A pseudo-slug flow is a type of intermittent flow characterized by short, frothy, chaotic slugs that have a structure velocity lower than the mixture velocity and are not fully formed. It is essential to accurately estimate the transition from conventional slug (SL) flow to pseudo-slug (PSL) flow, and from SL to churn (CH), by precisely predicting the pressure losses. Recent research has showed that PSL and CH flows comprise a significant portion of the conventional flow pattern maps. This is particularly true in wellbores and pipelines with highly deviated large-diameter gas-condensate wellbores and pipelines. Several theoretical and experimental works studied the behavior of PSL and CH flows; however, few models have been suggested to predict SL/CH and are very limited for SL/PSL transitions. Based on the experimental data, an empirical model was suggested to predict the SL/PSL/CH transition for air/water upward inclined flow. The proposed model correlates the modified gas Froude number with the inclination angle and modified liquid Froude number. The inclined flow dataset includes 125 data points of SL, PSL, and CH covering angle of inclination (θ) from 2o to 89.4 °with a relatively large pipe diameter (D) of 0.1016 m. The developed model accurately predicted all data and captured the expected influence of inclination angle, pipe diameter, and gas density on the SL/PSL/CH transition. The developed model was tested favorably against three datasets (681 points) collected from twelve independent studies: 549 air/water two-phase points, 65 air/viscous liquid two-phase points, and 67 air/oil/water three-phase points.
Lacing reinforcement plays a critical role in the design and performance of reinforced concrete (RC) slabs by distributing the applied loads more evenly across the slab, ensuring that no specific area of the slab is overloaded. In this study, nine slabs, divided into three groups according to the investigated parameters, were meticulously designed and evaluated to study the interplay between the lacing reinforcement and other key parameters. Each slab was crafted for simple support and was subjected to both static and repeated two-point load tests. The lacing reinforcement had an angle of 45° with various tension and lacing steel. The repeated-tested specimens with lacing reinforcement experienced smaller ductility than those of s
... Show MoreNew complexes have been prepared from the new ligand [2,2′‐(5,5‐dimethylcyclohexane‐1,3‐diylidene)bis(azan‐1‐yl‐1‐ylidene)dibenzoic acid] derived from 5,5‐dimethylcyclohexane‐1,3‐dione and 2‐aminobenzoic acid. Accordingly, its mono and binuclear Mn(II), Co(II), Cu(II), Zn(II), and Cd(II) complexes were prepared. The prepared components have been characterized by various spectroscopic techniques and elemental analysis. The thermal stability of the ligand and its complexes were performed by TGA. It was found that all the complexes have excellent thermal stability and do not contain water molecules within their structure, but the ligand has little stability. Additionally, theor
The Purpose of this research is analysis and discussion " The Effect of Insurace Company Capital Adequacy in it’s Profitafility: An Empirical Study compared the two insurance (national, Iraqi), for a period of one year (2005) and the year (2014), as it is framed theoretical side for two topics head adequacy money the insurance company, and the profitability of the insurance company, and I've been using the research methodology and analytical, in the analysis and measurement of the capital of the insurance company adequacy, and profitability of the company, as the capital adequacy ratio was measured by dividing the total capital available on the total capital rate risk, after measured and appreciated in two insurance research, while I u
... Show MoreThe factors influencing the financial market are rapidly becoming more complex. The impact of non-financial factors on the performance of a company’s common stock can increase in ways that were not previously expected. This study investigated how brand capital affects the risk of stock prices in Iraqi private banks listed on the Iraq Stock Exchange failing by identifying the likelihood of a crash caused by a negative deviation in the distribution of returns on ordinary shares. As a result, the current study’s concept is to review an analytical knowledge framework of the nature of that relationship, its changes, and its impact on the pricing of ordinary shares of the banks of the researched sector for the years 2009 to 2017, as w
... Show MoreA microbubble air flotation technique was used to remove chromium ions from simulated wastewater (e.g. water used for electroplating, textiles, paints and pigments, and tanning leather). Experimental parameters were investigated to analyze the flotation process and determine the removal efficiency. These parameters included the location of the sampling port from the bottom of the column, where the diffuser is located to the top of flotation column (30, 60, and 90 cm), the type of surfactant (anionic, SDS, or cationic, CTAB) and its concentration (5, 10, 15, and 20 mg/L), the pH of the initial solution (3, 5, 7, 9, and 11), the initial contaminant concentration (10, 20, 30, and 40 mg/L), the gas flow rate (0.1, 0.2, 0.3, and 0.5 L/mi
... Show More
In this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p
... Show MoreSolar collectors, in general, are utilized to convert the solar energy into heat energy, where it is employed to generate electricity. The non-concentrating solar collector with a circular shape was adopted in the present study. Ambient air is heated under a translucent roof where buoyant air is drawn from outside periphery towards the collector center (tower base). The present study is aimed to predict and visualize the thermal-hydrodynamic behavior for airflow under inclined roof of the solar air collector, SAC. Three-dimensional of the SAC model using the re-normalization group, RNG, k−ε turbulence viscus model is simulated. The simulation was carried out by using ANSYS-FLUENT 14.5. The simulation
... Show More