Effects of non-uniform fin arrangement and size on the thermal response of a vertical latent heat triple-tube heat exchanger
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Nov 14 2022
Journal Name
Physica Scripta
A wavelet-based collocation technique to find the discontinuous heat source in inverse heat conduction problems
...Show More Authors
Abstract<p>This paper is devoted to an inverse problem of determining discontinuous space-wise dependent heat source in a linear parabolic equation from the measurements at the final moment. In the existing literature, a considerably accurate solution to the inverse problems with an unknown space-wise dependent heat source is impossible without introducing any type of regularization method but here we have to determine the unknown discontinuous space-wise dependent heat source accurately using the Haar wavelet collocation method (HWCM) without applying the regularization technique. This HWCM is based on finite-difference and Haar wavelets approximation to the inverse problem. In contrast to othe</p> ... Show More
View Publication
Scopus (14)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Non-thermal plasma effects on of structural and optical properties of Nio:Li thin films prepared by the spray pyrolysis technique
...Show More Authors

In this research ,Undoped Nio and 1%Li doped Nio thin films were deposited utilizing chemical spray pyrolysis on the glass substrates heated (450C). The effects of non-thermal plasma on the structural and optical properties were studied. XRD measurement shows that Nio and Nio:1%Li films were found to be polycrystalline and have cubic structure with a preferred orientation (111). Decreased crystal size after exposure especially at (7) sec. AFM data indicate that the surface roughness average and (RMS) values of the prepared doped films are increasing after exposure to plasma, the transmittance increases after doped samples exposure to plasma, it was found that the energy gap value decreased when doped samples exposure to plasma, also, thickn

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
Effects of Non-Thermal Argon Plasma Produced at Atmospheric Pressure on the Optical Properties of CdO Thin Films
...Show More Authors

In this paper the effect of nonthermal atmospheric argon plasma on the optical properties of the cadmium oxide CdO thin films prepared by chemical spray pyrolysis was studied. The prepared films were exposed to different time intervals (0, 5, 10, 15, 20) min. For every sample, the transmittance, Absorbance, absorption coefficient, energy gap, extinction coefficient and dielectric constant were studied. It is found that the transmittance and the energy gap increased with exposure time, and absorption. Absorption coefficient, extinction coefficient, dielectric constant decreased with time of exposure to the argon plasma

View Publication Preview PDF
Scopus (20)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Fri Nov 11 2022
Journal Name
Eurasian Journal Of Physics, Chemistry And Mathematics
Influence of thermophoresis and thermal radiation on mass transfer and heat of Three Dimensional maxwell fluid in presence of Magnetic field
...Show More Authors

The study is about Maxwell , three dimensions of non – Newtonian fluid. Method of th Homotopy applied to analysis mass transfer and heat with thermophoresis effects. (Sc), Impact of therrmophoretic (𝜏), magnetic (M), Biot (γ), radiation (Rd),Schmidt Prandtle (Pr) parameters and ratio parameter(β) on concentration, temperature are offered in the paper.

Publication Date
Tue Nov 01 2022
Journal Name
Computers And Electronics In Agriculture
A novel heat-pulse probe for measuring soil thermal conductivity: Field test under different tillage practices
...Show More Authors

View Publication
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
Experimental Investigation Utilizing Thermal Image Technique to the Heat Transfer Enhancement Using Oscillated Fins
...Show More Authors

Heat transfer around a flat plate fin integrated with piezoelectric actuator used as oscillated fin in laminar flow has been studied experimentally utilizing thermal image camera. This study is performed
for fixed and oscillated single and triple fins. Different substrate-fin models have been tested, using fins of (35mm and 50mm) height, two sets of triple fins of (3mm and 6mm) spacing and three frequencies
applied to piezoelectric actuator (5, 30 and 50HZ). All tests are carried out for (0.5 m/s and 3m/s) in subsonic open type wind tunnel to evaluate temperature distribution, local and average Nusselt number (Nu) along the fin. It is observed, that the heat transfer enhancement with oscillation is significant compared to without o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 11 2023
Journal Name
J. Of Kirkuk Univ. For Agri. Sci.
THE HARMFUL CONSEQUENCES OF HEAT STRESS ON CHICKENS INDUSTRY
...Show More Authors

This article dealt with identifying the importance of heat stress in poultry flocks and the damages resulting from the production of eggs and meat and the spread of pathogens, in addition to that ways to mitigate the harmful effects of heat stress, including physiological, nutritional, engineering and genetics, in order to ensure preservation of the product and reduce damages

View Publication Preview PDF
Publication Date
Sun Jun 30 2019
Journal Name
Journal Of Engineering
Numerical Study of Fluid Flow and Heat Transfer Characteristics in Solid and Perforated Finned Heat Sinks Utilizing a Piezoelectric Fan
...Show More Authors

Numerical study is adapted to combine between piezoelectric fan as a turbulent air flow generator and perforated finned heat sinks. A single piezoelectric fan with different tip amplitudes placed eccentrically at the duct entrance. The problem of solid and perforated finned heat sinks is solved and analyzed numerically by using Ansys 17.2 fluent, and solving three dimensional energy and Navier–Stokes equations that set with RNG based k−ε scalable wall function turbulent model. Finite volume algorithm is used to solve both phases of solid and fluid. Calculations are done for three values of piezoelectric fan amplitudes 25 mm, 30 mm, and 40 mm, respectively. Results of this numerical study are compared with previous b

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 31 2020
Journal Name
International Journal Of Heat And Technology
Enhancement of Natural Convection Heat Transfer of Hybrid Design Heat Sink
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Oct 25 2017
Journal Name
European Journal Of Environmental And Civil Engineering
Effect of saturation on response of a single pile embedded in saturated sandy soil to vertical vibration
...Show More Authors

View Publication