Isatin is a heterocyclic molecule that belongs to one of the most important classes of organic compounds known as indolines. Isatin, isatin analogs, and their Schiff bases have recently attracted a lot of attention in medicinal chemistry. Isatin, itself, shows various biological activities such as antiviral, anticancer, antimicrobial, anti-inflammatory, analgesic, antioxidant, and anticonvulsant. Bis- Schiff bases containing isatin moiety have been known to possess a wide spectrum of pharmacological activities. This review offers up-to-date information on the most active isatin bis-Schiff bases, which would include anticancer, antimicrobial, antiviral, anticonvulsant, anti-inflammatory, and analgesic activities. These observations c
... Show MoreIsatin is a heterocyclic molecule that belongs to one of the most important classes of organic compounds known as indolines. Isatin, isatin analogs, and their Schiff bases have recently attracted a lot of attention in medicinal chemistry. Isatin, itself, shows various biological activities such as antiviral, anticancer, antimicrobial, anti-inflammatory, analgesic, antioxidant, and anticonvulsant. Bis- Schiff bases containing isatin moiety have been known to possess a wide spectrum of pharmacological activities. This review offers up-to-date information on the most active isatin bis-Schiff bases, which would include anticancer, antimicrobial, antiviral, anticonvulsant, anti-inflammatory, and analgesic activities. These observations c
... Show MoreA new metal complexes are made from the ligands derived from amoxicillin based Schiff's base coordinated with Pd(II) and Co(II) have been synthesized and characterized via different spectroscopic methods. FT-IR spectroscopy have shown a formation of tetrahedral and square planar geometry for Co(II) and Pd(II) complexes, respectively. Surface morphology was inspected via field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM). The Brunauer–Emmett–Teller surface area of the metal complexes samples is about 6.63 to 8.71 m2/g, with pore diameters and volume of 0.030–0.0501 cm3/g and 18.39–22.98 nm, respectively. The quadrupo
The present study employed the NAG-4SX3-3D analyzer to precisely measure the energy response of the sensor. The goal was to enhance the understanding of this technology by providing expert information about the device. This technology offers an economical, quick, accurate, and sensitive approach. By utilizing the turbidity method, Cyproheptadine hydrochloride (CPH) was quantified in pharmaceutical samples without the need for additional substances. CPH is expected to undergo a direct reaction with calcium hexacyanoferrate, resulting in the formation of white precipitates. The linear range for CPH measurement falls within the range of (0.008–30) mM. The relative standard deviation (RSD) for six repetitions at concentrations of (6 and
... Show MoreBackground: The base of the denture is largely responsible for providing the prosthesis with retention, stability, and support by being closely adapted to the oral mucosa. However; the process of bone resorption is irreversible and may lead to an inadequate fit of the prosthesis; this can be overcome by relining. Materials and methods: Acrylic based soft denture liner is prepared by preparing polymer from purified methylmethacrylate monomer with (10-2) initiator and (30%) dibutylphthalate plasticizer concentrations. Biological properties were evaluated in comparison with the control material through subcutaneous specimens' implantation in the New Zealand rabbits. Excisional biopsies were taken after (1, 3, days 1, 2, 3, 4 weeks) period. Mic
... Show More
... Show MoreThis paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure
... Show More