Doppler assessment may lead to intervention that reduces the risk of fetal brain damage. Aim of thestudy: to assess the relation between ultrasonic hemodynamic Doppler indices of middle cerebral and umbilical arteries (PI, RI), growth indices to immediate neonatal outcomes (weight, head & abdominal circumference, APGAR scores at 1 and 5 minutes and neonatal unit admission) in women with mild, moderate and severe anemia during pregnancy. Present study is a clinical prospective study carried out in Al-Elwiya Maternity Teaching Hospital during (January-Jun) 2019, all anemic pregnant women presented to Obstetrical wards in hospitals for emergency cesarean section were the study population. The final sample selected was 120 pregnant women. Ultrasound Doppler velocimetry measurements like middle cerebral artery-peak systolic velocity (MCA-PSV), middle cerebral artery-pulsatility index (MCA-PI), middle cerebral artery-resistance index (MCA-PR), umbilical artery-pulsatility index (UA-PI), umbilical artery- resistance index (UA-RI), middle cerebral artery to umbilical artery- resistance index ratio (MCA/UA-RI) and middle cerebral artery to umbilical artery- pulsatility index ratio (MCA/UA-PI) were measured. Neonates with less than7had low vital activities (appearance, pulse, grimace, activity, and respiration). Mean MCA-PI of anemic pregnant women with severe anemia was 1.4ms which was significantly lower than pregnant women with mild and moderate anemia, also mean MCA/UA-PI of anemic pregnant women with severe anemia was significantly lower than mild and moderate anemia with p-value <0.001. as well as the Mean neonatal HC of anemic pregnant women with severe anemia 30 cm which was significantly lower than HC of pregnant women with mild and moderate anemia (p=0.04), also mean neonatal AC of pregnant women with mild, moderate and severe, Current study showed no statistical difference in Apgar scores between the studies group, The validity results of MCA/UA-PI ratio regarding neonatal HC of anemic pregnant women are Sensitivity (22.2%), specificity (41.7%). Severe maternal anemia is found significantly associated with abnormal Doppler study middle cerebral artery to umbilical artery pulsatility index. so Doppler middle cerebral artery to umbilical artery pulsatility index has limited validity in the prediction of neonatal outcomes in anemic pregnant women.
Real Time Extended (RTX) technology works to take advantage of real-time data comes from the global network of tracking stations together with inventor locating and compression algorithms to calculate and relaying the orbit of satellite, satellite atomic clock, and any other systems corrections to the receivers, which lead to real-time correction with high accuracy. These corrections will be transferred to the receiver antenna by satellite (where coverage is available) and by IP (Internet Protocol) for the rest of world to provide the accurate location on the screen of smartphone or tablet by using specific software. The purpose of this study was to assess the accuracy of Global Navig
Pots experiment was conducted at the greenhouse of botanical garden belong to Department of Biology, College of Education for Pure Science, Ibn-AL-Haithum, University of Baghdad, for growth season 2018-2019. The aim of the experiment was to study the effects of foliar application of a-tocopherol concentrations (0, 50, 100, 150, 200 mg.L-1) on growth parameters and the activity of some antioxidant enzymes of wheat plant irrigated with sodium chloride concentrations (0, 75, 150, 225) mM.L-1. Salinity reduced plant growth parameter, plant height, flag leaf area, flag leaf chlorophyll content and increased the activity of antioxidant enzymes, superoxide dismutase and peroxidase. Plant growth parameters were enhanced by foliar application of a-t
... Show MoreThis paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol
... Show MoreThis study aimed at evaluating the torsional capacity of reinforced concrete (RC) beams externally wrapped with fiber reinforced polymer (FRP) materials. An analytical model was described and used as a new computational procedure based on the softened truss model (STM) to predict the torsional behavior of RC beams strengthened with FRP. The proposed analytical model was validated with the existing experimental data for rectangular sections strengthened with FRP materials and considering torque-twist relationship and crack pattern at failure. The confined concrete behavior, in the case of FRP wrapping, was considered in the constitutive laws of concrete in the model. Then, an efficient algorithm was developed in MATLAB environment t
... Show MoreIn this work, spinel ferrites (NiCoFe2O4) were prepared as thin films by dc reactive dual-magnetron co-sputtering technique. Effects of some operation parameters, such as inter-electrode distance, and preparation conditions such as mixing ratio of argon and oxygen in the gas mixture, on the structural and spectroscopic characteristics of the prepared samples were studied. For samples prepared at inter-electrode distance of 5 cm, only one functional group of OH- was observed in the FTIR spectra as all bands belonging to the metal-oxygen vibration were observed. Similarly, the XRD results showed that decreasing the pressure of oxygen in the gas mixture lead to grow more crystal planes in the samples prepare
... Show MoreWe studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1
... Show MoreA novel planar type antenna printed on a high permittivity Rogers’ substrate is proposed for early stage microwave breast cancer detection. The design is based on a p-shaped wide-slot structure with microstrip feeding circuit to eliminate losses of transmission. The design parameters are optimized resulting in a good reflection coefficient at −10 dB from 4.5 to 10.9 GHz. Imaging result using inhomogeneous breast phantom indicates that the proposed antenna is capable of detecting a 5 mm size cancerous tumor embedded inside the fibroglandular region with dielectric contrast between the target and the surrounding materials ranging from 1.7 : 1 to 3.6 : 1.
Azo dyes like methyl orange (MO) are very toxic components due to their recalcitrant properties which makes their removal from wastewater of textile industries a significant issue. The present study aimed to study their removal by utilizing aluminum and Ni foam (NiF) as anodes besides Fe foam electrodes as cathodes in an electrocoagulation (EC) system. Primary experiments were conducted using two Al anodes, two NiF anodes, or Al-NiF anodes to predict their advantages and drawbacks. It was concluded that the Al-NiF anodes were very effective in removing MO dye without long time of treatment or Ni leaching at in the case of adopting the Al-Al or NiF-NiF anodes, respectively. The structure and surface morphology of the NiF electrode were inves
... Show More