Preferred Language
Articles
/
8xYmaIcBVTCNdQwCYEle
Evaluation of Apical Transportation and Curve Straightening of Curved Root Canals after Preparation with Different Nickel - Titanium Rotary Systems (Comparative in Vitro Study)
...Show More Authors

The goals of endodontic preparation were to shape and clean the space of the root canal and remove microorganisms, affected dentin and pulp, the apical foramen and the canal curve should be protected from being transported during endodontic canal preparation. The aim of this study was to evaluate the curve straightening of curved root canals and apical transportation after preparation with four rotary systems. Forty mesial roots of the lower 1st molars teeth only the mesiobuccal canals were used, these roots were immersed into cold clear acrylic , the teeth roots divided into four groups according to rotary system used for preparation of the canals (ten roots for each group):. group I: ProTaper Next rotary system, group II: IRaCe Plus rotary system, group III: HeroShaper rotary system, group IV: ProTaper rotary system, instrumentation were done to size 30 master apical file and with copious irrigation, total amount of 10 ml of 2.5% of sodium hypochlorite (NaOCl) then rinsed the canals with distilled water 5 ml. radiograph was taken for all roots before and after instrumentation in one direction buccolingual using digital radiograph system. The degree of curve straightening of the root canal and the apical transportation were measured using Image J software and Adobe photoshop CS6 software. Statistical analysis was done and the result showed that group IV had the highest mean values in curve straightening and apical transportation, there were significant difference between group IV and all of the other groups and there were non- significant difference between group I , group II and group . All the four used rotary systems produced adequate geometry during canal preparations. However, some apical transportation in ProTaper group was seen, which might need a caution when used protaper in instrumentation of curved canal.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 05 2024
Journal Name
Anaesthesia, Pain & Intensive Care
A comparative study between tongue thickness measured by ultrasonography and thyromental distance in anticipation of difficult intubation
...Show More Authors

Background & objective: Difficult intubation remains a risk for patients undergoing general anesthesia (GA) or mechanical ventilation in an intensive care unit (ICU). Macroglossia is a known factor for difficult intubation. But it is not routine to assess the tongue size to predict difficult intubation. Studies are found deficient in comparing usefulness of measuring thyromental distance and the tongue thickness (TT) measured by ultrasonography to estimate difficult intubation. We compared tongue thickness measured by ultrasonography and thyromental distance as a means to anticipate difficult intubation. Methodology: A convenient sample of 60 patients; 32 males and 28 females, who were undergoing elective surgery with GA were i

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Thu Dec 27 2018
Journal Name
Revue Académique De La Recherche Juridique
The Scope of the Judge’s Authority in Completing a Contract and the Limitations Thereon – A Comparative Study
...Show More Authors

The contractual imbalance is perceived today by the majority of the doctrine as being one of the pitfalls to the execution of the contracts. As a result, most legislations grant judges the power to intervene to restore it. Granting the judge the power to complete the contract raises the question of the extent to which the judge can obtain such power. Is it an absolute authority that is not limited? If so, is it a broad discretion in which the judge operates in his conscience, or is it a power of limited scope by specific legal texts and conventions? This is what we will try to answer in this research.

View Publication
Publication Date
Fri Jun 03 2016
Journal Name
Iraqi Medical Journal
EVALUATION OF PATIENTS WITH CARPAL TUNNEL SYNDROME TREATED BY MINIMAL PALMAR INCISION (A PRELIMINARY STUDY)
...Show More Authors

Background : Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy of upper extremities and Open carpal tunnel release is the most frequent surgical procedure and the gold standard for cases that do not respond to conservative treatment. Aims :This study is used to evaluate the functional outcome of limited palmar mini-incision of carpal tunnel release. This study aims to determine the safety and symptomatic and functional efficacy of median nerve decompression with limited incision in carpal tunnel syndrome surgery. Patients and methods:Carpal tunnel release with a 1.5-2 cm limited palmar incision was performed on 20 patients. Patients were evaluated initially at one month after treatment according to symptom severity

