Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesisMethods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
The study aimed to assess the level of ANG‑2 in MM patients at diagnosis and in remission state and elaborate on its correlation with interleukin‑6 (IL‑6) and beta‑2 microglobulin (B2M) levels. Sixty MM patients; 20 newly diagnosed (ND), and 40 patients in remission were included. Twenty healthy individuals were included as a control group. Plasma levels of ANG‑2, B2M, and IL‑6 were tested by enzyme‑lin ked immunosorbent assay. There are significant statistical differences between ND patients and those in remission in hemoglobin, neutrophil count, blood urea, serum creatinine, glomerular filtration rate, B2M, IL6, and ANG‑2 (P = 0.001, 0.033, 0.005, 0.001, 0.001, 0.001, 0.004, and 0.001, respectively). ANG‑2 showed signifi
... Show MoreThe research intent evaluates the performance of material technical department / Technical College -Baghdad.
The study depend on the descriptive analytical approach to determine and treating the variables to get data and information that related to study, the researchers depended on questionnaire designed for this purpose and contains eight main dimensions that’s are scientific reference , academy course, staff member , administrative system, physical facilities , student ,scientific research, graduate service , in addition each dimension involved (5) items contacted with mean dimensions, which translate aspects of performance evaluation, the questionnaire applied on two samples staff member
... Show MoreFor this research, the utilisation of electrocoagulation (EC) toremove theciprofloxacin (CIP) and levofloxacin (LVX) from aqueous solutions was examined. The effective removal efficiencies are 93.47% for CIP and 88.00% for LVX, under optimum conditions. The adsorption isotherm models with suitable mechanisms were applied to determine the elimination of CIP and LVX utilizingtheEC method. Thefindingsshowed the adsorption of CIP and LVX on iron hydroxide flocs followed the Sips isotherm, with correlation coefficient values (R2) of 0.939 and 0.937. Threekinetic models were reviewed to determine the accurate CIP and LVX elimination methods using the EC method. The results showed that itfittedfor the second-order model, which indicated that the c
... Show MoreAbstract Organic compounds with pyrazole cores have a variety of uses, notably in the pharmaceutical and agrochemical sectors. The interest in creating pyrazole compounds, examining their many features, and looking for potential uses is growing. Our work has concert with synthesis of chalcones and pyrazolines, then finally pyrazoline-aniline derivatives and evaluation their anti-inflammatory, antibacterial and antifungal activities
Heterocyclic compounds are crucial for medicinal chemistry and the development of therapeutic agents like broad-spectrum antibiotics. This study devised a facile procedure to synthesize novel antimicrobial bicyclic heterocycles from 2-mercapto-3-phenylquinazolin-4(3H)-one. Advanced analytical techniques including 1 H and 13C NMR, elemental analysis, and FT-IR spectroscopy characterized the intricate chemical structures of the products. In vitro assays tested the heterocycles against aerobic and anaerobic bacterial strains using fluconazole and ciprofloxacin as antifungal and antibacterial controls. Results demonstrated the formidable broad-spectrum antibacterial and antifungal activities of the synthesized compounds, with growth inhibition
... Show MoreFor this research, the utilisation of electrocoagulation (EC) toremove theciprofloxacin (CIP) and levofloxacin (LVX) from aqueous solutions was examined. The effective removal efficiencies are 93.47% for CIP and 88.00% for LVX, under optimum conditions. The adsorption isotherm models with suitable mechanisms were applied to determine the elimination of CIP and LVX utilizingtheEC method. Thefindingsshowed the adsorption of CIP and LVX on iron hydroxide flocs followed the Sips isotherm, with correlation coefficient values (R2) of 0.939 and 0.937. Threekinetic models were reviewed to determine the accurate CIP and LVX elimination methods using the EC method. The results showed that itfittedfor the second-order model, which indicated that the c
... Show MoreTo perform a secure evaluation of Indoor Design data, the research introduces a Cyber-Neutrosophic Model, which utilizes AES-256 encryption, Role-Based Access Control, and real-time anomaly detection. It measures the percentage of unpredictability, insecurity, and variance present within model features. Also, it provides reliable data security. Similar features have been identified between the final results of the study, corresponding to the Cyber-Neutrosophic Model analysis, and the cybersecurity layer helped mitigate attacks. It is worth noting that Anomaly Detection successfully achieved response times of less than 2.5 seconds, demonstrating that the model can maintain its integrity while providing privacy. Using neutrosophic sim
... Show MoreIn data mining, classification is a form of data analysis that can be used to extract models describing important data classes. Two of the well known algorithms used in data mining classification are Backpropagation Neural Network (BNN) and Naïve Bayesian (NB). This paper investigates the performance of these two classification methods using the Car Evaluation dataset. Two models were built for both algorithms and the results were compared. Our experimental results indicated that the BNN classifier yield higher accuracy as compared to the NB classifier but it is less efficient because it is time-consuming and difficult to analyze due to its black-box implementation.