Preferred Language
Articles
/
8Res5I8BVTCNdQwCSX_O
Ultrasonic fetal Doppler and growth indices and their relation to immediate neonatal outcomes in different severities of maternal anemia
...Show More Authors

Doppler assessment may lead to intervention that reduces the risk of fetal brain damage. Aim of thestudy: to assess the relation between ultrasonic hemodynamic Doppler indices of middle cerebral and umbilical arteries (PI, RI), growth indices to immediate neonatal outcomes (weight, head & abdominal circumference, APGAR scores at 1 and 5 minutes and neonatal unit admission) in women with mild, moderate and severe anemia during pregnancy. Present study is a clinical prospective study carried out in Al-Elwiya Maternity Teaching Hospital during (January-Jun) 2019, all anemic pregnant women presented to Obstetrical wards in hospitals for emergency cesarean section were the study population. The final sample selected was 120 pregnant women. Ultrasound Doppler velocimetry measurements like middle cerebral artery-peak systolic velocity (MCA-PSV), middle cerebral artery-pulsatility index (MCA-PI), middle cerebral artery-resistance index (MCA-PR), umbilical artery-pulsatility index (UA-PI), umbilical artery- resistance index (UA-RI), middle cerebral artery to umbilical artery- resistance index ratio (MCA/UA-RI) and middle cerebral artery to umbilical artery- pulsatility index ratio (MCA/UA-PI) were measured. Neonates with less than7had low vital activities (appearance, pulse, grimace, activity, and respiration). Mean MCA-PI of anemic pregnant women with severe anemia was 1.4ms which was significantly lower than pregnant women with mild and moderate anemia, also mean MCA/UA-PI of anemic pregnant women with severe anemia was significantly lower than mild and moderate anemia with p-value <0.001. as well as the Mean neonatal HC of anemic pregnant women with severe anemia 30 cm which was significantly lower than HC of pregnant women with mild and moderate anemia (p=0.04), also mean neonatal AC of pregnant women with mild, moderate and severe, Current study showed no statistical difference in Apgar scores between the studies group, The validity results of MCA/UA-PI ratio regarding neonatal HC of anemic pregnant women are Sensitivity (22.2%), specificity (41.7%). Severe maternal anemia is found significantly associated with abnormal Doppler study middle cerebral artery to umbilical artery pulsatility index. so Doppler middle cerebral artery to umbilical artery pulsatility index has limited validity in the prediction of neonatal outcomes in anemic pregnant women.

Publication Date
Thu Feb 06 2020
Journal Name
Scientific Reports
Waste foundry sand/MgFe-layered double hydroxides composite material for efficient removal of Congo red dye from aqueous solution
...Show More Authors
Abstract<p>We aimed to obtain magnesium/iron (Mg/Fe)-layered double hydroxides (LDHs) nanoparticles-immobilized on waste foundry sand-a byproduct of the metal casting industry. XRD and FT-IR tests were applied to characterize the prepared sorbent. The results revealed that a new peak reflected LDHs nanoparticles. In addition, SEM-EDS mapping confirmed that the coating process was appropriate. Sorption tests for the interaction of this sorbent with an aqueous solution contaminated with Congo red dye revealed the efficacy of this material where the maximum adsorption capacity reached approximately 9127.08 mg/g. The pseudo-first-order and pseudo-second-order kinetic models helped to describe the sorption measure</p> ... Show More
Scopus (188)
Crossref (124)
Scopus Clarivate Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Experimental Study of Pre-Cast Reinforced Concrete Deep Beams (Hallow Core section) Retrofitting with Carbon Fiber Reinforced Polymer (CFRP)
...Show More Authors

Experimental programs based test results has been used as a means to find out the response of individual elements of structure. In the present study involves investigated behavior of five reinforced concrete deep beams of dimension (length 1200 x height 300 x width150mm) under two points concentrated load with shear span to depth ratio of (1.52), four of these beams with hallow core and
retrofit with carbon fiber reinforced polymer CFRP (with single or double or sides Strips). Two shapes of hallow are investigated (circle and square section) to evaluated the response of beams in case experimental behavior. Test on simply supported beam was performed in the laboratory & loaddeflection, strain of concrete data and crack pattern of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Non-Destructive Damage Assessment of Five Layers Fiber Glass / Polyester Composite Materials Laminated Plate by Using Lamb Waves Simulation
...Show More Authors

Composite materials are widely used in the engineered assets as aerospace structures, marine and air navigation owing to their high strength/weight ratios. Detection and identification of damage in the composite structures are considered as an important part of monitoring and repairing of structural systems during the service to avoid instantaneous failure. Effective cost and reliability are essential during the process of detecting. The Lamb wave method is an effective and sensitive technique to tiny damage and can be applied for structural health monitoring using low energy sensors; it can provide good information about the condition of the structure during its operation by analyzing the propagation of the wave in the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Surface Characterization of PEKK Modified by stron-tium –hydroxyapatite coating as implant material Via the magnetron sputtering Deposition technique
...Show More Authors

