Preferred Language
Articles
/
8xcQS48BVTCNdQwCP2ks
Endothelin-1 is a surrogate biomarker link severe periodontitis and endothelial dysfunction in hypertensive patients: The potential nexus
...Show More Authors

Aim and Objectives: The objective of this study was to illustrate the link between periodontitis (PO) and endothelial dysfunction in hypertensive patients. Materials and Methods: This cross‑sectional study involved 53 hypertensive patients with or without PO compared with 28 healthy controls. On the basis of the study protocol, the participants were divided into three groups: Group (1): 24 patients with hypertension only, Group (2): 29 patients with hypertension and PO, and Group (3): 28 healthy controls. Lipid profile, endothelin‑1 (ET‑1), and high‑sensitivity C‑reactive protein (hs‑CRP) were measured. Blood pressure and body mass index (BMI) were evaluated. Diagnostic criteria of severe PO periodontal indices including plaque index, gingival index, and community periodontal index were estimated. Data collected during the study were analyzed using analysis of variance followed by Bonferroni post hoc test and unpaired t‑test (IBM SPSS Statistics for Windows, version 20.0, 2014, IBM, Armonk, NY). Results: BMI was not differed in both groups, P = 0.08. Systolic blood pressure and diastolic blood pressure were high in hypertensive patients with PO compared with hypertensive patients only, P = 0.04 and P = 0.03, respectively. Moreover, hypertensive patients with PO showed significant dyslipidemic status compared with hypertensive patients only (P < 0.05). Biomarker of endothelial dysfunction (ET‑1) was elevated in patients with PO (67.54 ± 13.56 pg/mL) compared with hypertensive patients only (23.67 ± 9.63 pg/mL), P = 0.0001. hs‑CRP serum level was increased patients with PO compared with hypertensive patients only, P = 0.002. PO indices were high in patients with PO compared with hypertensive patients only, P < 0.01. Conclusion: ET‑1 serum level is elevated in hypertensive patients with severe PO and correlated with cardio‑metabolic complications, mainly endothelial dysfunction. Therefore, ET‑1 serum level is regarded as a surrogate biomarker link PO with risk of endothelial dysfunction.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
The Effect of Different Types of Separating Medium On Some Physical Properties of Processing Acrylic Denture-base with Two Investment Materials: A comparative Study
...Show More Authors

Objective(s): In the present study, glycerin is used as a substitute for tin-foil and cold mold seal (Alginate mould seal)
in the process of curing heat and cold-cure acrylic resin denture base against stone and plaster.
Methodology: 60 specimens were prepared from heat-cure acrylic resin and cold-cure acrylic resin denture base. The
study includes 12 groups of specimens depending on the type of processing, investment material and type of
separating medium that are used in curing process. Each group of them contains 5 specimens for each test.
Some of physical properties of the processed acrylic denture base that (water sorption and solubility) have been
compared with those processed using tin-foil and tin-foil substitut

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 19 2022
Journal Name
Gynecology And Obstetrics Case Report
A Case Report of Intrauterine Fetal Death with Three Loops of Umbilical Cord around Neck, Keratin Hair Treatment during Pregnancy Could be the Cause
...Show More Authors

Preview PDF
Publication Date
Wed Apr 10 2013
Journal Name
Journal Of The College Of Basic Education
Effect of heavy metal ions copper, cadmium and cobalt on the growth and reproduction of the aquatic fungus Saprolegnia hypogyna.
...Show More Authors

The current study aimed to evaluate the effect of the heavy metals copper, cadmium and cobalt when added individually, in combination and in combination on the growth and reproduction of the aquatic fungus Saprolegnia hypogyna.

