The goals of endodontic preparation were to shape and clean the space of the root canal and remove microorganisms, affected dentin and pulp, the apical foramen and the canal curve should be protected from being transported during endodontic canal preparation. The aim of this study was to evaluate the curve straightening of curved root canals and apical transportation after preparation with four rotary systems. Forty mesial roots of the lower 1st molars teeth only the mesiobuccal canals were used, these roots were immersed into cold clear acrylic , the teeth roots divided into four groups according to rotary system used for preparation of the canals (ten roots for each group):. group I: ProTaper Next rotary system, group II: IRaCe Plus rotary system, group III: HeroShaper rotary system, group IV: ProTaper rotary system, instrumentation were done to size 30 master apical file and with copious irrigation, total amount of 10 ml of 2.5% of sodium hypochlorite (NaOCl) then rinsed the canals with distilled water 5 ml. radiograph was taken for all roots before and after instrumentation in one direction buccolingual using digital radiograph system. The degree of curve straightening of the root canal and the apical transportation were measured using Image J software and Adobe photoshop CS6 software. Statistical analysis was done and the result showed that group IV had the highest mean values in curve straightening and apical transportation, there were significant difference between group IV and all of the other groups and there were non- significant difference between group I , group II and group . All the four used rotary systems produced adequate geometry during canal preparations. However, some apical transportation in ProTaper group was seen, which might need a caution when used protaper in instrumentation of curved canal.
The full energy peak efficiency (ɛ) relation of HpGe detector is determined and compared with the "spectrum shape" relation of natural background (BG) for the (121.8-1408) keV energy range. A one liter Marinelli beaker soil standard containing the Eu-152 material is used in calibration and measurement. A MATLAB fitting program were used obtain the efficiency relation from the experimental values, and to obtain the BG "spectrum shape" relation from the count rates at the corresponding energy values used. The ɛ / BG factor values were 1.154 at the 121.8keV and increase with energy till reaching a maximum value of 4.358 at about 778keV energy and then decrease. These values may be used to extract efficiency from the BG values at the
... Show MoreNew Schiff base and their Mn(II),Co(II),Ni(II), Cu(II) and Hg(II) complexes formed by the condensation of O-phathaldehyde and ethylene diamine (2:1) to give ligand (L1) in the first step ,then the ligand (L1) with 2- aminophenol (1:2) to give ligand (L2) were prepared by classic addition through microwave method . These compounds (Ligands and complexes) have been diagnosed electronic spectra, FT-IR,1H-&13C-NMR (only ligand), magnetic susceptibility, elemental microanalysis and molar conductance measurements. Analytical values displayed that all the complexes appeared (metal: ligand) (1:1) ratio with the six chelation. All the compounds appear a high activity versus four types of bacteria such as; (Escherichia coli), (Sta
... Show MoreBackground: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium
... Show MoreTransparent nano- coating was prepared by Sol-Gel method from titanium dioxide TiO2 which has the ability to self-cleaning coating used for hospitals, laboratories, and places requiring permanent sterilization. Three primary colors are selected (red, blue, and yellow) as preliminary study to the effect of these colors on the nano-coating. Three traditional oil paints color were used as base, then coated by a layer of TiO2-Sol and deposited on the paints. The optical properties of TiO2-Sol were measured; the maximum absorption wavelength at (λmax=387 nm), the refractive index (n=1.4423) and the energy band gap (Eg=3.2 eV). The structure properties found by X-ray diffraction of TiO
Many complexes of 3,5-dimethyl-1H-pyrazol-1-yl phenyl methanone with Cr(III), Co(II), Ni(II), Cu(II) and Cd(II) were synthesized and characterized by FT-IR, UV/visible spectra, elemental analysis, room temperature magnetic susceptibility and molar conductivity. Cd(II) complex was expected to have tetrahedral structure while all the other complexes were expected to have an octahedral structure.