized by efflux systems as extruded substrates. Range of efflux activity was estimated using cartwheel method. Simultaneous discrimination of antiseptic coding genes (qacA/B, smr and norA)as well as nuc and mecA genes among multidrug resistantS.aureus(MRSA) isolates was preformed using multiplex PCR assay

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Sep 27 2020
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of an Instructional Program Concerning Healthy Lifestyle on Patients’ Attitudes after Percutaneous Coronary Intervention at Cardiac Centers in Baghdad City
...Show More Authors

Abstract:

Objective: The study’s aim to evaluate the effectiveness of instructional program about healthy lifestyle on patients’ attitudes after undergoing percutaneous coronary intervention.

Methodology: Quasi-experimental design/ has been utilized for the current study starting from December 2018 to March 2020 to achieve the objectives of the study. Non-probability (purposive) sample of 60 patients was divided into intervention and control groups. Data were analyzed by the application of descriptive and inferential statistical methods.

Results: findings reported that before intervention both study and control groups demonstrated low total mean of score relat

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 01 2018
Journal Name
Research Journal Of Pharmaceutical, Biological And Chemical
Synthesis and characterization of azo dyes ligands complexes with Ni (II) and Cu (II) and studies their industrial and bacterial application
...Show More Authors

1-[4-(4-Acetyl-2-hydroxy-phenylazo)-phenyl]-ethanone (L1) and 1-[3-Hydroxy-4(4-nitro-phenylazo)-phenyl]-ethanone (L2) were readied by combination the diazonium salts of amines with 3-hydroxyacetophenone. (C.H.N) analyses, infrared spectra, UV–vis electronic absorption spectra, 1H and 13CNMR spectral mechanisms are use to identified of the ligands. Complexes of Ni+2 and Cu+2 were performed as well depicted. The formation of complexes has been identified by using atomic absorption of flame, elemental analysis, infrared spectra and UV-Vis spectral process as well conductivity and magnetic quantifications. Nature of compounds produced have been studied obeyed the mole ratio and continuous contrast methods, Beer's law followed during a concent

... Show More
Publication Date
Tue Sep 01 2020
Journal Name
Biochemical And Cellular Archives
SYNTHESIS, SPECTRAL AND THERMAL CHARACTERIZATION OF NI(II), CU(II) AND ZN(II) COMPLEXES WITH NEW LIGAND TOWARDS POTENTIAL BIOLOGICAL APPLICATION
...Show More Authors

Series of new complexes of the type [M2 (L)Cl4 ] are prepared from the new ligand[N1 ,N4 -bis(benzo[d]thiazol-2- yl)succinamide (L) derived from ethan-1,2-dicarbonyl chloride and 2-aminobenzothiozole,where, M= Ni(ii), Cu(ii) and Zn(ii) alsocomplexes of mix-ligands, the type [M(L)(8-HQ)]Cl, where, M = Ni(ii), Cu(ii) and Zn(ii),8-HQ= 8-Hydroxyquinoline. Chemical forms are obtained from their 1 H, 13CNMR, Mass spectra (for (L)), FT-IR and U.V spectrum, melting point, molar conduct.Using flame (AA), % M is determined in the complexes.The content of C, H, N and S in the (L) and its complexes was specified. Magnetic susceptibility and thermal analysis (TGA) of prepared compounds were measured.The propose geometry for all complexes[M2 (L)Cl4 ] wa

... Show More
Publication Date
Wed Sep 02 2020
Journal Name
International Journal Of Pharmaceutical Research
A Study of Anti-Fungal Activity for Some Antibiotics Against Aspergillus spp. and Candida spp. in Iraqi patients with Diabetes Mellitus
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Russian Electronic Journal Of Radiology
COHORT COMPARATIVE STUDY OF COVID-19 VACCINATED AND NON-VACCINATED PATIENTS DEPENDING ON CT CHEST FINDINGS BETWEEN IRAQI AND JORDANIAN POPULATION
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Geological Journal
Multiple and Coherent Noise Removal from X-Profile 2D Seismic Data of Southern Iraq Using Normal Move Out-Frequency Wavenumber Technique
...Show More Authors

Multiple eliminations (de-multiple) are one of seismic processing steps to remove their effects and delineate the correct primary refractors. Using normal move out to flatten primaries is the way to eliminate multiples through transforming these data to frequency-wavenumber domain. The flatten primaries are aligned with zero axis of the frequency-wavenumber domain and any other reflection types (multiples and random noise) are distributed elsewhere. Dip-filter is applied to pass the aligned data and reject others will separate primaries from multiple after transforming the data back from frequency-wavenumber domain to time-distance domain. For that, a suggested name for this technique as normal move out- frequency-wavenumber domain

... Show More
View Publication
Scopus (3)
Scopus Crossref