Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesisMethods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
Abstract : This research is concerned with studying the best type and method of irrigation as well as the best cultivated area to reduce the cost of producing dunums of wheat crop in Iraq , and was based on data taken from the Ministry of Planning / Central Statistical Organization About cost of wheat crop production for (12) Iraqi governorates except Kurdistan, Nineveh, Salah al-Din, Anbar) and the sample size (554) according to the cost survey carried out by the Ministry of Planning / Central Statistical Organization for 2017, The results of the research showed that there are significant statistical differences between production costs when using t
... Show MoreObserved mosques with the advent of Islam under the auspices of care being the houses of God Almighty, and I like parts of the ground to him, the center of radiation spiritual, intellectual and ideological in the lives of Muslims, was the most important cultural and architectural evidence built by Muslims voicing their deep faith and serenity Aqidthm.valmsadjad better reflecting the reality of communication between the person and his Lord, because he is the most important building of permanence and survival, making it imperative designed the best visual forms both externally and internally.Mosques have been characterized in the United Arab Emirates distinct characteristics in terms of building elements of construction in general, and the
... Show MoreBackground: Glass ionomers have good biocompatibility and the ability to adhere to both enamel and dentin. However, they have certain demerits, mainly low tensile and compressive strengths. Therefore, this study was done to assess consistency and compressive strength of glass ionomer reinforced by different amount of hydroxyapatite. Materials and Methods: In this study hydroxyapatite materials were added to glass ionomer cement at different ratios, 10%, 15%, 20%, 25% and 30% (by weight). The standard consistency test described in America dental association (ADA) specification No. 8 was used, so that all new base materials could be conveniently mixed and the results would be of comparable value and the compressive strength test described by
... Show MoreThe aim of this paper is to find a new method for solving a system of linear initial value problems of ordinary differential equation using approximation technique by two-point osculatory interpolation with the fit equal numbers of derivatives at the end points of an interval [0, 1] and compared the results with conventional methods and is shown to be that seems to converge faster and more accurately than the conventional methods.
This research seeks to explore the impact of notifications on enhancing user engagement with websites, primarily through user subscriptions and their interaction with notifications on these websites. The significance of this study lies in its implications for crafting compelling headlines that capture users' attention, streamline their access to journalistic content, and align with the objectives and editorial policies of news websites. It sheds light on the factors influencing users' preferences for specific notifications and their engagement with content based on their individual interests, motivations, and the satisfaction derived from such interactions.
The researcher has reached several key findings, inc
مستخلص البحث كان الهدف من البحث هو معرفة نسب نجاح وفشل بعض المهارات الهجومية المركبة من ثلاث مهارات بكرة السلة للشباب.، إذ لوحظ بأنه لا تكتمل عملية التقدم من خلال إتقان المهارات الأساسية الهجومية المفردة فقط وإنما في القدرة على الدقة والثبات في أداء الربط فيما بينها (التركيب)، وعكس ما تقدم يعد واحد من الأسباب التي تسبب ضعفاً في المستوى ومما يزيد من الأخطاء في الأداء تبعاً لذلك. وفي ضوء ما تقدم تم تصوير ست مباري
... Show MoreKeys for 22 species representing 10 genera of Thripidae were provided collection of
samples carried out during 1999-2001 in different localities in the middle of Iraq. Of them
four species are described as new to science, Frankliniella megacephala sp. nov; Retithrips
bagdadensis sp. nov; Chirothrips imperatus sp. nov; Taeniothrips tigridis sp. nov; Another
fourteen species are recorded for the first time in Iraq; Thrips meridionalis (Pri.);
Microcephalothrips abdominils (Crawford Scolothrips sexmaculatus (Pergande),);Scolothrips
pallidus (Beach); Scritothrips mangiferae Pri.; Frankliniella tritici Bagnall; Frankliniella
schultzie Trybom; Frankliniella unicolor Morgan; Retithrips aegypticus Marchal; Retithrips
java
Background: The restoration of bone continuity and bone union are complex processes, and their success is determined by the effectiveness of osteosynthesis. The use of plants for healing purposes predates human history and forms the source of current modern medicine The aim of this study: It was histological evaluation of effect of topical application of flavonoid on healing of induced bone defect in rabbit tibia. Material and method: Twenty-four Adult New Zealand rabbits used in this study, they were divided into four groups for the healing periods (3days, 1,2, and 4weeks) Two holes were induced in rabbit tibia one on the left side and has been left to heal normally as control. While, the other hole made on the right side filled with flavo
... Show MoreObjectives Dental implant is a revolution in dentistry; some shortages are still a focus of research. This study use long duration of radiofrequency (RF)–magnetron sputtering to coat titanium (Ti) implant with hydroxyapatite (HA) to obtain a uniform, strongly adhered in a few micrometers in thickness. Materials and Methods Two types of substrates, discs and root form cylinders were prepared using a grade 1 commercially pure (CP) Ti rod. A RF–magnetron sputtering device was used to coat specimens with HA. Magnetron sputtering was set at 150 W for 22 hours at 100°C under continuous argon gas flow and substrate rotation at 10 rpm. Coat properties were evaluated via field emission scanning electron microscopy (FESEM), scanning electro
... Show More