A pseudo-slug flow is a type of intermittent flow characterized by short, frothy, chaotic slugs that have a structure velocity lower than the mixture velocity and are not fully formed. It is essential to accurately estimate the transition from conventional slug (SL) flow to pseudo-slug (PSL) flow, and from SL to churn (CH), by precisely predicting the pressure losses. Recent research has showed that PSL and CH flows comprise a significant portion of the conventional flow pattern maps. This is particularly true in wellbores and pipelines with highly deviated large-diameter gas-condensate wellbores and pipelines. Several theoretical and experimental works studied the behavior of PSL and CH flows; however, few models have been suggested to predict SL/CH and are very limited for SL/PSL transitions. Based on the experimental data, an empirical model was suggested to predict the SL/PSL/CH transition for air/water upward inclined flow. The proposed model correlates the modified gas Froude number with the inclination angle and modified liquid Froude number. The inclined flow dataset includes 125 data points of SL, PSL, and CH covering angle of inclination (θ) from 2o to 89.4 °with a relatively large pipe diameter (D) of 0.1016 m. The developed model accurately predicted all data and captured the expected influence of inclination angle, pipe diameter, and gas density on the SL/PSL/CH transition. The developed model was tested favorably against three datasets (681 points) collected from twelve independent studies: 549 air/water two-phase points, 65 air/viscous liquid two-phase points, and 67 air/oil/water three-phase points.
|
A novel robust finite time disturbance observer (RFTDO) based on an independent output-finite time composite control (FTCC) scheme is proposed for an air conditioning-system temperature and humidity regulation. The variable air volume (VAV) of the system is represented by two first-order mathematical models for the temperature and humidity dynamics. In the temperature loop dynamics, a RFTDO temperature (RFTDO-T) and an FTCC temperature (FTCC-T) are designed to estimate and reject the lumped disturbances of the temperature subsystem. In the humidity loop, a robust output of the FTCC humidity (FTCC-H) and RFTDO humidity (RFTDO-H) are also designed to estimate and reject the lumped disturbances of the humidity subsystem. Based on Lyapunov theo
... Show MoreThe aim of this study was the discrimination of Salmonella isolated from chicken and their feed and drinking water for the epidemiological control of salmonellosis. Totally, 289 samples, including 217 chicken cloaca swabs, 46 water, and 26 feed samples were collected from five different farms in Karbala governorate, Iraq. Conventional bacteriology tests, API 20E, Vitek 2, and serology were used for bacterial identification. Random amplified polymorphic DNA (RAPD)-polymerase chain reaction (PCR) was applied to analyze the genetic relationships among Salmonella isolates. The isolation rate of Salmonella spp. was 21.1% (61/289). While the water samples constituted the highest rate (30.4%), a rate of
... Show MoreWater quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their performance is evaluated usin
... Show MoreWater quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their perfor
... Show MoreAn experimental and numerical study has been carried out to investigate the forced convection heat transfer by clean or dusty air in a two dimensional annulus enclosure filled with porous media (glass beads) between two vertical concentric cylinders. The outer cylinder is of (82 mm) outside diameters and the inner cylinder of (27 mm) outside diameter. Under steady state condition; the inner cylinder surface is maintained at a high temperature by applying a uniform heat flux and the outer cylinder surface at an ambient temperature. The investigation covered values of input power of (6.3, 4.884, 4.04 and 3.26 W), Reynolds number values of (300, 700, 1000, 1500, and 2000) and dust ratio values (density number N) of (2, 4, 6 and 8). A comput
... Show MoreThe current study was conducted to demonstrate the effects of air pollution on different biochemical parameters inCitrus aurantium plant and calculation the Air Pollution Tolerance Index (APTI). Five sites were selected tocollect plant leaves, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and closeto the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. Seasonalsamples were collected for the period from October 2016 to June 2017. Eleven biochemical parameters totalchlorophyll, ascorbic acid, leaf extract pH, relative water content, total nitrogen, total protein content, total sugarcontent, proline, electrical conductivity, cadmium and lead. The results of Citr
... Show MorePolycyclic aromatic hydrocarbons (PAHs) were measured in aerosol from air samples, which collected for the period from April 2012 to February 2013, in Baghdad city, at Daura Refinery. Aerosol samples were collected on cellulose fiber filters for 1.5 h in each site for the morning and evening time. These aerosol samples undergone soxhlet extraction.
After the extraction, 49 samples were analyzed by GC-MS in order to determin 16 PAH compounds. The parameters temperature, relative humidity and wind speed were measured during the measurement period. The PAH concentrations were different for location inside and outside Daura refinery. Naphthalene was the most abundant PAH detected in all points at the site sampling for all seasons. There i