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Analysis of curved optical absolute visual fates of super colony of Type II (SN II)
...Show More Authors

Were analyzed curved optical fates Almarchih absolute colony of the binary type, the Great Palmstqrh using mathematical relationships derived for that and that gave us the results closer to the results of the observed spectral Great Colonial

View Publication Preview PDF
Publication Date
Tue Oct 23 2018
Journal Name
Journal Of Economics And Administrative Sciences
Comparative study of between P chart and Multinomial Fuzzy quality control chart ( FM).
...Show More Authors

Quality is one of the important criteria to determine the success of product. So quality control is required for all stages of production to ensure a good final product with lowest possible losses. Control charts are the most important means used to monitor the quality and its accuracy is measured by quickly detecting unusual changes in the quality to maintain the product and reduce the costs and losses that may result from the defective items. There are different types of quality control charts and new types appeases involving the concept of fuzziness named multinomial fuzzy quality control chart (FM) , dividing the product to accepted and not may not be accurate therefore adding fuzziness concept to quality charts confirm and a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Journal Of The College Of Education For Women
COMPARATIVE STUDY FOR EDGE DETECTION OF NOISY IMAGE USING SOBEL AND LAPLACE OPERATORS
...Show More Authors

Many approaches of different complexity already exist to edge detection in
color images. Nevertheless, the question remains of how different are the results
when employing computational costly techniques instead of simple ones. This
paper presents a comparative study on two approaches to color edge detection to
reduce noise in image. The approaches are based on the Sobel operator and the
Laplace operator. Furthermore, an efficient algorithm for implementing the two
operators is presented. The operators have been applied to real images. The results
are presented in this paper. It is shown that the quality of the results increases by
using second derivative operator (Laplace operator). And noise reduced in a good

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 02 2023
Journal Name
Journal Of Engineering
Comparative Study between Recycled Fine and Coarse Aggregate Used in Roller Compacted Concrete Pavement
...Show More Authors

To decrease the impact on the environment of building waste, the recycled aggregate may be used in various sustainable engineering applications, such as roller compacted concrete pavement (RCCP). This research examined how using recycled aggregate as a partial replacement for natural aggregate as coarse or fine affected the mechanical properties of roller-compacted concrete pavement. The recycled aggregate was crushed and sieved to coarse and fine aggregate before being used in the roller-compacted concrete pavement. Compressive strength, splitting tensile strength, and flexural strength were all evaluated after the samples were prepared at 28 and 90 days of curing. According to the study's findings, the partial replacem

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Wed Sep 30 2015
Journal Name
College Of Islamic Sciences
The other day in the Holy Quran and the four Gospels: A comparative study
...Show More Authors

The other day in the Holy Quran and the four Gospels

View Publication Preview PDF
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
A Comparative Study between Transcutaneous Bilirubinometry and Total Serum Bilirubin Measurement in Jaundiced Newborns
...Show More Authors

Background: Drawing blood to measure total serum bilirubin is painful & time consuming. Transcutaneous bilirubinometer working by multiwavelength spectral reflectance from the skin surface on forehead or upper sternum is a quick & painless technique. 

Objectives: to compare the effectiveness of transcutaneous (over the upper sternum and forehead) and serum bilirubin measurement of neonate with jaundice.

Subjects and Methods: This is a cross sectional prospective study. It enrolled 175 jaundiced neonates & excluded those exposed to phototherapy. It was conducted at Child Central Teaching Hospi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Oral health status of patients after replacement of removable partial dentures after three years
...Show More Authors

Objective(s): To assess the effect of removable partial dentures on the abutment teeth in comparison with that of the
remaining dentition, and to investigate the effect of regular check up on periodontal health for patients using this
type of prosthesis.
Methodology: One hundred patients wearing removable partial dentures for at least three years included in the
study. Teeth used as direct or in direct retainers for the removable partial denture were considered as the study
group, while the remaining dentition in the same jaw was considered as the control group. The following periodontal
parameters were registered for each tooth, plaque and gingival indices, clinical attachment level and tooth mobility.
Patients were

... Show More
View Publication Preview PDF