Background: The best material for dental implants is polyetherketoneketone (PEKK). However, this substance is neither osteoinductive nor osteoconductive, preventing direct bone apposition. Modifying the PEKK with bioactive elements like strontium hydroxyapatite is one method to overcome this (Sr-HA). Due to the technique's capacity to provide better control over the coating's properties, RF magnetron sputtering has been found to be a particularly useful technique for deposition. Materials and methods : With specific sputtering conditions, the RF magnetron technique was employed to provide a homogeneous and thin coating on Polyetherketoneketone substrates.. the coatings were characterized by Contact angle, adhesion test, X-ray

... Show More
Crossref (11)
Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Surface Characterization of PEKK Modified by stron-tium –hydroxyapatite coating as implant material Via the magnetron sputtering Deposition technique
...Show More Authors

Background: The best material for dental implants is polyetherketoneketone (PEKK). However, this substance is neither osteoinductive nor osteoconductive, preventing direct bone apposition. Modifying the PEKK with bioactive elements like strontium hydroxyapatite is one method to overcome this (Sr-HA). Due to the technique's capacity to provide better control over the coating's properties, RF magnetron sputtering has been found to be a particularly useful technique for deposition.

Materials and methods : With specific sputtering conditions, the RF magnetron technique was employed to provide a homogeneous and thin coating on Polyetherketoneketone substrates.. the coatings were characterized by Contact angle, adhesion test, X-ray dif

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (11)
Scopus Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Microporous And Mesoporous Materials
Using the ash of common water reeds as a silica source for producing high purity ZSM-5 zeolite microspheres
...Show More Authors

View Publication
Scopus (38)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Inorganic Chemistry Communications
Sustainable adsorptive removal of high concentration organic contaminants from water using biodegradable Gum-Acacia integrated magnetite nanoparticles hydrogel adsorbent
...Show More Authors

Release of industrial effluents comprising dyes in water bodies is one of the foremost causes of water pollution. Therefore, the proper and proficient treatment of these dyes contaminated left-over material before their release is crucial. Herein, an eco-friendly biological macromolecule Gum-Acacia (GA) integrated Fe3O4 nanoparticles composite hydrogel was manufactured via co-precipitation technique for effective adsorption of Congo red (CR) dye existing in water bodies. The as-prepared magnetic GA/Fe3O4 composite hydrogel was characterized by FTIR, XRD, EDX, VSM, SEM, and BET techniques. These studies discovered the fruitful fabrication of biodegradable magnetic GA/Fe3O4 composite hydrogel possessing porous structure with large surface are

... Show More
View Publication
Scopus (22)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
An An Accurate Estimation of Shear Wave Velocity Using Well Logging Data for Khasib Carbonate Reservoir - Amara Oil Field
...Show More Authors

   

Shear and compressional wave velocities, coupled with other petrophysical data, are vital in determining the dynamic modules magnitude in geomechanical studies and hydrocarbon reservoir characterization. But, due to field practices and high running cost, shear wave velocity may not available in all wells. In this paper, a statistical multivariate regression method is presented to predict the shear wave velocity for Khasib formation - Amara oil fields located in South- East of Iraq using well log compressional wave velocity, neutron porosity and density. The accuracy of the proposed correlation have been compared to other correlations. The results show that, the presented model provides accurate

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 13 2018
Journal Name
Journal Of Engineering
Zn(II) Removal from Wastewater by Electrocoagulation/Flotation Method using New Configuration of a Split-Plate Airlift Electrochemical Reactor
...Show More Authors

In this paper, split-plate airlift electrochemical reactor as an apparatus with new configuration for wastewater treatment was provided. Two aluminum plates were fixed inside the reactor and present two functions; first it works as split plates for internal loop generation of the airlift system (the zone between the two plates acts as riser while the other two zones act as downcomer) and second it works as two electrodes for electrocoagulation process. Simulated wastewater contaminated with zinc ions was used to test the performance of this apparatus for zinc removal by studying the effect of different experimental variables such as initial concentration of zinc (50-800 ppm), electrical current density (2.67-21.4 mA/cm2), init

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 23 2022
Journal Name
Dental Hypotheses
Remineralization of Dentine Caries Using Moringa Oleifera Based Nano-Silver Fluoride: A Single-Blinded, Randomized, Active-Controlled Clinical Trial
...Show More Authors

View Publication
Scopus (10)
Crossref (4)
Scopus Clarivate Crossref