Publication Date
Mon Jun 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Relationships between the Physical and Chemical Properties of Narrow Fractions Distilled From Mixed Kirkuk and Sharki-Baghdad Crude Oils
...Show More Authors

Mixed Kirkuk and Sharki-Baghdad crude oils were distilled into narrow fractions. The range of these narrow fractions were 10oC, starting from IBP to 350oC. The total distillates from mixed Kirkuk and Sharki-Baghdad crude oils were 58.25 vol % and 44.65 vol %, respectively.The hydrocarbons compositions (paraffin, naphthene, aromatic) in light fractions starting from IBP to 250oC were determined by using PONA analysis method. The results show that the paraffin content decreases with increasing mid percent boiling point of the fraction, while the naphthene, and aromatic increase with the increase of mid percent boiling point of mixed Kirkuk and Sharki-Baghdad crude oils. Three groups of empirical equations were developed for the prediction

... Show More
View Publication Preview PDF
Publication Date
Sun May 01 2022
Journal Name
Journal Of Engineering
Parametric Study of a Two-Phase Closed Thermosyphon Loop
...Show More Authors

A theoretical and experimental investigation was carried out to study the behavior of a two-phase closed thermosyphon loop (TPCTL) during steady-state operation using different working fluids. Three working fluids were investigated, i.e., distilled water, methanol, and ethanol. The TPCTL was constructed from an evaporator, condenser, and two pipelines (riser and downcomer). The driving force is the difference in pressure between the evaporator and condenser sections and the fluid returns to the heating section by gravity. In this study, the significant parameters used in the experiments were filling ratios (FR%) of 50%, 75%, and 100% and heat-input range at the evaporator section of 215-860.2 W. When the loop reached to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Journal Of Economics And Administrative Sciences
Bayes Estimator as a Function of Some Classical Estimator
...Show More Authors

Maximum likelihood estimation method, uniformly minimum variance unbiased estimation method and minimum mean square error estimation, as classical estimation procedures, are frequently used for parameter estimation in statistics, which assuming the parameter is constant , while Bayes method assuming the parameter is random variable and hence the Bayes estimator is an estimator which minimize the Bayes risk for each value the random observable and for square error lose function the Bayes estimator is the posterior mean. It is well known that the Bayesian estimation is hardly used as a parameter estimation technique due to some difficulties to finding a prior distribution.

The interest of this paper is that

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 25 2017
Journal Name
Oriental Journal Of Physical Sciences
Evaluating a Chemical/Biological Laboratory to Promote Safety Measures
...Show More Authors

The Department of Chemical and Biological Engineering, Al-Khwarizmi College of Engineering at Baghdad University has lately renovated its own research laboratories to comply with international safety measures and conduct undergraduate and postgraduate research. In this regard, the department has harnessed some amenities within the college to establish these laboratories taking into accounts creating a convenient, safe, and developed working environment for both researchers and students. A precise procedure was followed to establish this laboratory which includes providing new bench tops which offer spacious working places for workers. These benches were supplied with power points, gas, water, and compressed air outlets. In addition,

... Show More
View Publication
Crossref
Publication Date
Tue Jul 01 2014
Journal Name
International Journal Of Artificial Intelligence And Mechatronics
Building a Three-Axis CNC Milling Machine Control System
...Show More Authors

CNC machines are widely used in production fields since they produce similar parts in a minimum time, at higher speed and with possibly minimum error. A control system is designed, implemented and tested to control the operation of a laboratory CNC milling machine having three axes that are moved by using a stepper motor attached to each axis. The control system includes two parts, hardware part and software part, the hardware part used a PC (works as controller) connected to the CNC machine through its parallel port by using designed interface circuit. The software part includes the algorithms needed to control the CNC. The sample needs to be machined is drawn by using one of the drawing software like AUTOCAD or 3D MAX and is saved in a we

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Proceedings Of The Eleventh International Network Conference (inc 2016)
A review on power consumption reduction techniques on OFDM
...Show More Authors

Scopus (2)
Scopus
Publication Date
Fri Sep 01 2023
Journal Name
Biores Scientica
Type IV Flexor Digitorum Profundus Avulsion: A Case Report
...Show More Authors

Abstract The avulsion of the flexor digitorum profundus, also known as the jersey finger, is a well-known injury that can be treated surgically. It has been classified into four types, among them type IV which involves tendon avulsion from an associated bony fragment with subsequent retraction to the palm or proximal interphalangeal joint is very rare. We present a case of type IV injury in a 45-year-old man with a pulling-on injury. The repair followed a pull-out technique (reinserting the tendon into the avulsed fragment); the entire reduction was tied over a button on the dorsal aspect of the nail and was augmented with a volar plate. The case was reported due to its rarity. We found that early surgical management of this problem greatly

... Show More